What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON LOWER INB FASTENER HOLE DOOR STOP FITTING #1 FR 68 LH. CRACK DIRECTION 12 OCLOCK. CRACK D= 0.160 INCH; REF AEROMAN WO 2025 187/1 NR 2025-367243 PERFORMED PERMANENT REPAIR LOCATED ON FRAME 68, LT SIDE AT LEVEL OF DOOR STOP #1 IAW SRM 53-41-12-300-011. THIS REPAIR IS CATEGORY B, FOR AREA 1 AND 3 INSPECTION THRESHOLD FROM TIME OF ADL / REPAIR EMBODIMENT 60000 FC (FH NOT RELEVANT), SUBSEQUENT INSPECTION INTERVALS TBD, INSPECTION METHOD TBD, IAW SRM 53-41-12-205-010, TABLE 6.