Service difficulty reports
1,773,593 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202504285496Door Latch · obstructedAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR DIFFICULT TO OPEN. DOOR HANDLE WILL NOT OPEN DOOR WHEN TWISTED TO THE RIGHT.. TWISTING LEFT THE DOOR OPENS NORMAL. MAINTENANCE CHECKED AND FOUND SMALL FASTENER LODGED IN CENTER LATCH OF FLIGHT DECK DOOR, REMOVED FASTSDR AALA202504282588Battery · no testAIRCRAFT WAS NOT GROUNDED: FORWARD MEGAPHONE INOPERATIVE. REPLACED BATTERIES IN FORWARD MEGAPHONE AND ACCOMPLISHED A SATISFACOTRY OPERATIONAL CHECK AMM 25-65-51.SDR QXEA2025042800164Lever · faultedDOOR L-2 ARMING LEVER WON'T GO FLUSH WITH HANDLE. REMOVED FROM SERVICE. REMOVED AFT PASSENGER DOOR LINING (UPPER) REF. AMM TASK 25-23-05-000-801-A, PAE 1-5, 6K-. FOUND ADJUSTABLE TOGGLE LINK FOR "ARMED" FLAG OUT OF ADJUSTMENT CAUSING HANDLE TO NOT BE FLUSH. SDR DALA2025042803293Access Door · open(LOG 7063600) ON INITIAL CLIMBOUT, THE LANDING GEAR LEVER WAS UP, BUT LANDING GEAR WAS STILL DOWN. RAN THE QRH AND WE WERE ABLE TO PUT THE GEAR UP. DE-BRIEFED FLIGHT CREW, SUSPECT MAN GEAR EXT ACCESS DOOR WAS OPEN. AFTER DOOR WAS CYCLED WHEN QRH CHECKLIST WAS SDR DALA2025042803294Battery Pack · no test(LOG 7046244) FOUND LEFT AFT EMERGENCY LIGHTS INOP ON SVC CK. REMOVED AND REPLACED BATTERY PACK AND CHARGER AT LOCATION M1673 IAW B737 AMM 33-51. EMERGENCY LIGHT OPS CK GOOD.SDR DALA2025042803292Intercostal · corroded(LOG 0932659) SIGN OF CORROSION ON SCREWS HOLES RH SIDE FWD OF R2 DOOR. REMOVED AND REPLACED INTERCOSTAL AT MAIN CABIN ON R/H SIDE FWD OF R2 DOOR IAW B 737 SRM 51-40-02. REMOVED AND REPLACED INTERCOSTAL AT MAIN CABIN ON R/H SIDE FWD OF R2 DOOR IAW B 737 SRM 51SDR DALA2025042803289Intercostal · corroded(LOG 0932149) CORROSION WEB - INTERCOSTAL LOCATED BS787 TO BS 794 AND AT LEVEL STR25 R AFT CARGO COMPARTMENT. REPLACED WEB - INTERCOSTAL AND FASTENERS LOCATED BS 787 TO BS 794 AND AT LEVEL STR25R AFT CARGO COMPARTMENT AS PER B737-800 SRM 51-10-02-0G ITEM 9, SRSDR DXTA2025042803220Lift Strut · inoperativeMAIN DOOR HARDWARE: HARWARE FELL OUT OF DOOR STRUT CORRECTIVE ACTION: TECHS FOUND HARDWARE TEMP INSTALLED ON MED DOOR STRUT. REMOVED HARDWARE AND CHECKED FOR ANY DAMAGE OR DEFECTS WITH NONE NOTED. CONFIRMED PARTS ON ORDER AND CORRECT REPLACEMENT PARTS AND TEMPSDR DXTA2025042803216Adc · malfunctionedBOTH ON ADC 2 AMBER CAS: RECEIVED BOTH ON ADC2 MESSAGE AFTER TAKEOFF. SELECTED LEFT SIDE TO ADC 1 AND IT REVERTED BACK TO ADC2. MESSAGE REMAINED THROUGH OUT LANDING AND POWER DOWN. CORRECTIVE ACTION: REMOVED AND REPLACED #1 ADC AS REQUIRED. PERFORMED OPS CHECKSDR DXTA2025042803221Battery · inoperativeEMERGENCY LIGHTING: BATTERIES DO NOT STAY CHARGED OVERNIGHT. CORRECTIVE ACTION: DURING FIRST POWER ON CHECKS FOUND EMERGENCY LIGHTS OPERATIONAL WITH NO ISSUES. GPU WAS THEN CONNECTED AND TURNED ON, CHARGED EMERGENCY LIGHTING FOR ABOUT 2 HOURS WITH NO DEFECT NOSDR DALA2025042803285Bracket · mislocatedSHIP 3407 WIRE BUNDLE BRACKET'S (2) ON FR 64 BETWEEN STGR 1L/1R IS NOT LOCATED IN THE CORRECT POSITION