What was found
RT ENG FIRE LOOP 1 STATUS MESSAGE. T/S IAW FIM 26-11 FT 804, FOUND WIRE AT FIRE LOOP TERMINAL DISCONNECTED. INSTALLED NEW TERMINAL IAW SWPM 20-30-11. PERFORMED FIRE LOOP TEST IAW AMM 26-11-00, SYSTEM TEST NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT ENG FIRE LOOP 1 STATUS MESSAGE. T/S IAW FIM 26-11 FT 804, FOUND WIRE AT FIRE LOOP TERMINAL DISCONNECTED. INSTALLED NEW TERMINAL IAW SWPM 20-30-11. PERFORMED FIRE LOOP TEST IAW AMM 26-11-00, SYSTEM TEST NORMAL.