N211WN
Service difficulty reports · 300
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N211WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N211WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022122073518Strap · corrodedAFT CABIN FLOOR STRAP BS 1016+7 - 1016+14, RBL 3, WL 208.1 WAS CORRODED. REMOVED AND REPLACED THE STRAP IAW SRM 51-40-02-0G-0.SDR SWAA2022122073525Floorbeam · corrodedAFT CABIN FLOOR BEAM STA 986.5, LBL 43, WL 208.1 WAS CORRODED. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-02-0G-0.SDR SWAA2022122073516Floorbeam · corrodedAFT CABIN FLOOR BEAM STA 986.5 RBL 28 TO RBL 45 WL 208.1 HAS CORROSION. AFT CABIN FLOORBEAM STA. 986.5; RBL 28 TO RBL 45; WL 208.1 WAS FOUND WITH EXFOLIATION CORROSION; OUT OF LIMITS PER REFERENCE SRM 53-70-51-1A-1. ACCOMPLISHED FLOOR BEAM STA986.5 REPAIR RESDR SWAA2022122073514Structure · corrodedAFT CABIN RT SIDE INNER CHORD BETWEEN STA 951 AND STA 992.8 RBL 46 TO RBL 55 WL 208.1 WAS CORRODED. OUT OF LIMITS IAW SRM 53-70-15-1A-1. REMOVED CORRODED R2 DOOR CHORD IAW SRM 51-40-02-0G-0. LOCATED AND DRILL A NEW CHORD IAW 51-40-05-0G-0. TREATED AND PRISDR SWAA2022122073880Floor Support · crackedFLOOR SUPPORT BL-0 BS 540 CRACKED. REMOVED THE FLOOR SUPPORT IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED A NEW FLOOR SUPPORT IAW SRM 51-40-05-0G-0 AND INSTALLED IAW SRM 51-40-02-0G-0.SDR SWAA2022121973885Gusset · crackedGUSSET CRACKED, STRINGER 19R, BS 500D. REMOVED THE GUSSET IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED A NEW GUSSET IAW SRM 51-40-05-0G-0. TREATED AND PRIMED THE NEW GUSSET AND FASTENER HOLES IAW SRM 51-20-01-0G-0. INSTALLED THE NEW GUSSET IAW SRM 51-40-SDR SWAA2022122073498Floor Support · crackedFWD CABIN BETWEEN BS 344 - 360, BL 0, WL 208.1 INTERCOSTAL WAS CRACKED. REMOVED AND REPLACED THE INTERCOSTAL IAW SRM 51-40-02-0G-0, 51-40-05-0G-0, 51-20-01-0G-0, AND DWG 141A5400.SDR SWAA2022122073511Floor Support · crackedFWD CABIN INTERCOSTAL, BS 344 - 360, RBL 11, WL 208.1 CRACKED. REMOVED AND REPLACED THE INTERCOSTAL AND BRACKET IAW SRM 51-40-02-0G-0, 51-40-05-0G-0, 51-20-01-0G-0, AND DWG 141A5410.SDR SWAA2022122073502Floor Support · corrodedFWD CABIN INTERCOSTAL BETWEEN BS 294.5 - 312, LBL 11, WL 208.1 WAS CORROED. REMOVED AND REPLACED THE INTERCOSTAL IAW SRM 51-10-02-0G-0 AND DWG 141A5600.SDR SWAA2022122073500Tie Down · corrodedFWD CABIN, BS 312, LBL 55, WL 208.1 FLOOR FITTING WAS CORRODED. REMOVED AND REPLACED THE FLOOR TIEDOWN FITTING IAW 51-10-15-1A-1 AND 51-40-02-0G-0.SDR SWAA2022122073184Floor Panel · corrodedAFT CABIN FLOOR PANEL 241ACF HAD CORRODED INSERTS. NEW FLOOR PANEL INSTALLED ON TTG8Q00F6J7Q.SDR SWAA2022121973499Intercostal · crackedFWD CABIN BS 312 - 328, RBL 32, WL 208.1 INTERCOSTAL WAS CRACKED. REMOVED THE INTERCOSTAL IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED A NEW INTERCOSTAL IAW 51-40-05 -0G-0. APPLIED PRIMER IAW 51-20-01-0G-0. INSTALLED THE NEW INTERCOSTAL IAW SRM 51-40-02-0GSDR