What was found
TURB CASE COOL HPT L LEFT ENGINE HIGH PRESSURE TURBINE (HPT) CASE COOLING ACTUATOR IS STUCK OR REVERTED TO ITS FAILSAFE POSITION. ITEM ROLLED FORWARD. MSG-7550681 INACTV DC INTER MSG-7560661 ACTIVE DC HARD MSG-7550661 INACTV DC MODE MSG-7550661 INACTV DC MODE MSG-7560681 INACTV ER INTER IAW MEL 7524J. WIRES IN ELECTRICAL CONNECTOR DM 75004 HAVE BEEN MOVED IN ACCORDANCE WITH MEL 75020 MAINTENANCE INSTRUCTIONS & MUST BE REPLACED WHEN HPT TURBINE CASE COOLING SYSTEM IS REPAIRED.