What was found
SWF - FLT 533 - DURING FLIGHT, THE LANDING GEAR HANDLE WOULD NOT GO UP. HORN SOUNDED AFTER FLAPS RETRACTED. RETURNED TO SWF. VERIFIED OPERATION OF AIR/GROUND SENSOR LOGIC SYSTEM, LANDING GEAR SAFETY SENSOR, LOCKS AND CABLE. ALL WORK PERFORMED IAW B MM 32-31-21, 32-09-200, 32-09-1. NO DISCREPANCY FOUND. EVALUATION FLIGHT REQUIRED PER DIRECTOR OF MAINTENANCE. EVALUATION FLIGHT WAS SATISFACTORY. POST-FLIGHT VISUAL INSPECTION C/W, NO DISCREPANCIES NOTED. (X)