As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT WINDSHIELD HEAT CAUTION, BURNING SMELL ASSOCIATED WITH MSG, PERFORMED INSTALLATION OF THE RT WINDSHIELD IAW AMM 56-11-01-400-801-A01-PSA. PERFORMED AN OPERATIONAL TEST OF THE WINDSHIELD/SIDE WINDOW TEMPERATURE CONTROLLER IAW AMM 30-41-06-710-801-A01. THE OPS TEST WAS SATISFACTORY. PERFORMED A WINDSHIELD LEAK TEST BY PRESSURIZING THE AIRCRAFT USING THE APU FOR MAINTENANCE IAW AMM 21-31-00-910-801-A01-PSA. NO LEAKS WERE FOUND. THIS ACTION CLEARED THE MEL, AND THE PLACARD REMOVED.