N1409A
Service difficulty reports · 458
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1409A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1409A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2018052210924Warning Message · false activationRIGHT FORWARD WINDOW HEAT WARNING AFTER LANDING. COMPLIED WITH FIM 30-41, WINDOW ANTI ICE BITE PROCEDURE. FOUND NO DEFECTS AT THIS TIME.SDR UIEA201805220922Heater · malfunctionedRIGHT FWD WINDSHIELD HEAT CYCLED OFF BEFORE TAKEOFF AND AFTER LANDING. PERFORMED A WINDOW HEAT OPS CHECK IAW AMM 30-41-00 FOR 15 MINUTES , NO DEFECTS NOTED.SDR UIEA2018052280913Generator · malfunctionedDESENDING THROUGH 18000 FEET, LOST RIGHT GENERATOR, RAN QRH FOR RT AC BUSS OFF, RESET GEN & ISOLATION BUSS TIE, NO ANOMOLIES AFTER RESET. SERVICED THE RT IDG IAW AMM 12-13-03 , PERFORMED BPCU BITE PROCEDURE, NO FAULTS NOTED IAW FIM 24-20 FT 801 IAW MX OPERASDR UIEA2018051800912Warning Message · false activationWHILE APU WAS STARTING, THE RT FED WINDOW HEAT CAUTION MESSAGE APPEARED. COMPLIED WITH FIM 30-41 FAULT TREE 804, NO FAULTS FOUND, OPS NORMAL.SDR UIEA2018051200886Fire Warning · false activationMAIN DECK CARGO FIRE LIGHT REPEATEDLY COMES ON DURING PREFLIGHT. PERFORMED BITE PROCEDURE FOR THE CARGO COMPARTMENT SMOKE DETECTION SYSTEM, NO FAULTS NOTED, NO WARNING MESSAGES NOTED AS PER FIM 26-14 FT 809.SDR UIEA2018051200885Warning System · false activationRIGHT FDW WINDOW EICAS MSG. OPS CHECK GOOD IAW AMM 30-41-00, NO DEFECTS AT THIS TIME.SDR UIEA2018042700805Warning Message · false activationRIGHT FORWARD WINDOW HEAT INOPERATIVE 25 SECONDS AFTER TOUCHDOWN. PERFORMED AN OPS CHECK OF THE R1 WINDOW HEAT IAW AMM 30-41-00, NO FAULTS FOUND.SDR UIEA2018050100797Warning Message · false activationRIGHT FWD WINDOW HEAT INOPERATIVE. PERFORMED FIM 30-41 FT 804, NO FAULTS FOUND , ACFT OK FOR SERVICE.SDR UIEA2018042700811Pump · unknownLEFT AFT BOOST PUMP INOPERATIVE. TROUBLESHOT IAW FIM 28-22 TREE 819. CHECKED WIRING IAW FIM 28-22- TREE 819, NO FAULTS FOUND.SDR UIEA2018042300765Control Panel · malfunctionedON TOUCHDOWN, THE RT WINDOW HEAT EICAS MESSAGE ILLUMINATED. RAN QRH AND EICAS MESSAGE CLEARED. TROUBLESHOT & FOUND BROKEN INSULATION AT TR324. REPAIRED THE INSULATION IAW SWPM 20-10-13. R & R THE WINDOW ANTI ICE CONTROL PANEL IAW AMM 30-41-00, OPS CHECKS GOSDR UIEA2018042400778Control Valve · faultedLEFT PACK TEMP ILLUMINATED ON SHORT FINAL AND AGAIN DURING TAXI IN. TROUBLESHOT THE LEFT PACK TEMP MESSAGE IAW FIM 21-51 FT 848, FOUND PACK TEMP CONTROL VALVE TO BE AT FAULT, REMOVED AND REPLACED THE PACK TEMP CONTROL VALVE IAW AMM 21-51-12. INSTALLATION TESDR UIEA201804240756Window · inoperativeRIGHT FWD WINDOW HEAT INOPERATIVE DURING TAXI. R & R THE