SWAA2022121973513Intercostal · crackedFWD CABIN BETWEEN BS 380 - 400, RBL 41, WL 208.1 INTERCOSTAL WAS CRACKED. INSTALLED EWIS PROTECTION IAW AMM 20-60-07-913-801. REMOVED THE INTERCOSTAL IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED THE INTERCOSTAL IAW SRM 51-40-05-0G-0. APPLIED PRIMER IAW SRMSDR SWAA2022121973510Intercostal · crackedFWD CABIN BETWEEN BS 328 & 344, LBL 45, WL 208.1, INTERCOSTAL WAS CRACKED. REMOVED THE INTERCOSTAL IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED A NEW INTERCOSTAL IAW SRM 51-40-05-0G-0. TREATED AND PRIMED IAW SRM 51-20-01-0G-0. INSTALLED THE NEW INTERCOSTALSDR SWAA2022121973181Floor Panel · damagedAFT CABIN FLOOR PANEL 241UF UPPER SKIN SURFACE PEELING. RECEIVED A NEW FLOOR PANEL 241UF. TASK CARD WILL BE ACCOMPLISH ON TTG8Q00FEM3M.SDR SWAA2022121973182Floor Panel · damagedAFT CABIN FLOOR PANEL 242QF UPPER SKIN SURFACE HAS MATERIAL MISSING. RECEIVED NEW FLOOR PANEL 242QF NEW FLOOR PANEL TO BE INSTALLED ON TTG8Q00FEM3Q.SDR SWAA2022121973185Floor Panel · delaminatedAFT CABIN FLOOR PANEL 241AEF DELAMINATED. RECEIVED NEW CABIN FLOOR PANEL 241AEF. NEW FLOOR PANEL TO BE INSTALLED ON TTG8Q00F6J7L.SDR SWAA2022121973186Floor Panel · damagedAFT CABIN FLOOR PANEL 242PF UPPER SKIN SURFACE HAS MATERIAL MISSING. RECEIVED NEW FLOOR PANEL 242PF. TASK CARD WILL BE ACCOMPLISH ON TTG8Q00FEM3S.SDR SWAA2022121973187Floor Panel · brokenAFT CABIN FLOOR PANEL 241ADF BROKEN. RECEIVED NEW AFT CABIN FLOOR PANEL 241ADF. TASK CARD WILL BE ACCOMPLISHED ON BARCODE TTG8Q00F6J7N.SDR SWAA2022121973188Floor Panel · damagedAFT CABIN FLOOR PANEL 241ZF UPPER SKIN SURFACE PEELING. RECEIVED NEW CABIN FLOOR PANEL 241ZF. NEW FLOOR TO BE INSTALLED ON BAR CODE TTG8Q00F6J7W.SDR SWAA2022121973189Floor Panel · damagedAFT CABIN FLOOR PANEL 241YF UPPER SKIN SURFACE PEELING. RECEIVED NEW CABIN FLOOR PANEL 241YF. NEW FLOOR PANEL TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q00F6J88.SDR SWAA2022121973190Floor Panel · brokenAFT CABIN FLOOR PANEL 241ABF BROKEN. (18-075)<[01] RECEIVED NEW CABIN FLOOR PANEL 241 ABF. NEW FLOOR TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q00G63CU.SDR SWAA2022121973192Floor Panel · brokenAFT CABIN FLOOR PANEL 242UF BROKEN. (18-073)<[01] RECEIVED NEW CABIN FLOOR PANEL 242UF. NEW FLOOR PANEL TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q00F6JFT;[02] VERIFIED STEP 1.SDR SWAA2022121973193Floor Panel · delaminatedAFT CABIN FLOOR PANEL 242WF DELAMINATED. RECEIVED NEW CABIN FLOOR PANEL 242 WF. NEW FLOOR TO BE INSTALLED ON BAR CODE TTG8Q00F6JFP.SDR SWAA2022121973512Floor Support · crackedFWD CABIN BETWEEN STA 380 AND STA 400 LBL 13 WL 208.1 INTERCOSTAL IS CRACKED. 