PER DRAWING. CORRECTIVE ACTION: CORRECTED PER NON-ROUTINE 86 IN THE WORK PACKAGE. (0933271)SDR DALA2025042803283Cover · openSHIP 3329 SEAT 41 A B REPORTED OVERHEAD O2 COVER OPENED THREE TIMES IN FLIGHT. MASKS DID NOT FALL OUT. PASSENGER CLOSED OVERHEAD EACH TIME. REPORTED AFTER BLOCK IN. CORRECTIVE ACTION: RE-PACKED MASKS AND SECURED PANEL PER A330 AMM 35-23. OK FOR SERVICE. (70805SDR DALA2025042803280Bottle · low pressureSHIP 3417 2R CHECK DOOR PRESSURE CAUTION. CORRECTIVE ACTION: SERVICED DOOR BOTTLE PER A330 AMM 52-15. OK FOR SERVICE. (4284472)SDR JJBA20250428068Light · misinstalledRH OVERWING EMERGENCY EXIT LIGHT INSTALLED UPSIDE DOWN. REMOVED AND REPLACED RH OVERWING EMERGENCY EXIT LIGHT HOUSING.SDR AALA202504287053Floorboard · delaminatedAIRCRAFT IN BASE MAINTENANCE: DURING WALK THROUGH OF CABIN FOUND DELAM ON THE CABIN FLOOR BOARD BETWEEN SEATS 14C & 14D. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR AALA202504288189Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: DELAMINATED FLOOR PANEL 241FF CABINA C. MAINTENANCE REPAIRED FLOOR PANEL 241FF CABINA C. I.A.W B777-200 SRM 53-00-50-2R PROCEDURE 10 REPAIR 10.SDR AALA202504282572Lamp · burned outAIRCRAFT IN BASE MAINTENANCE: BURNED LAMP ON LATERAL EXIT SIGNS ON 3R CABIN DOOR. FINAL REPAIR UPDATED: REPLACED LAMP ON LATERAL EXIT SIGNS ON 3RCABIN DOOR IAW AMM 33-51-01-960-801.SDR CNMA202504280002Regulator · leakingAT 10,000 MSL, CREW O2 QTY DROPPED TO 70 PSISDR BAGA2025042800004Line · brokenR ENG FIRE MESSAGE IN FLIGHT. ENGINE SHUTDOWN AND 1 BOTLE DEPLOYED. PERFORMED INSPECTION AND FOUND NO EVIDENCE OF FIRE ON RH ENGINE. FOUND DAMAGED LINE THAT WAS IN VICINITY OF THE TR FIRE DETECTION LOOP. REPLACED LINE, AND REPLACED BLOWN FIRE BOTTLE.SDR DALA2025042803275Indication Sys · inoperativeSHIP 668 1R SLIDE LIGHT DOES NOT COME ON WHILE ATTEMPTING TO ARM THE DOOR. CORRECTIVE ACTION: CHECKED, CLEANED AREA, OPS GOOD PER B757 AMM 52-15. (7037314)SDR DALA2025042803274Proximity Switch · out of adjustSHIP 688 4L DOOR SLIDE ARM LIGHT INOP. CORRECTIVE ACTION: T/S PER B757 AMM 25-66. CLEANED AND ADJUSTED PROX SWITCH/TARGET ON 4L DOOR. CKS OK. MEL/PLAC RMVD. (7025358)SDR DALA2025042803273Not Reported · not reportedSHIP 6712 DTA MONITOR INSPECTION LOG REF ERA 625721-14 FUSELAGE / FRAME STA 540 / BTW S-24L & S-25L / DENT. CORRECTIVE ACTION: REF ERA 625721-14AD. (0933209)SDR DALA2025042803272Support · crackedSHIP 6710 CRACK ON SUPPORT STRUCTURE (2 EAS) ON STA 418 TO STA 460 OVER S24L AT E&E BAY. CORRECTIVE ACTION: SUMMARY OF NRC 00357. SUPPORT STRUCTURE ON STA 460 OVER S24L AT E&E BAY WAS REPAIRED PER PRI 625765-14 REV 0, ER/A 625765-14 REV ORIGINAL SECTION I: REPSDR DALA2025042803271Floorbeam · corrodedSHIP 6712 CORROSION AND PREVIOUS BLENDS FOUND ON CABIN FLOOR SUPPORT BEAM UPPER SURFACE TRANSITIONING TO THE LOWER SURFACE OF THE TOP FLANGE @ STA 1640 LBL 15 TO RBL 12. RED STREAMER AND TAG # 14361 ATTACHED. CORRECTIVE ACTION: REMOVED AND REPLACED NEW FABRICASDR HNAA2025042800223Fan · failedLH SIDE ROW 4 THRU 6 HAD SMOKE. TURNED OFF RECIRC FAN AND SMOKE