AC 43.13-1B

Historical

Advisory circular · Acceptable Methods, Techniques, and Practices—Aircraft Inspection and Repair

A newer version is currentThis is a historical version. AC 43.13-1B CHG 1 Ed Update is the version in force, approved September 27, 2001.
Approved
September 8, 1998
Last reviewed
June 11, 2024
Cancelled by
AC43.13-1B CHG 1
Family
AC 43.13-1 · 7 versions
Revision
B
14 CFR parts
43, 65, 145, 21, 105, 23, 91, 121, 25
Cited by
95 ADs

Guidance, not mandatory unless a rule or AD requires it. DRS record last changed November 21, 2025.

Show pages 586–597
Page 598Open in PDF

9/8/98 AC 43.13-1B

Par 11-122 Page 11-534 used to protect wiring must be equipped with drain holes to prevent entrapment of moisture.

PROTECTION AGAINST PERSONNEL AND CARGO. Wiring must be installed so the structure affords protection against its use as a handhold and damage from cargo. Where the structure does not afford adequate protection, conduit must be used, or a suitable mechanical guard must be provided.

HEAT PRECAUTIONS. Wiring must be routed away from high-temperature equipment and lines to prevent deterioration of insulation.

Wires must be rated (reference paragraph 11-66 and 11-67) so that the conductor temperature remains within the wire specification maximum when the ambient temperature, and heat rise, related to current carrying capacity are taken into account. The residual heating effects caused by exposure to sunlight when aircraft are parked for extended periods should also be taken into account.

Wires such as in fire detection, fire extinguishing, fuel shutoff, and fly-by-wire flight control systems that must operate during and after a fire, must be selected from types that are qualified to provide circuit integrity after exposure to fire for a specified period.

Wire insulation deteriorates rapidly when subjected to high temperatures. Do not use wire with soft polyethylene insulation in areas subject to high temperatures. Use only wires or cables with heat resistance shielding or insulation.

MOVABLE CONTROLS WIRING PRECAUTIONS.

Clamping of wires routed near movable flight controls must be attached with steel hardware and must be spaced so that failure of a single attachment point can not result in interference with controls. The minimum separation between wiring and movable controls must be at least 1/2 inch when the bundle is displaced by light hand pressure in the direction of the controls.

FLAMMABLE FLUIDS AND GASES. An arcing fault between an electrical wire and a metallic flammable fluid line may puncture the line and result in a fire. Every effort must be made to avoid this hazard by physical separation of the wire from lines and equipment containing oxygen, oil, fuel, hydraulic fluid, or alcohol.

Wiring must be routed above these lines and equipment with a minimum separation of 6 inches or more whenever possible. When such an arrangement is not practicable, wiring must be routed so that it does not run parallel to the fluid lines. A minimum of 2 inches must be maintained between wiring and such lines and equipment, except when the wiring is positively clamped to maintain at least 1/2-inch separation, or when it must be connected

Page 599Open in PDF

Par 11-135 Page 11-535 directly to the fluid-carrying equipment. Install clamps as shown in figure 11-10. These clamps should not be used as a means of supporting the wire bundle. A dditional clamps should be installed to support the wire bundle and the clamps fastened to the same structure used to support the fluid line(s) to prevent relative motion.

FIGURE 11-10. Separation of wires from plumbing lines.

11-127.11-134. [RESERVED.]

Page 600Open in PDF

Par 11-135 Page 11-536 SECTION 10. SERVICE LOOP HARNESSES (Plastic Tie Strips)

GENERAL. The primary function of a service loop harness is to provide ease of maintenance. The components, mounted in the instrument panel and on the lower console and other equipment that must be moved to access electrical connectors, are connected to aircraft wiring through service loops. Chafing in service loop harnesses is controlled using the following techniques.

SUPPORT. Only string ties or plastic cable straps in accordance with paragraph 11-158 should be used on service loop harnesses.

A 90° or “Y” type spot tie should be installed at the harness breakout point on the harness bundle. Ties should be installed on service loop harnesses at 4 to 6-inch intervals.