124-054<[01] REMOVED AND REPLACED INTERCOSTAL AT FWD CABIN BETWEEN STA 380 AND STA 400 LBL 13 WL 208.1 IN REF SRM 51-40-02-0G-0;[02] INSTALLED NEW INTERCOSTAL AT FWD CABIN BETWEEN STSDR SWAA2022122073074Door Frame · crackedFWD ENTRY DOOR FRAME BS312, S5L, WL 297 WAS CRACKED. ACCOMPLISHED EA M-22-153-01244; FOR TRIMOUT ON FWD ENTRY DOOR FRAME.SDR SWAA2022122072707Rib · crackedR/H HORIZONTAL STAB INTERNAL SURFACE RIB 5 HSS 129.50 STIFFENER 2 CRACKED. CUT AND REMOVED DAMAGE FROM THE VERTICAL STIFFENER PER REF. SRM 55-10-09-2R-4. LOCATED AND DRILLED REPAIR PARTS AND RIB PER REF SRM 51-40-05-0G-0, INSTALLED REPAIR PARTS WITH BMS 5-SDR SWAA2022122071812Door · corrodedLEFT AFT TOILET SERVICE DOOR 145AL INTERNAL SKIN SURFACE WAS CORRODED. PERFORMED SRM 51-10-02-0G-0, NDT PART 4, 51-00-00, PROC 3. FOUND OUT OF LIMITS IAW SRM 52-40-01-1A-4, FIG 103. REPAIRED IAW SRM 51-40-02-0G-0, SWPM 20-20-00, AND DRAWING 146A7410.SDR SWAA2022122072704Strip · elongatedAFT CARGO R/H; FWD CAP STRIPS WITH HOLES ELONGATED. RECEIVED NEW AFT CARGO R/H CAP STRIPS. NEW CAP STRIPS INSTALLED ON TTG8Q004DYH6.SDR SWAA2022122072705Strip · damagedAFT CARGO; L/H CAP STRIPS WITH HOLE ELONGATE. RECEIVED NEW AFT CARGO L/H CAP STRIPS 453A2611-13; -9; AND-11. NEW CAP STRIPS INSTALLED ON TTG8Q004DYH6.SDR SWAA2022122071792Retainer · crackedLT WING FIXED T/E SUPPORT APPROX WING RIB 7 JUST I/B OF DEFLECTION CONTROL RIB - 2EA SEAL RETAINERS ARE CRACKED<[01] REMOVED LT WING T/E DEFLECTION CONTROL RIB SEAL RETAINER; REF. SRM 51-40-02-0G-0;[02] VERIFIED STEP 1;[03] OK TO INSTALL SEAL AND RETAINER;[04]SDR SWAA2022092216205None · missingRIGHT OVERWING EXIT AFT LOWER EXIT SIGN LENS MISSING. / [01] INSTALLED LENS COVER; REF AMM 33-51-04. NO FURTHER DEFECTS NOTED.SDR SWAA2022072028070Lens · looseL-1 DOOR EXIT LIGHT LENS IS LOOSE. / [01] REPLACED AND INSTALLED EXIT LIGHT LENS ON L-1 DOOR IAW AMM 33-51-01-960-802 STEP 3. (5); (D); (10)<BR><BR> A-TAG: A136520 P/N: 702409DME1008;[02] ALL WORK C/W<BR>AUDIT C/WSDR SWAA2022072227915Floor Panel · pulledCABIN FLOOR PANEL 242AF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED FLOOR PANEL 242AF FOUND WITHIN REPAIRABLE LIMITS OF SRM 53-00-50-2R-1 REPAIR 1;[02] PREPPED FLOOR PANEL 242AF FOR WET LAY-UP REPAIR IAW B737-700 SRM 53-00-50-2R-1 REPAIR 1 STEPS 3 (A-K);[SDR SWAA2022072227921Floor Panel · pulledCABIN FLOOR PANEL 231ZF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED FLOOR PANEL 231ZF FOUND WITHIN REPAIRABLE LIMITS OF SRM 53-00-50-2R-1 REPAIR 1;[02] PREPPED FLOOR PANEL 231ZF FOR WET LAY-UP REPAIR IAW B737-700 SRM 53-00-50-2R-1 REPAIR 1 STEPS 3 (A-K);[SDR SWAA2022072227920Floor Panel · pulledCABIN FLOOR PANEL 241CF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED FLOOR PANEL 241CF FOUND WITHIN REPAIRABLE LIMITS OF SRM 53-00-50-2R-1 REPAIR 1;[02] PREPPED FLOOR PANEL 241CF FOR WET LAY-UP IAW B737-700 SRM 53-00-50-2R-1 REPAIR 1 STEPS 3 (A-K);[03] VERSDR SWAA2022072227916Floor Panel · pulledCABIN FLOOR PANEL 241BF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED FLOOR PANEL 241BF FOUND WITH IN REPAIRABLE LIMITS OF SRM 53-00-50-2R-1 REPAIR 1;[02] PREPPED FLOOR PANEL 241BF FOR WET LAY-UP REPAIR IAW B737-700 SRM 53-00-50-2R-1 REPAIR 1 STEP 3 (A-K);[SDR SWAA2022072127917Floor Panel · pulledCABIN FLOOR