What was found
RECIRC FAN FAULT STATUS MESSAGE FOLLOWED BY BURNING RUBBER SMELL. TROUBLE SHOT RECIRC FAN FAULT STATUS MESSAGE "RECIRC FAN 2, FAILED WIRING/LOW FAN SPEED" IAW CRJ 900 FIM 21-22-10-810-802-A02. REMOVED AND REPLACED RT RECIRC FAN IAW CRJ 900 AMM 21-22-10-000/400-801-A01. OPS CHECK GOOD.