What was found
DURING HEAVY MAINTENANCE, CRACK ON RH WING FIXED LEADING EDGE SKIN AT SLAT TRACK # 5 CUTOUT; REF TOMX NR 00006 WO 1965) HFEC INSPECTION WAS ACCOMPLISHED ON RH WING FIXED LEADING EDGE SKIN AT SLAT TRACK # 5 CUTOUT. ONE CRACK WAS FOUND AND DELIMITED WITH A MEASURE OF 0.562IN LENGTH PER EMB190/195 NDT MANUAL PART 1, 51-00-00 TASK 51-00-00-916-803-A SECTION WITH CRACK WAS CUT OUT ON RH WING FIXED LEADING EDGE SKIN AT SLAT TRACK # 5 PER EMB190 SRM 57-49-01/REPAIR. THE MEASUREMENT WAS PERFORMED AFTER CUTTING THE LEATHER OF THE ATTACK EDGE FIXED LOCATED ON RH WING FIXED LEADING-EDGE SKIN AT SLAT TRACK #5, WITH A DIMENSION OF 10.600" THEREFORE IT IS WITHIN LIMITS PER EMB190 SRM 57-49-01/REPAIR 51P PAR 4 FIG 201.51 ITEM 3 AND 4.D FIGURE 201. (SUPPLEMENTAL INFORMATION ADDED TO THE ATA CODE)