ANTI-CHAFING MATERIAL. When service loops are likely to be in contact with each other, expandable sleeving or equivalent chafe protection jacket material must be installed over service loop harnesses to prevent harness-to-harness chafing. The sleeve should be held in place with string ties at 6 to 8-inch intervals. Harness identification labels should be installed, with string tie, within 3 inches of the service loop harness installation.

STRAIN RELIEF. The strain relief components may be installed to control routing where close clearance exists between termination and other components or bulkheads. Strain relief components provide support of the service loop harness at the termination point.

Connector strain relief adapters, heat-shrinkable boot, or a length of heatshrinkable tubing should be installed. The heat-shrinkable boots will provide preselected angles of wire harness termination when heat is applied. Heat-shrinkable tubing should be held at the desired angle until cool.

“SERVICE LOOP.” Primary support for service loop harness(es) should be a cushion clamp and a connector at the harness termination.

Service loop harnesses should be inspected for the following:

Adequate Length. Components should extend out from their mounting position a distance that permits rotating and unlocking (or locking) the electrical connector. Usually a distance of 3 to 6 inches, with all other components installed, should be sufficient.

Bundle BreakOut Point.

Bundle breakout point should be adequately supported with string tie.

Service loop must maintain a minimum bend radius of 3 times the harness diameter.

The breakout point should be located directly behind, beside, below, or above the component so that the service loop harness does not bind other components.

Plastic ties should not be used between the service loop breakout and the electrical connector when they are likely to chafe against adjacent wire.

Page 601Open in PDF

Par 11-146 Page 11-537 Service Loop Routing. The service loop harness should be routed directly from the breakout point to the component.

The harness should not contact moving mechanical components or linkage, and should not be wrapped or tangled with other service loop harnesses.

Service Loop Harness Termination. Strain relief should be provided at the se rvice loop harness termination, and is normally provided by the connector manufacturer’s backshell, heat-shrinkable boot, or tubing.

11-140.11-145. [RESERVED.]

Page 602Open in PDF

Par 11-146 Page 11-538 SECTION 11. CLAMPING

GENERAL. Wires and wire bundles must be supported by using clamps meeting Specification MS-21919, or plastic cable straps in accessible areas if correctly applied within the restrictions of paragraph 11-158. Clamps and other primary support devices must be constructed of materials that are compatible with their installation and environment, in terms of temperature, fluid resistance, exposure to ultraviolet (UV) light, and wire bundle mechanical loads. They should be spaced at intervals not exceeding 24 inches.

Clamps on wire bundles should be selected so that they have a snug fit without pinching wires, as shown in figure 11-11 through figure 11-13.

CAUTION: The use of metal clamps on coaxial RF cables may cause problems if clamp fit is such that RF cable’s original cross-section is distorted.

Clamps on wire bundles should not allow the bundle to move through the clamp when a slight axial pull is applied. Clamps on RF cables must fit without crushing and must be snug enough to prevent the cable from moving freely through the clamp, but may allow the cable to slide through the clamp when a light axial pull is applied. The cable or wire bundle may be wrapped with one or more turns of electrical tape when required to achieve this fit. Plastic clamps or cable ties must not be used where their failure could result in interference with movable controls, wire bundle contact with movable equipment, or chafing damage to essential or unprotected wiring. They must not be used on vertical runs where inadvertent slack migration could result in chafing or other damage. Clamps must be installed with their attachment hardware positioned above them, wherever practicable, so that they are unlikely to rotate as the result of wire bundle weight or wire bundle chafing. (See figure 11-11.)

Clamps lined with nonmetallic material should be used to support the wire bundle along the run. Tying may be used between clamps, but should not be considered as a substitute for adequate clamping. Adhesive tapes are subject to age deterioration and, therefore, are not acceptable as a clamping means.