CLEARED. PERFORMED OPS CHECK OF AIR DISTRIBUTION SYSTEM IRW AMM 21-20-00 RAN PACK 1 AND 2 FOR 1 HOUR NO SMOKE OR SMELLS NOTED. OPS CHECK GOOD AT THIS TIME.SDR HNAA2025042800222Charger · inoperativeLH WING FWD EMERGENCY LIGHT INOP. RAR CHARGER IAW AMM 33-50-04. OPS CHECK GOODSDR CALA2025042804286Control Lever · faultedFMC INDICATED 212/FLAP BUT FLAPS WERE UP. ACFT SPEED WOULD NOT A CCERATE. INTERROGATED FSEU. LAST LEG O. MSG # 27-51417. FLAP LVR SENSOR. TROUBLSHOT PER FIM 27-51 TASK 811 AND 27-51 TASK 801.FOUND NO EXISTING FAULT , IN FAULT HISTORY LEG 0 FOUND MAINT MSG # SDR CALA2025042804284Warning Message · false activationDOOR WARNING ANNUNCIATOR IS ON EQUIP LIGHT ILLUMINATED INFLIGHT. PRESSURIZATION REMAINS NORMAL. PERFORMED FIM TASK 52-10 TASK 802, PERFORMED PSEU OPS CK IAW MM TASK 32-09-10-710-801.NO FAULTS DETECTED AFTER RUNNING TEST.NO FURTHER MX ACTION REQ.OK TO CONTSDR CALA2025042804281Slide · no discrepancyREMOVED R2 DOOR-MOUNTED EMERGENCY ESCAPE SLIDE FOR SHEETMETAL REPAIR ( L/P 4610153) REF AMM 25-66-01. R2 DOOR-MOUNTED EMERGENCY ESCAPE SLIDE, UPDATED FOR RII REQUIREMENT. REMOVED AND REPLACED R2 DOOR SLIDE PACK TO FACILITATE MX, DISARMING PIN REMOVED AND STOWESDR CALA2025042804280Slide · no discrepancyFA REPORTS 1R DOOR SLIDE LOOKS ABNORMAL IN ARMED POSITION R1 DOOR IS WITHIN LIMITS PER AMM TASK 25-66-01-200-802.SDR CALA2025042804279Bottle · noneDISARMING OF THE STRIKER LEVER OF THE DOOR DAMPER AND EMERGENCY OPERATION CYLINDER TO FACILITATE SLIDE REMOVAL R1 PASSENGER DOOR REF. FIG 52-10-00-991-00300-B - REARMED STRIKER LEVER FOR THE DOOR DAMPER AND EMERGENCY OPERATION CYLINDER. SAFETIED PER AMM MED DOSDR CALA2025042804275Pin · installedINSTALLED SAFETY PIN IN THE INFLATION CYLINDER VALVE ON R2 DOOR SLIDE. REF AMM 25-66-01-000-801. REF. AMM 25-66-01-400-801 REMOVED SAFETY PIN FROM THE INFLATION CYLINDER VALVE ON THE R1 DOOR (NOT THE R2 DOOR). C/W GMM 09-25-05 RII FOR INSTALLATION OF R1 DOOR ESDR CALA2025042804274Slide · no discrepancyREMOVED R1 DOOR ESCAPE SLIDE PACK AND COVER FOM REF AMM 25-66-01-000-801. REINSTALLED R1 DOOR ESCAPE SLIDE PACK AND COVER AFTER FOM. REF. AMM TASK 25-66-01-400-803. C/W GMM 09-25-05 RII FOR INSTALLATION OF R1 DOOR ESCAPE-SLIDE-PACK AND COVER REF AMM 25-66-01-4SDR CALA2025042804266Skin · crackedEXTERNAL GROUND POWER DOOR CUTOUT HAS GOUGE AT AFT CENTER SECTION. ACCOMPLISHED REPAIR AT EGPR AFT CENTER SECTION IAW SRM 53-10-15-2R-4. SFR NO. 805.SDR CALA2025042804258Battery Pack · no testEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - FIRST CLASS FLOOR PATH LIGHTING DOES COME ON BUT GOES OUT AFTER APPROXIMATELY 20 SECONDS. THE AIRFRAFT HAS BEEN RUNNING FOR 5 HOURS ON APU POWER. NO IMPROVEMENT IN TEST DURATION. REMOVED & REPLACEDSDR CALA2025042804257Light · inoperativeFOUND WINDOW LIGHT AT RH EMERGENCY EXIT INOP PERFORMED REPLACEMENT OF WINDOW LIGHT - OVERWING EXIT LIGHT ASSEMBLY IAW AMM TASK 33-21-00-960-802, OPS CHECK OK.PARTS USED: 60-3321-3-0009, QTY :1SDR CALA2025042804253Unknown · leakingNEAR DOOR 1L GIRT BAR SEWAGE LIQUID LEAKING DIRTY BAD SMELL PERFORMED GV OF