Service difficulty reports
1,770,704 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2026092569474Floorbeam · corrodedAFT WET AREA ANGLE STA 990 RBL 40 TO RBL 50 CORRODED. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1, REMOVED AND REPLACED ANGLE IAW B737-800 SRM 51-40-02-0G-0 W: 1" O: .050 R: .016 L: 1" D: .034.SDR REXA2026110402005Lug · corrodedAFTER REMOVING BUSHINGS & BEARINGS, CORROSION & WEAR FOUND ON LUG BORES LOCATED ON AILERON STATIONS 337.034, 342.123, 343.534 & 344.1665 AT RIGHT AILERON FITTINGS. LUGS STATIONS 336.4015 (R1), 337.034 (R2), 342.123 (R4), 343.534 (R5) AND 344.1665 (R6) AT RIGSDR ASAA2026092569396Floor Support · corrodedAFT WET AREA INTERCOSTAL STA 947 TO STA 967 LBL 50 CORRODED GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1. REMOVED AND REPLACED INTERCOSTAL IAW B737-800 SRM 51-40-02-0G-0. W:2" O:0.087" R:0.050" L:2" D:0.037"SDR ASAA2026092569465Web · corrodedAFT WET AREA RT WEB BS 986 - 990, RBL 40 - 50 WAS CORRODED. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1, REMOVED AND REPLACED WEB IAW SRM 51-40-02-0G-0.SDR SWAA2026102985003Floor Panel · pulledFLOOR PANEL 231RF UPPER SKIN HAD AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0.SDR SWAA2026102964264Floor Panel · pulledFLOOR PANEL 231NF UPPER SKIN HAD AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0.SDR SWAA2026102920179Floor Panel · pulledFLOOR PANEL 231FF UPPER SKIN HAD AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1.SDR AALA202610297497Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION CENTER FITTING LOC. LOWER SILL BTW FR66 AND FR68 AT LEVEL S TR23R AT AFT GALLEY AREA, MEASURES ARE: L: 3.170 IN, W: 0.583 IN, D: 0.005 IN. MAINTENANCE REPLACED CENTER FITTING LOC. LOWER SILL BTW FR66 AND FR68 AT LEVEL STSDR SWAA2026102815808Frame · corrodedCORROSION ON FRAME LOCATED BS 951 RBL 54 WL 208.3 AT AFT GALLEY AREA REPAIRED FRAME BS 951 AND BTW STR16R TO STR17R AT RBL 54 WL 208.3 AT AFT GALLEY AREA IAW EA N 26-153-02782-WIP2 AND EA N 26-153-02782. THIS REPAIR IS CLASSIFIED AS MINOR ACTION AND CATEGORY SDR SWAA2026102744861Access Panel · crackedCRACKED BLADE FOR ACCESS PANEL 333AT ON THE LT HORIZONTAL STAB. REPLACED THE BLADE FOR ACCESS PANEL 333AT IAW SRM 51-10-02, ITEM 9, & SRM 51-40-02.SDR SWAA2026102726535Tie Clip · crackedCRACKED TIE CLIP, BS 727C, STRINGER 6R. REPLACED THE TIE CLIP IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, & DWG 146A1103, SHEET 11, REV-.SDR SWAA2026102784791Tie Clip · crackedCRACK TIE CLIP, BS 727E, STRINGER 5R. REPLACED THE TIE CLIP IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, & DWG 146A1112, SHEET 9, REV-.SDR SWAA2026102761176Tie Clip · crackedCRACKED TIE CLIP, BS 767, STRINGER 6L. REMOVED TIE CLIP LOC. STA 767 AND STR 6L AT PASSENGER CABIN IAW SRM 51-40-02 AND PERFORMED DVI ON ADJACENT AREA AND DID NOT FIND MORE DAMAGE. REPLACED THE TIE CLIP IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, & DWG 146A1SDR SWAA2026102799797Tie Clip · crackedCRACKED TIE CLIP, BS 706, STRINGER 3L. REPLACED THE TIE CLIP IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, & DWG 144A1107, SHEET 15, REV-.SDR SWAA2026102778488Tie Clip · crackedCRACKED TIE CLIP, BS 706, STRINGER 4L. REPLACED TIE CLIP IAW SRM 51-40-02, AND DWG 144A1107, SHEET 15, REV-.SDR SWAA2026102741047Channel · crackedCRACKED NUT PLATE CHANNEL INTERNAL CAVITY LEADING EDGE LOCATED OF SS571, RT WING. REPLACED THE NUT PLATE CHANNEL IAW SRM 51-10-02, ITEM 9, & DWG 112A4402, SHEET 13, REV-.SDR SWAA2026102643020Retainer · looseFORWARD ENTRY DOOR SLIDE GIRT BAR RETAINER WAS LOOSE. TIGHTENED THE RETAINER BRACKET IAW AMM 25-66-02-400-801.SDR SWAA2026102675903Retainer · looseAFT ENTRY DOOR SLIDE AFT GIRT BAR RETAINER BRACKET LOOSE. TIGHTENED THE GIRT BAR RETAINER BRACKET IAW AMM 25-66-02-400-801.SDR IPXA2026102228872Support Angle · damagedWHILE REMOVING CREASE BEAM FOUND KICKPLATE SUPPORT ANGLE BETWEEN BS 350 AND STA 358 LT SIDE WITH ELONGATED HOLE AFTER FASTENER REMOVAL. INSTALLED BRACKET KICKPLATE SUPPORT ANGLE, BTW BS 350 AND 358 LT SIDE, IAW 51-40-02-0G-0.SDR ASAA2026092569410Floorbeam · corrodedAFT WET AREA FLOORBEAM BS 986, LBL 20 - LBL 50 FOUND CORRODED. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REPAIRED THE FLOORBEAM IAW SRM 53-70-51-R2-6.SDR ASAA2026092569399Floorbeam · corrodedAFT WET AREA FLOORBEAM STA 947 RBL 10 TO RBL 50 CORRODED. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REPAIRED FLOORBEAM IAW 53-70-51-2R-8.SDR ASAA2026092569398Floor Support · corrodedAFT WET AREA INTERCOSTAL STA 947 TO STA 967 RBL 50 CORRODED. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51-40-02-0G-0.SDR ASAA2026092569397Floorbeam · corrodedAFT WET AREA FLOORBEAM STA 986 RBL 40 TO RBL 50 CORRODED. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1, REPAIRED FLOORBEAM IAW SRM 53-70-51-2R-4.SDR ASAA2026092569394Floor Support · corrodedAFT WET AREA FLOOR SUPPORT BS 967 - 986, LBL 20 CORRODED. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-02-0.SDR ASAA2026092569393Floor Support · crackedFWD WET AREA FLOOR SUPPORT STA 312 TO STA 328 RBL 26 CRACKED. GROUNDED - YES. REMOVED AN REPLACED SUPPORT IAW B737-800 SRM 51-40-02-0G-0.SDR ASAA2026092569392Support · corrodedFWD WET AREA RT CHORD BS 294 - 328 CORRODED. GROUNDED - YES. REMOVED DAMAGE, FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-2, REMOVED