WINDOW IAW AMM 56-11-01. OPS CHECKED NORMAL.SDR UIEA201804230755Warning Message · false activationRIGHT FWD WINDOW HEAT CAUTION MESSAGE DURING LANDING. PERFORMED AN OPS CHECK OF THE RIGHT FWD WINDOW HEAT. OPS CHECKED GOOD , NO FAULTS NOTED IAW AMM 30-41-00.SDR UIEA2018041900738Warning Message · false activationRIGHT FWD WINDOW MESSAGE. PERFORMED A WINDOW HEAT OPS CHECK IAW AMM 30-41-00, OPS CHECKED GOOD.SDR UIEA2018042080735Warning Message · false activationRIGHT WINDOW HEAT CAUTION MESSAGE AFTER LANDING. TROUBLESHOT IAW FIM 30-41 FT 804, DISCONNECTED THE WIRES FROM THE WHCU TO MAIN SENSOR AND CONNECTED TO THE SPARE SENSOR , PERFORMED WINDOW ANTI-ICING SYSTEM OPS CHECK IAW AMM 30-41-00, OPS CHECKED GOOD.SDR UIEA2018041800724Sensor · looseRIGHT FWD WINDOW HEAT EICAS MESSAGE. TROUBLESHOT IAW W/D 30-41-12, AND FIM 30-41 F/T 802 . CONNECTOR D2898B, PINS 1 AND 2 115 VAC. VERIFY INTEGRITY S1 SWITCH AT PIN 6 D2898A. RESISTANCE CHECK OF WINDOW WITHIN LIMITS. INSPECTED WINDOW SENSOR 1 AND FOUND LOOSDR UIEA2018041700721Warning Message · false activationRIGHT FWD WINDOW EICAS MESSAGE. WINDOW ANTI-ICE SYSTEM OPS CHECKED IAW AMM 30-41-00. NO FAULS NOTED. OPS CHECKED OK.SDR UIEA2018041800732Control Unit · malfunctionedEICAS MESSAGE AFTER LANDING, FOR THE RT FWD WINDOW. REMOVED AND REPLACED THE RIGHT FWD WINDOW HEAT CONTROL UNIT. OPS CHECKED GOOD IAW 30-41-01.SDR UIEA2018041500702Control Unit · malfunctionedAFTER LANDING, AN EICAS MESSAGE FOR THE RT FWD WINDOW. REMOVED AND REPLACED THE WINDOW HEAT CONTROL UNIT IAW AMM 30-41-01-004-001, AND 30-41-01-404-007. OPS CHECKED GOOD, NO FAULTS NOTED.SDR UIEA2018041400701Warning Message · false activationRIGHT FWD WINDOW HEAT ADVISORY MESSAGE, AFTER LANDING. PERFORMED A SYSTEM CHECK OF THE RT FWD WINDOW HEAT IAW AMM 30-41-00. NO DEFECT NOTED.SDR UIEA2018041600711Gcu · failedRIGHT AC BUSS FAILED DURING DESCENT, QRH PROCEDURE RESTORED POWER WITH RT ISL ILLUMINATED. PERFORMED BITE CHECK ON THE BPCU, FOUND DP TRIPPED, MAIN BUSS, OVERLAP ZONE MESSAGE , REMOVED AND REPLACED THE RIGHT GCU, OPS CHECKED GOOD IAW AMM 24-22-02.SDR UIEA2018041200693Idg · inoperativeRIGHT IDG INOPERATIVE. REMOVED AND REPLACED THE RT IDG IAW AMM 24-11-01, OPS CHECKED GOOD.SDR UIEA2018041200692Gcu · malfunctionedR AC BUS FAILURE IN DESCENT, QRH PROC RESTORED PWR W/R ISL ILLUMINATED. PERFORMED BIT CHECK ON BPCU, FOUND DP TRIP/MAIN BUS/OVERLAP ZONE MESSAGE. REMOVED AND REPLACED RT GCU, OPERATIONAL CHECK GOOD IAW AMM 24-22-02.SDR UIEA2018040900643Buss · malfunctionedRIGHT AC BUSS OFF EICAS MESSAGE DURING DECENT, QRH COMPLIED WITH. FIM 24-20 F/T 801. OBSERVED FAULT, IDG HIGH RISE TEMP COMPLETED, IDG SERVICING ON RT IAW MCC REQUEST IAW AMM 12-13-03. NO CURRENT BUSS ISSUES