What was found
INSPECTION TYPE: ETOP, DIVERTED DUE TO EICAS MSG, L/E SLAT ASYM DISPLAYED, L/E LIGHT ILLUM WITH FLAP LEVER UP. EICAS MSG ILLUMINATED MULTIPLE TIMES. PSEU BITE TEST CARRIED OUT IAW FIM 32-09-03. OUTBOARD N010 PROX SENSOR 296 INDICATES INOP, PROX SENSOR REPLACED AND TESTED IAW AMM 27-88-01.