What was found
RH ENGINE FIRE LOOP 2 STATUS MESSAGE (ENGINE FIRE DETECTION SYSTEMS, DETECTION LOOPS (ER RESTRICTED 120)).(<P>TRANSFERRED TO MDDR #125715 IAW MEL 26-11-01-01, CAT "C", DUE DATE 23MARCH20. PLACARD INSTALLED. NOTE: RESTRICTED TO ETOPS 120, DISP : DD @ 0013Z.</P><P>LP <SPAN>1120032: </SPAN><SPAN>TIGHTENED LOOSE CONNECTOR ON RH ENG LEFT AFT SIDE. FIRE WARNING SYS TESTS OK PER AMM 26-11-00 . MDDR 125715 CLEARED.</SPAN></P>)