NOTED.SDR UIEA2018040900642Gcu · malfunctionedDURING DESCENT, WHEN TURNING LANDING LIGHTS ON, THE RT AC BUSS OFF EICAS ILLUMINATED. RT GENERATOR CONTROL, RT BUSS TIE, QRH COMLETED. RESET THE RT GENERATOR CONTROL AND RT BUSS TIE PREVIOUS FLT HAD SAME RESULT. ISOLATION AND BOTH UTILITY BUSS SHED. REMOVESDR UIEA2018041000655Controller · malfunctionedRT FWD WINDOW HEAT EICAS MESSAGE ON LANDING. RERACKED THE WINDOW HEAT CONTROLLER AND PERFORMED TEST. OPS CHECKED GOOD IAW AMM 30-41-00.SDR UIEA2018040800632Heater · faultedRIGHT FWD WINDOW HEAT FAULTED. PERFORMED AN OPS CHECK OF THE RT FWD WINDOW HEAT. OPS CHECKED GOOD IAW AMM 30-41-00.SDR UIEA2018040700627Controller · malfunctionedCABIN ALT AUTO 2 STATUS MESSAGE. PERFORMED A BITE TEST OF PRESSURE CONTROLLER , NO FAULTS FOUND, RESET THE UNIT IAW FIM 21-31 FT 803.SDR UIEA2018040700628Transformer · malfunctionedTR UNIT STATUS MESSAGE. PERFORMED A BITE TEST ON THE TR UNIT, NO FAULTS FOUND , RESET UNIT, SYSTEM OK IAW FIM 24-32 FT 803.SDR UIEA2018040700625Bpcu · failedRIGHT AC BUSS FAIL INDICATED , RECYCLING RT GENERATOR RESTORED POWER TO RIGHT AC BUSS , RESSETING RT BUSS ISOLATION SWITCH UNSUCCESFUL , OCCURED DESCENDING THROUGH 18000 FT. PERFORMED AN OPS CHECK OF BPCU, OPS CHECK FAILED, REMOVED AND REPLACED BPCU IAW AMM 2SDR UIEA2018031700421Warning System · false activationON APPROACH RT FWD WINDOW HEAT FAILED. OPS CHECKED RT FWD WINDOW HEAT NO FAULT FOUND IAW AMM 30-40-00.SDR UIEA2018030800351Hmu · malfunctionedRIGHT ENGINE APPROACH IDLE INOPERATIVE. ONCE RIGHT ENGINE STARTED, ENGINE WENT TO APPROACH IDLE RANGE OF 44% N1 AND 77% N2, REMOVED & REPLACED THE RT ENGINE EEC IAW AMM 73-21-15. OPS CHECKED NORMAL. REMOVED & REPLACED THE RT HMU IAW AMM 73-21-14, OPS CHECSDR UIEA2018030900355Connector · dirtyRIGHT FWD WINDOW HEAT INOPERATIVE. PERFORMED WINDOW HEAT GROUND TEST IAW AMM 30-41-00, NO DEFECTS NOTED, CLEANED & SECURED THE CONNECTOR ON THE WINDOW HEAT CONTROL PANEL ( P5 ) IAW SWPM 20-60-01, CHECKED CONTINUITY FROM PIN 9 TO PIN 8 ON CONTROLLER, NO DEFESDR UIEA2018031200369Eec · malfunctionedONCE THE RIGHT ENG STARTED, THE ENGINE WENT TO APPROACH IDLE RANGE OF 44% N1 & 77% N2. REMOVED & REPLACED THE RIGHT ENGINE EEC IAW AMM 73-21-15, OPS CHECKED NORMAL.SDR UIEA2018030700347Idg · failedRIGHT GENERATOR FAILED ON ARRIVAL WITH RIGHT AC BUSS FAILURE WHEN LOGO LIGHTS SELECTED ON. REPLACED THE RIGHT IDG IAW AMM 24-11-01, NO FAILURES NOTED. FUNCTIONAL CHECKED IAW AMM 74-11-00-75. FUNCTIONAL CHECKED GOOD IAW AMM 24-11-00-75.SDR UIEA2018030500323Heater · malfunctionedRT FORWARD WINDOW HEAT INOPERATIVE, TROUBLESHOT THE RIGHT FORWARD WINDOW HEAT IAW FIM 30-41-01, FAULT TREE 802 AND 804. CHECKED WITHIN LIMITS.SDR UIEA2018030400321Warning