AND REPLACED RT CHORD IAW SRM 51-40-02-0.SDR ASAA2026092569391Support · corrodedFWD WET AREA L1 DOOR SCUFF PLATE SUPPORT BS 312 - 344 CORRODED. GROUNDED - YES. REMOVED DAMAGE, FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-1, REMOVED AND REPLACED SUPPORT IAW SRM 51-40-02-0G-0.SDR AALA202610204291Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON THE FORWARD GIRT BAR MOUNT FITTING. MAINTENANCE REPLACED FORWARD GIRT BAR FITTING AT STA 316, STR 17L, LBL 48 IAW AARD 51-00-05-1.SDR HNAA2026101901009Shear Tie · crackedSHEAR TIE ON FR 73 BTWN STRINGERS 8R AND 9R HAD A POSSIBLE CRACK. R & R SHEAR TIE IAW SRM 51-40-02.SDR CALA2026101920445Web · corrodedPOSSIBLE CORROSION ON FWD CARGO WEB DOOR SUROUND. REMOVED AND REPLACED MAIN SILL WEB ON FWD CARGO ENTRY DOOR APPLIED ALODINE AND PRIMER IAW SRM 51-40-02-0G-0, SRM 53-30-15-1A-1, SRM 51-40-08-0G-0, SRM 51-40-0 5-0G-0, AMM 51-21-72-370-804 AND AMM 51-21-72-3SDR AALA202610168661Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION CORNER FITTING LOC. LOWER SILL FR 68 AT LEVEL STR23R AT AFT GALLEY AREA L=1.591IN W=0.476IN D=0.103IN. MAINTENANCE REPLACED CORNER FITTING LOCATED FR 68 AT LEVEL STRG 23R AFT GALLEY AREA, IAW A319 SRM 51-72-11-911-001 ANSDR HNAA2026101601006Support Bracket · cracked57-2558 FLEX LINE CLAMP SUPPORT BRACKET CRACKED ON RH WING TRAILING EDGE RIB 1A. RAR BRACKET IAW SRM 51-40-02SDR AALA202610157103Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO LEFT TRANSITION PANEL CORRODED IN SEVERAL PREVIOUSLY BLENDED AREAS STATION 500+10 TO STATION 500I LBL24. INSTALLED NEW TRANSITION PANEL AND SPLICE PLATE IAW SRM 53-00-53-2R-5 AND AARD 51-00-05-1.SDR SWAA2026100781291Skin · crackedCRACK ON THE EXTERNAL GROUND ELECTRICAL POWER CUTOUT, LOWER AREA. REPAIRED THE EXTERNAL GROUND ELECTRICAL POWER CUTOUT IAW SRM 53-10-15-2R-4, REPAIR 4.SDR AALA202610053658Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: LBL 52 BTW STA 947 AND STA 967 INTERCOSTAL HAS CORROSION. REMOVED AND REPLACED INTERCOSTAL IAW AARD 51-00-05-1.SDR IPXA2026100523567Channel · crackedDURING PERFORM EO-84432-JIC1, FOUND WEDGE CHANNEL CRACK AT L/H STAB BL 421.5.SDR IPXA2026100523556Channel · crackedDURING PERFORM EO-84432-JIC1, FOUND WEDGE CHANNEL CRACK AT RT STAB BL 421.5. PERFORMED THE HEAT TREATMENT FROM O TO T62 CONDITION. IAW SREO-92949-REQ1, REV 1, STEP 5.SDR J7SA2026100500529Coffeemaker · odorBURNING ODOR MOMENTARILY DETECTED FROM GALLEY AC POWER OUTLET AFTER COFFEE MACHINE FAILED. COFFEE MACHINE DISCONNECTED AND AIRCRAFT LANDED WITHOUT INCIDENT. REPLACED KEURIG COFFEE MAKER, OPS CHECK GOOD.SDR QXEA2026100100185Lanyard · misalignedFWD AND AFT O2 