What was found
FOUND DAMAGED WIRES AT APPROX STATION 1615 UNDER FLOOR PANELS. PICTURES HAVE BEEN POSTED ON RVI SITE. APPROX 3 DOZEN WIRES DAMAGED, OF THESE APPROX 2 DOZEN TWISTED RYB WIRES BURNT THRU, REMOVED TIES & LACING CORD, APP 5 FT ALONG W5081 BUNDLE, PNL, ALONG RT SIDE OPENED UP TO E17 RACK & DISC S (P39 PNL). HARNESS LACED & TIED FROM PREV SEQ APP 3 MORE FEET ALONG RT SIDE OF FLOOR, WILL NEED LACE & SECURING OF REMAINING BUNDLE, PER GNMM SHOULD BE SECURED MIN OF 2 FT WITH STANDOFFS. FINISHED LACING AND INSTALLED CLAMPS AND 2 LOCATION IN BUNDLE.