Message · false activationFWD EQ EXHAUST FAN STATUS MESSAGE. PERFORMED AN OPS CHECK ON THE FWD EQ FAN IAW AMM 21-25-01. OPS CHECKED GOOD. MESSAGE CLEARED.SDR UIEA2018030400320Control Unit · failedRIGHT GENERATOR TRIPPED IN FLIGHT, RESET THE GEN CIRCUIT BRAKER & RT BUS TIE CIRCUIT BREAKER. REMOVED AND REPLACED THE RT GENERATOR CONTROL UNIT IAW AMM 24-22-02. OPS CHECKED GOOD. NO DEFECTS NOTED.SDR UIEA2018030600339Warning Message · false activationAFTER LANDING, HAD A RT FWD WINDOW EICAS MESSAGE. REPLACED THE WINDOW HEAT CONTROLLER, TESTED NORMAL IAW MM 30-41-07.SDR UIEA2018030200314Lead · dirtyFO FWD SIDE WINDOW EICAS MESSAGE. INOPERATIVE LIGHT REMAINED ILLUMINATED. CLEANED WINDOW LEADS, OPS CHECKED WINDOW HEAT FOR 1/2 HOUR, NO FAULTS NOTED, OPS NORMAL IAW SWPM 20-10-04 & AMM 30-41-00.SDR UIEA2018030200309Anti-Ice System · malfunctionedDURING CRUISE, AT FL 380, IN CLEAR WEATHER. BOTH ENGINE ANTI-ICE CAME ON WITH SELECTOR IN AUTO. TURNED THE ANTI-ICE OFF AND ICING ENGINE EICAS MESSAGE CAME ON. NORMAL OPERATION IAW FIM 30-90-20-00. PERFORMED OPS CHECK IAW AMM 30-81-01, NO DEFECTS NOTED, OSDR UIEA2018030200313Apu · faultedAPU FAULTED ON FIRST START ATTEMPT. OPS CHECKED GOOD IAW FIM 49-11, TASK 958.SDR UIEA2018021900253Ecu · failedAPU NOT SUPPLYING AIR PRESSURE. REMOVED AND REPLACED APU ECU IAW 49-61-05, OPS CHECKED GOOD.SDR UIEA2018020500181Connector · dirtyLT ENGINE ANTI ICE EICAS ILLUMINATED DURING ENGINE RUN. REMOVED AND CLEANED THE ANTI ICE CONNECTOR, CHECKED PINS J1,J2 & J3 IAW FIM 30-21 TR 803, RAN ENGINE OPS CHECKED GOOD.SDR UIEA2018012900151Warning Message · false activationDURING APPROACH WITH APU RUNNING, AT 1000 AGL, AN EICAS APU GENERATOR OFF AND THEN AN APU FAULT DISPLAYED. PERFORMED A BITE CHECK ON ECU, NO DEFECTS NOTED. UNABLE TO DUPLICATE ISSUES. PERFORMED OPS CHECK IAW AMM 49-01-00.SDR UIEA2018012500111Pump · inoperativeLEFT WING AFT FUEL PUMP INOPERATIVE. TROUBLESHOT IAW FIM 28-22- FT 820, WIRING CHECKED GOOD. REMOVED AND REPLACED THE BOOST PUMP, OPS CHECKED GOOD IAW AMM 28-22-03. NO LEAKS NOTED.SDR UIEA2018012300104Circuit Breaker · trippedFOUND THE LT AFT FUEL PUMP CIRCUIT BREAKER TRIPPED. PERFORMED CIRCUIT BREAKER RESET AND PERFORMED OPS CHECK IAW AMM 28-22-00, OPS CHECKED GOOD.SDR UIEA2018011100056Apu · shutdownAPU AUTO SHUTDOWN, WILL NOT RESTART. REMOVED AND REPLACED THE APU IAW AMM 49-11-01 OPS AND LEAK CHECKED.SDR UIEA2018010800032Switch · brokenWEATHER RADAR PANEL HAS A BROKEN SWITCH. REPLACED WEATHER RADAR PANEL IAW AMM 34-43-02. OPS CHECKED GOOD.SDR UIEA2018010300010Transceiver · failedWITH TILT IN AUTO, RIGHT WEATHER RADAR SHOWS 16 DOWN MANUAL TILT (-16M). REMOVED AND REPLACED RT WEATHER RADAR TRANSCEIVER IAW AMM 34-43-01, OPS CHECKED GOOD.