APU FAILED TO START TWICE, AFTER LANDING. EGT REACHED 780 DEGREES AND RPM HUNG AT 30%, APU FAULT EICAS MESSAGE. FOUND BATTERY AT 37 AMPS, REMOVED AND REPLACED THE BATTERY IAW AMM 24-31-05. REMOVED AND REPLACED THE APU ECU IAW AMM 49-61-05. OPS CHECKED NORMAL.