The back of the clamp, whenever practical, should be rested against a structural member. Clamps must be installed in such a manner that the electrical wires do not come in contact with other parts of the aircraft when subjected to vibration. Sufficient slack should be left between the last clamp and the electrical equipment to prevent strain at the terminal and to minimize adverse effects on shock-mounted equipment. Where wires or wire bundles pass through bulkheads or other structural members, a grommet or suitable clamp should be provided to prevent abrasion.

When wire bundle is clamped into position, if there is less than 3/8-inch clear ance between the bulkhead cutout and the wire bundle, a suitable grommet should be installed as indicated in figure 11-14. The grommet may be cut at a 45 degree angle to facilitate installation, provided it is cemented in place and the slot is located at the top of the cutout.

WIRE AND CABLE CLAMPS INSPECTION.

Inspect wire and cable clamps for proper tightness. Where cables pass through structure or bulkheads, inspect for proper clamping and grommets. Inspect for sufficient slack between the last clamp and the electronic equipment to prevent strain at the cable terminals and to minimize adverse effects on shock-mounted equipment.

Page 603OCROpen in PDF

DANGEROUS ANGLES

SAFE ANGLES FIGURE 11-11. Safe angle for cable clamps.

MS5-21919

CABLE CLAMP OR

EQUIVALENT MS-27039/NAS 603 SCREW AN 960 - WASHER, AN 960 PLAIN WASHER, PLAIN AN 9368

LOCKWASHER, MS 35338 LOCKWASHER, AN 340 NUT EXTERNAL TEETH SELF-LOCKING MS 21044 NUT, SPLIT FIGURE 11-12. Typical mounting hardware for MS-21919 cable clamps.

Par 11-146 Page 11-539

Page 604Open in PDF

Par 11-147 Page 11-540

FIGURE 11-13. Installing cable clamp to structure.

Page 605OCROpen in PDF

A. CUSHION CLAMP AT MS21919 BULKHEAD HOLE.

CABLE CLAMP

CLEARANCE 3/8" MINIMUM WIRES LESS THAN 3/8 INCH

FROM HOLE EDGE

GROMMET

ANGLE BRACKET WITH

TWO POINT FASTENING MS21919

CABLE CLAMP B. CUSHION CLAMP AT

BULKHEAD HOLE WITH MS35489 GROMMET.

C. CUSHION CLAMP AT

BULKHEAD HOLE WITH MS21266 GROMMET.

ANGLE BRACKET WITH

TWO POINT FASTENING FIGURE 11-14. Clamping at a bulkhead hole.

11-148.11-154. [RESERVED.] Par 11-155 Page 11-541

Page 606Open in PDF

Par 11-155 Page 11-542 SECTION 12. WIRE INSULATION AND LACING STRING TIE

GENERAL. Insulation of wires should be appropriately chosen in accordance with the environmental characteristics of wire routing areas. Routing of wires with dissimilar insulation, within the same bundle, is not recommended, particularly when relative motion and abrasion between wires having dissimilar insulation can occur. Soft insulating tubing (spaghetti) cannot be considered as mechanical protection against external abrasion of wire; since at best, it provides only a delaying action. Conduit or ducting should be used when mechanical protection is needed.

INSULATION MATERIALS. Insulating materials should be selected for the best combination of characteristics in the following categories:

Abrasion resistance.

Arc resistance (noncarbon tracking).

Corrosion resistance.

Cut-through strength.

Dielectric strength.

Flame resistance.

Heat distortion temperature.

Impact strength.

Mechanical strength.

Resistance to fluids.

Resistance to notch propagation.

Smoke emission.

Special properties unique to the aircraft.

For a more complete selection of insulated wires refer to SAE AS 4372 Aerospace Wire Performance Requirement and SAE AS 4373 Test Methods for Aerospace Wire.

STRIPPING INSULATION.

Attachment of wire, to connectors or terminals, requires the removal of insulation to expose the conductors.

This practice is commonly known as stripping.

Stripping may be accomplished in many ways; however, the following basic principles should be practiced.

Make sure all cutting tools used for stripping are sharp.

