Service difficulty report · Connector · Boeing 72751C

Difficulty date
July 10, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N904UP
Make and model
Boeing 72751C
Aircraft serial
18946
Part
Connector
Condition
Chafed
Location
Nr 3 Engine
Stage of operation
LD
Nature of condition
N
Precautionary procedure
E

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INSPECTION TYPE N/A, ENG 3 STRUT OVERHEAT LIGHT CAME ON JUST PRIOR TO LANDING. EXTINGUISHED AFTER ENGINE WAS SHUT DOWN. ENGINE SHUTDOWN DURING LANDING ROLL. *S/D* REPAIRED CHAFED WIRE AT FIRE WALL. REMOVED AND REPLACED CONNECTOR ON START STRUT, CONNECTOR ON START STRUT OVERHEAT 1OO DEG IN AFT AIRSTAIR AREA AND OPS CK NORMAL.

More about the Boeing 727-51C