BOX ASSY MASK LANYARD FOUND INCORRECTLY ALLIGNED WITH GUIDE TUBE. ADJUSTED OXYGEN GENERATOR ON FWD AND AFT GALLEY OXYGEN BOX ASSY. SO THAT THE MASK LANYARD AND PULL PIN ALLIGN WITH THE GUIDE TUBE. RESECURED GENERATOR TO THE BOX ASSY. REF WORK PSDR QXEA2026100100183Lanyard · misalignedFWD AND AFT GALLEY OXYGEN BOX ASSY MASK LANYARD FOUND INCORRECTLY ALLIGNED WITH GUIDE TUBE. ADJUSTED OXYGEN GENERATOR ON FWD AND AFT GALLEY OXYGEN BOX ASSY SO THAT THE MASK LANYARD ALLIGNED WITH PULL PIN GUIDE TUBE. RESECURED GENERATOR TO BOX ASSY REF CMM 35-2SDR QXEA2026100100179Oxygen Gen · misinstalledFWD ENTRY DOOR AND AFT GALLEY FA OXYGEN GENERATOR INSTALLED INCORRECTLY. REMOVED FA OXYGEN BOX/GENERATOR AND REINSTALLED CORRECTLY REF W/O 368356 MTC E-35-0025 ITEM 3 TO 5 FOR WORK PERFORMED. OXYGEN BOX/GENERATOR ARE INSTALLED AND POSITIONED CORRECTLY.SDR LR7A2026092503984Bracket · crackedLT MLG INBD DOOR PUSH-PULL ROD BRACKET BROKEN. REMOVED AND REPLACED MLG INNER DOOR ROD END BRACKET LP# 53539SDR AALA202609305420Support Angle · crackedAIRCRAFT IN BASE MAINTENANCE: HORIZONTAL SUPPORT ANGLE CRACKED STA 663 24 INCHES OUTBOARD OF KEEL BEAM L/H SIDE. REMOVED AND REPLACED SUPPORT ANGLE PER SRM 51-20-05 AND EA 379123.SDR CALA2026092920006Relay · faultedSPEED BRAKE DID NOT ARM, LIGHT ON . WHEN TOGA POWER WAS SELECTED FOR TAKEOFF. EXTINGUISHED WITH THRUST IDLE. LIGHT ALSO CAME ON WITH FLAP RETRACTION.AUTO THROTTLE TEST AND SPOILER OPS. TEST PASSED. NO FAULTS SHOWING ON AUTOSPEEDBRAKE CONTROLLER. ACCOMPLISHESDR AALA202609292228Bearing · excess playAIRCRAFT WAS GROUNDED: CAPTAIN'S YOKE HAS ABNORMAL TRAVEL WHEN HAND FLYING. WITH AUTO PILOT OFF, SMOOTH NON TURBULENT AIR, AND NO CONTROL INPUTS, THE YOKE CAN BE ROCKED FORWARD AND BACKWARD, ABOUT THE VERTICAL CONTROL COLUMN. THE BASE OF THE YOKE IS NOT FULLY SDR DALA2026092905418Battery Pack · inoperativeEMERGENCY CEILING LIGHT ABOVE 30ABC INOPERATIVE. REPLACED THE BATTERY PACK AT 29 ABC IAW AMM 33- 31, OPS CHKD GOOD. (9444387) AIRCRAFT WAS GROUNDED.SDR SWAA2026092916162Sign · unsecurePASSENGER CABIN, CEILING EXIT SIGN UNSECURE. SECURED THE SIGN IAW AMM 33-51-01-960-802, STEP 3.C. (6) (E).SDR SWAA2026092992840Knob · missingVOLUME KNOB ON FWARD MEGAPHONE MISSING. REMOVED AND REPLACED FWD GALLEY MEGAPHONE IAW AMM 25-64-00. OPS CHECKED GOOD.SDR SWAA2026092991980Vapor Barrier · crackedFOUND 12 INCH CRACK ON THE VAPOR BARRIER WEB, RBL 40, 40 INCHES DOWN FROM WL. REACCESSED DAMAGE, CRACK FOUND TO BE 18+ INCHES. C/W REPAIR IAW EA 26-157-02619.SDR SWAA2026092925697Seal · crackedRIGHT HORIZONTAL STAB-TO-BODY UPPER FRONT SPAR SLIDING SEAL CRACKED. REMOVED AND REPLACED THE SLIDING SEAL IAW AMM 53-31-31.