PANEL 231YF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP A; C; E-F. SDR SWAA2022072127918Floor Panel · pulledCABIN FLOOR PANEL 231XF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP A; C; E-F. SDR SWAA2022072127919Floor Panel · pulledCABIN FLOOR PANEL 241AF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP A; C; E-F. SDR SWAA2022031081272Megaphone · inoperativeA FLIGHT ATTENDANT MEGAPHONE INOP (FWD POS) / [01] R+R FWD F/A MEGAPHONE PER AMM 25-64-00.SDR SWAA2022011861538Light · brokenEMERGENCY EXIT LIGHT COVER BROKE OFF IN EMERGENCY EXIT ROW; COPTS SIDE ; / [01] R/R CAPT'S SIDE EMER EXIT ROW EMER EXIT LIGHT ASSY 33-51-01SDR SWAA2021120349526Panel · elongatedREF ID #TTG8Q009L8BP PANEL 194E HAS AN ELONGATED HOLE ON THE LEADING EDGE ; REF ID #TTG8Q009L8BP PANEL 194E HAS AN ELONGATED HOLE ON THE LEADING EDGE THE FIFTH FASTENER HOLE OVER CENTER OF PANEL MEASRING .400 AT LONGEST POINT AND .303 AT SMALLEST / [01] C/W EASDR SWAA2021120349196Panel · elongatedFASTENER HOLE ELONGATED ; FASTENER HOLE ELONGATED PNL 194E FWD #6 FROM OTOARD. THIS TASK STEP #7. / [01] REPAIRED PER AMM 20-6?11-210<BR>INSTALLATION OF TINNERMAN WASHER; [02] ABOVE REFERENCE IS INCORRECT. REFERENCE SHOULD BE AMM 20-60-11-201; [03] VERIFIED C/SDR SWAA2021020446153Transmitter · faultyDURING LANDING W/SELECTED FLAPS 15 DEGREES AND INDICATION SHOWED 5 DEGREES WE LOWERED THE FLAPS TO 15 DEGREES USING ALTERNATE FLAP SWITCH PER QRH. / FOUND FAULT CODE 27-52260 ON FSEU. PERFORMED FIM 27-51 TASK 820, DETERMINED TO BE INTERMITTENT FAULT R&R RIGHT SDR SWAA2021020446866Indicator · faultyDURING LANDING W/SELECTED FLAPS 15 DEGREES AND INDICATION SHOWED 5 DEGREES WE LOWERED THE FLAPS TO 15 DEGREES USING ALTERNATE FLAP SWITCH PER QRH. / FOUND FAULT CODE 27-52260 ON FSEU. PERFORMED FIM 27-51 TASK 820, DETERMINED TO BE INTERMITTENT FAULT. R&R RIGHTSDR SWAA2021021135804Shield · corroded***CORROSION*** AFT CARGO BAY ANGLE UNDER SHIELD BS 787-767 RBL 22 WL 155 / CORROSION ON AFT CARGO BAY ANGLE UNDER SHIELD AT BS 787 - 767; RBL22; WL155 FOUND OUT OF LIMITS DUE TO NO SRM LIMITS. REMOVED ANGLE; LOCATED & DRILLED NEW ANGLE AND INSTALLED NEW ANGLESDR SWAA2021021135805Web · corroded***CORROSION*** AFT CARGO BAY VERTICAL WEB BS 787- 767 RBL 22 WL 155 / CORROSION ON VERTICAL WEB BS787 - 767 RBL22 WL155 WAS FOUND TO BE OUT OF LIMIT DUE TO NO LIMITS ARE GIVEN IN THE SRM. REMOVED AND REPLACED WEB PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 AND BSDR SWAA2020123135803Stringer · crackedCRACKED STRINGER AT AREA AFT OF FWD CARGO BAY BS 540 S-26R WL 153, MARKED. REMOVED DAMAGED S-26R SECTION AND INSTALLED NEW S-26R SECTION BS 540-500D+6' AND SPLICE, IAW SRM 53-00-03-2R-1 DWG 143A1215; 143A3230.SDR SWAA2020123135802Stringer · crackedCRACKED STRINGER AT AREA AFT OF FWD CARGO BAY BS 540 S-27R WL 151, MARKED. REMOVED DAMAGED S-27R SECTION AND INSTALLED NEW S-27R SECTION (BS 540-500D+6') AND SPLICE, IAW SRM 53-00-2R-1 DWG 143A1215; 143A3230.
Back to N211WN