Service difficulty report · Connector · Emb ERJ190100IGW

Difficulty date
December 9, 2012
Submitted
December 10, 2012
Operation
Air carrier
Aircraft
N206JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000025
Aircraft time
18,576 hours, 11,488 cycles
Part
Connector
Condition
Corroded
Location
Te Flap
Stage of operation
AP
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 1226 RDU-BOS, CREW DECLARED EMERGENCY DUE TO "FLAP FAIL" EICAS WHEN FLAP 1 SELECTED FOR APPROACH. DID NOT RESET AFTER QRH. LANDED FLAPS "0" PER QRH PROCEDURE. DURING TROUBLESHOOTING FOUND CONNECTOR P1250 CORRODED AT RIGHT O/B FLAP SKEW SENSOR T4. REMOVED AND REPLACED CONNECTOR P1250 AS PER SWPM 20-31-04, PERFORMED OPERATIONAL CHECK AND RIGGING AS PER MM 27-50-00, OPS CHECK OK AT THIS TIME.

More about the Emb ERJ 190-100 IGW