Par 11-272 Page 11-588 TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Transmission Patch Conductor Cable Wiring

Distribution Lines Transmission Lines

Alternative or Conditioned Wiring

Associated or Future

Page 653Open in PDF

Par 11-272 Page 11-589 TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Intentional Isolation of Direct-Current Path in Coaxial or Waveguide Applications

Waveguide

Strip-Type Transmission Line

Termination

Circuit Return

Pressure-Tight Bulkhead Cable Gland Cable Sealing End

Switching Function

Electrical Contact

Page 654Open in PDF

Par 11-272 Page 11-590 TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Basic Contact Assemblies

Magnetic Blowout Coil

Operating Coil Relay Coil

Switch

Pushbutton, Momentary, or Spring-Return

Page 655Open in PDF

Par 11-272 Page 11-591 TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Two-Circuit, Maintained, or Not Spring-Return

Nonlocking Switching, Momentary, or Spring- Return

Locking Switch

Combination Locking and Nonlocking Switch

Key-Type Switch Lever Switch

Page 656Open in PDF

Par 11-272 Page 11-592 TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Selector or Multiposition Switch

Safety Interlock

Limit Switch Sensitive Switch

Switches with Time-Delay Feature

Flow-Actuated Switch

Page 657Open in PDF

Par 11-272 Page 11-593 TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Liquid-Level Actuated Switch

Pressure- or Vacuum-Actuated Switch

Temperature-Actuated Switch

Thermostat

Flasher Self-Interrupting Switch

Foot-Operated Switch Foot Switch

Switch Operated by Shaft Rotation and Responsive to Speed or Direction

Switches with Specific Features

Page 658Open in PDF

Par 11-272 Page 11-594 TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Governor Speed Regulator

Relay

Inertia Switch

Mercur Switch

Terminals

Page 659Open in PDF

Par 11-272 Page 11-595 TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Cable Termination

Connector Disconnecting Device

Connectors of the Type Commonly Used for Power-Supply Purposes

Test Blocks

Coaxial Connector

Waveguide Flanges Waveguide Junction

Page 660Open in PDF

Par 11-272 Page 11-596 TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Fuse

Lightning Arrester Arrester Gap

Circuit Breaker

Protective Relay

Audible-Signaling Device

Microphone

Page 661Open in PDF

Par 11-272 Page 11-597 TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Handset Operator’s Set

Lamp

Visual-Signaling Device

Mechanical Connection Mechanical Interlock

Mechanical Motion

Clutch Brake

Page 662Open in PDF

Par 12-1 Page 12-598 (and 12-2) TABLE 11-27. Electronic/Electrical Symbols (continued).

Symbol Meaning

Manual Control

Gyro Gyroscope Gyrocompass

Position Indicator

Fire Extinguisher Actuator Head

Position Transmitter

Radio Station

Space Station

Page 663OCROpen in PDF

Integrated Circuit Amplifiers

GENERAL SYMBOLS MAGNETIC AMPLIFIER

INVERTOR OR

NOT GATE Logic Gates

AND GATE WITH THREE INPUTS NAND (NOT AND) GATE

OR GATE NOR (NOT OR) GATE

EXCLUSIVE OR GATE Diode

EMITTER BASE COLLECTOR Transistor Symbols

EMITTER BASE COLLECTOR E- - C E B

11-273.11-283. [RESERVED.] Par 12-1 Page 12-599 (and 12-2)