APU FAULT ON START UP.(<P>OPS CHECKED IAW FIM 49-11 FT 958. NO FAULTS NOTED AT THIS TIME. APU STARTED ON FIRST START. PERFORMED 3 SUCCESSFUL STARTS. PERFORMED VISUAL OF APU AREA. NO DEFECTS NOTED. TRANSFERRED TO MDDR 128259 IAW MEL 49-11-01A, CAT 'C', DUE 22MAY20. </P><P>LP 1149831: PERFORMED FIM 49-11 FT 958. NO FAULTS FOUND. APU STARTED 6 TIMES CONSECUTIVELY WITHOUT ISSUE. PERFORMED BITE CHECK ON ECU IAW AMM 49-61-05. NO FAULTS FOUND. OPS CHECKED GOOD. THIS CLEARS DMI 128259. PLACARDS REMOVED. MCC NOTIFIED. T&I RS 13:48Z.</P>)