When using special wire stripping tools, adjust the tool to avoid nicking, cutting, or otherwise damaging the strands.

Damage to wires should not exceed the limits specified in table 11-13.

When performing the stripping operation, remove no more insulation than is necessary.

LACING AND TIES. Ties, lacing, and straps are used to secure wire groups or bundles to provide ease of maintenance, inspection, and installation. Braided lacing tape per MIL-T-43435 is suitable for lacing and tying wires. In lieu of applying ties, straps meeting Specification MS17821 or MS17822 may be used in areas where the temperature does not exceed 120 ºC. Straps may not be used in areas of SWAMP such as wheel wells, near wing flaps or wing folds. They may not be used in high vibration areas, where failure

Page 607Open in PDF

Par 11-155 Page 11-543 TABLE 11-13. Allowable nicked or broken strands.

Maximum allowable nicked and broken strands Wire Size Conductor material Number of strands per conductor Total allowable nicked and broken strands 24-14 12-10 8-4 2-1 0-00 000 0000

8-000 Copper or Copper Alloy

Aluminum 19 37 133 665-817 1,045-1,330 1,665- 2,109-

All numbers of strands

2 nicked, none broken 4 nicked, none broken 6 nicked, 6 broken 6 nicked, 6 broken 6 nicked, 6 broken 6 nicked, 6 broken 6 nicked, 6 broken

None, None

of the strap would permit wiring to move against parts which could damage the insulation and foul mechanical linkages or other moving mechanical parts. They also may not be used where they could be exposed to UV light, unless the straps are resistant to such exposure.

Lacing. Lace wire groups or bundles inside junction boxes or other enclosures. Single cord-lacing method, shown in figure 11-15, and tying tape, meeting specification MIL-T-43435, may be used for wire groups of bundles 1-inch in diameter or less. The recommended knot for starting the single cord-lacing method is a clove hitch secured by a double-looped overhand knot as shown in figure 11-15, step a. Use the double cord-lacing method on wire bundles 1-inch in diameter or larger as shown in figure 11-16. When using the double cord-lacing method, employ a bowline on a bight as the starting knot.

Tying. Use wire group or bundle ties where the supports for the wire are more than 12 inches apart. A tie consists of a clove hitch, around the wire group or bundle, secured by a square knot as shown in figure 11-17.

Plastic Ties. Refer to Paragraph 11-220 and table 11-

21.

INSULATION TAPE. Insulation tape should be of a type suitable for the application, or as specified for that particular use. Insulation tape should be used primarily as a filler under clamps and as secondary support.

Nonadhesive tape may be used to wrap around wiring for additional protection, such as in wheel wells. All tape should have the ends tied or otherwise suitably secured to prevent unwinding. Tape used for protection should be applied so that overlapping layers shed liquids.

Drainage holes should be provided at all trap points and at each low point between clamps.

Plastic tapes, that absorb moisture or have volatile plasticizers that produce chemical reactions with other wiring, should not be used. (Reference MIL-W-5088.)

Page 608OCROpen in PDF

PULL HERE UNTIL TIGHT

BEFORE FINISHING KNOT

CORD CROSSES

UNDER LOOP STEP a - STARTING KNOT

STARTING FINAL KNOT KNOT _

TIGHTENED STEP b - INTERMEDIATE HALF HITCHES FIRST PART OF FINAL STEP c - (PART I) KNOT TIGHTENED TRIM TO 3/8" MIN. STEP c - (PART II) FINAL KNOT FIGURE 11-15. Single cord lacing.

STEP a STARTING KNOT -

BOWLINE ON A BIGHT

STARTING KNOT TIGHTENED STEP b INTERMEDIATE HALF HITCHES STEP c FINAL KNOT FIGURE 11-16. Double cord lacing.

Par 11-167 Page 11-544 (and 11-66)

Page 609Open in PDF

Par 11-167 Page 11-545 (and 11-66)

FIGURE 11-17. Making ties.

11-160.11-166. [RESERVED.]