DOOR L1 FLOOR DRAINS NO BLOCKAGE FOUND. CLEANERS CLEANED FLOOR AND DRAIN AREA.SDR K11A2025042500315Warning Light · illuminatedON THE RUNWAY CLEARED FOR TAKE-OFF, PER TAKE-OFF, AIRCRAFT WAS NOT MOVING, THROTTLE WAS NOT ADVANCING. CARGO DOOR ARMED LIGHT ILLUMINATED, REJECTED THE TAKE-OFF AND ADVISED TOWER NEEDED TO EXIT RUNWAY. WHEN EXCITED THE RUNWAY AND SET THE PARKING BRAKE THE LIGHSDR 2025FA0000332Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, JUST AFT OF FR75 LH SIDE Z SECTION FOUND WITH CORROSION (LEVEL 2).SDR 2025FA0000331Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, -Y794.3 (RH SIDE) FROM FR72 TO FR80 FOUND MULTIPLE SPOTS OF CORROSION (LEVEL 2).SDR 2025FA0000330Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, -Y450 (RH SIDE) FROM FR75 TO FR78 FOUND MULTIPLE SPOTS OF CORROSION (LEVEL 2).SDR 2025FA0000329Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, -Y450 (RH SIDE) FROM FR75 TO FR80 FOUND MULTIPLE SPOTS OF CORROSION (LEVEL 2).SDR 2025FA0000327Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, -Y450 (RH SIDE) FROM FR75 TO FR70 FOUND MULTIPLE SPOTS OF CORROSION (LEVEL 2).SDR 2025FA0000326Floor Support · corrodedMAIN DECK FLOOR STRUCTURE, -Y450 (RH SIDE) FROM FR75 TO FR78 FOUND MULTIPLE SPOTS OF CORROSION (LEVEL 2).SDR DALA2025042703266Floor Support · corrodedSHIP 3142 CORROSION FLOOR BEAM -Y1292 LOCATED BTW FR 65 TO FR 66 AT AFT GALLEY AREA (SSI 534147). REPLACED FLOOR BEAM LOC -Y1292 BTW FR64 TO FR66 AT AFT GALLEY AREA AS PER A319 SRM 51-72-11 AND A319 SRM 51-42-11 AND DWG D53472816 RELEASE DATE 18-DEC-06 ISSUESDR DALA2025042703265Floor Support · corrodedSHIP 3142 CORROSION FLOOR BEAM +Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA (SSI 534147). REPLACED FLOOR BEAM Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA ASPER A319 SRM 51-72-11, A319 SRM 51-42-11 AND DWGD53472780 RELEASE DATE: 26-APR-18 SDR DALA2025042703264Plate · crackedSHIP 3142 DISC: CRACK PLATE LOCATED BTW FR 68 TO FR 69 LEVEL STR 23R AT AFT GALLEY AREA. C/A: REPLACED PLATE LOCATED BTW FR 68 TO FR 69 LEVEL STR 23R AT AFT GALLEY AREA AS PER A319 SRM 51-72-11, A319 SRM 51-42-11, DWG D53480505, ISSUE: FE, RELEASE DATE :09-JANSDR DALA2025042703263Fitting · corrodedSHIP 3142 CORROSION CENTER FITTING LOCATED BTW FR 66 TO FR 68 LH SIDE CUT OUT AT AFT GALLEY AREA (SSI 534136). REPLACED CENTER FITTING LOCATED BTW FR 66 TO FR68 LH SIDE CUT OUT AT AFT GALLEY AREA AS PER A319 SRM 51-72-11, A319 SRM 51-42- 11, DWG D53480048, ISDR DALA2025042703262Web · corrodedSHIP 3142 CORROSION UNDERFLOOR STRUCTURE FRAME WEB LOC FR69 TO FR70 AT LEVEL ST R23R AT AFT GALLEY AREA. REPLACED FRAME WEB AND FASTENERS LOCATED FR69 TO FR70 AT LEVEL STR23R AT AFT GALLEY AREA AS PER A 319 SRM 51-42-11 AND DWG: D53474180 RELEASE DATE: 09/SESDR DALA2025042703261Web · corrodedSHIP 3142 CORROSION UNDERFLOOR STRUCTURE FRAME WEB LOC FR69 T0 FR70 AT LEVEL ST R 23L AT AFT GALLEY AREA. REPLACED FRAME WEB AND FASTENERS LOCATED FR69 TO FR70 AT LEVEL STR23L AT AFT GALLEY AREA AS PER A319 SRM 51-42-11 AND DWG: D53474180 ISSUE: AA RELEASE D