What was found
CORROSION SEVERAL PLACES ON ANGLE MOUNTTING BTW FS=319 TO FS= 379 ON SURROUND STRUCTURE AT GALLEY SERVICE DOOR. CORROSION SEVERAL PLACES ON ANGLE MOUNTTING BTW FS=319 TO FS= 379 ON SURROUND STRUCTURE AT GALLEY SERVICE DOOR DUE TO EXCESSIVE DAMAGE FOUND OUT OFF LIMITS PER CRJ 900 SRM 53-21-23-101-002-A02 AND WAS REPLACE PER CRJ900 SRM 53-21-23-101-002-A02, 51-42-06-001-001-A01 AND 51-42-21-001-001-A01