What was found
APU FAULT EICAS ON FIRST START ATTEMPT. APU STARTED ON 2ND ATTEMPT. PERFORMED APU ECU BITE TEST PER AMM 49-61-05-742-027. TEST OK. OPS TEST NORMAL. APU START WAS NORMAL. NO FAULT MSGS AT THIS TIME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU FAULT EICAS ON FIRST START ATTEMPT. APU STARTED ON 2ND ATTEMPT. PERFORMED APU ECU BITE TEST PER AMM 49-61-05-742-027. TEST OK. OPS TEST NORMAL. APU START WAS NORMAL. NO FAULT MSGS AT THIS TIME.