N229UA
Service difficulty reports · 151
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N229UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N229UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017071002151Battery Pack · inoperativeNO EMERGENCY LIGHTS, REPLACED THE BATTERY PACK M33409 IAW WDM 33-51-58 AND AMM 33-51-06-9 60-802.SDR CALA2017061901896Tube · crackedLEFT ENGINE EGT AND N1 EXCEEDANCE ON TAKEOFF. FOUND AS126 SENSE TUBE CRACKED. REPLACED THE TUBE IAW FIGURE 604, MM 72-00-00-290-829-N02 FOR 4090 ENGINE N1 WAS AT 105 FOR .4 SECONDS THIS IS IN AREA A IAW E3A NO INSPECTION NEEDED. IAW 72-00-00-290-828-N02, SUBSDR CALA2017040700913Unknown · malfunctionedAFTER LANDING ON ROLLOUT EMERG EXITS CYCLED ON OFF 3 TIMES FOR NO REASON. C/OUT EMERG LIGHTS OPERATIONAL TEST IAW AMM 33-51-00-710-801 SATIS. TOMC CONSULTED- NIL HISTORY OF DEFECT NOTED. SATIS TO CONTINUE.SDR CALA2017011300077Light · smokeSMOKE CAME OUT OF BOTH EYEBALL LIGHTS ABOVE R1 DOOR. TURNED OFF BOTH LIGHTS, PERFORMED INSPECTION IAW MM TASK 05-51-58-800-801C3. REPLACED THE LAMPS AND LIGHT ASSY.SDR CALA2015011993001Control Panel · misinstalledENGINE FIRE HANDLE PANEL INSTALLED UPSIDE DOWN. FIRE HANDLE POSITIONS REVERSED WITH GRAPHICS UPSIDE DOWN. REMOVED & REINSTALLED PANEL TO CORRECT POSITION. NO DISCREPANCIES NOTED WITH WIRE BUNDLES ROUTING. FIRE TESTS NORMAL AFTER REINSTALLATION.SDR CALA2014051691021Unknown · damagedBULK PIT FLOOR DAMAGED. DAMAGE REPORTED IS ON BULK CARGO PIT VACUUM WASTE SERVICE PANEL ACCESS DOOR & HAS A HOLE APPROXIMATELY 1 INCH IN DIAMETER.SDR CALA2014021090324Idg · malfunctionedELEC GEN SYS RT IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GEN CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. STATUS MESSAGE 01- LATCHED CLIMB MODE DEPENDENT, IDG RT FREQUENCY IS LOW, DB GCU RT. REPLACED GCU IAW MM 24 -22-0SDR CALA2014020690300Idg · disconnectedELEC GEN SYS RT IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. STATUS MESSAGE 01- LATCHED CLIMB MODE DEPENDENT, IDG RT FREQUENCY IS LOW. DB GENERATOR CONTROL UNIT RT. IDGSDR CALA2013120393401Sdu · faultySATCOM INOPERATIVE, PLACED SATCOM ON MEL IAW MEL 2315A. REPLACED SDU & ACCOMPLISHED SYS TEST. SATCOM CHECKED OK.SDR CALA2013100391721Relay · faultyTHE NITROGEN GENERATING SYSTEM DETECTS A FAULT SUCH AS LOW SYSTEM FLOW RATES OR HIGH OR LOW TEMPERATURE CONTROL RESULTING IN DEGRADED PERFORMANCE. NITROGEN GENERATING SYSTEM SHUTS DOWN BUT WILL AUTOMATICALLY RESET ONCE ON THE GROUND. REPLACED NITROGEN GENERATSDR CALA2013083090869Unknown · leakingNR 2 ENGINE HAS EVIDENCE OF ACTIVE LEAK AFTER A CHECK ENGINE RUN. LEAK IS AROUND TOP INBOARD LARGE FUEL LINE AT TOP OF FUEL PUMP. SUSPECT LINE IS REF"FUEL OIL COOLER TUBE. REMOVED NR 3 BEARING COMPARTMENT BREATHER RESTRICTOR VALVE & BREATHER MANIFOLD (LB02)SDR CALA2013082290654Status Message · activatedAPU CONTROL STATUS MESSAGE RECEIVED.SDR CALA2013081390410Gcu · faultyAPU GENERATOR WILL NOT COME ONLINE, ACCOMPLISHED RESET OF GENERATOR, NO HELP. REPLACED AGCU PER MM 24- 22-02 CHECKED OK.SDR UALA2013072305185Idg · faultedLEFT GENERATOR OFF EICAS MESSAGE. CYCLED GENERATOR SWITCH IAW FM PROCEDURE, NO HELP. ACCOMPLISHED FIM 24-22 TASK 811. REPLACED IDG IAW MM 24-11-01. ACCOMPLISHED TASK 71-00-00-800-801-N00. AND TASK 24-11-00-700-801. LEAK AND OPS CHECKED NORMAL.SDR UALA2013072605244Gcu · failedACFT RETURN TO THE BLOCKS. NO OUTPUT LEFT IDG. REPLACED LEFT GCU, OPS CHECKED GOOD.SDR UALA2013062404362Probe · failedRT ENGINE CONTROL IS IN A TIME LIMITED DISPATCH CONDITION. ENGINE CONTROL SYS IS OPERATING WITH REDUCED REDUNDANCY. REPLACED P2T2 PROBE IAW AMM 77-11-03-401. SN OFF-49912 SN ON-59301. LEAK CHECKED GOOD. IAW AMM 77-11-03-501, PERFORMED TEST NR 6 EEC IDLE CHECSDR UALA2013052803710Charger · faultyAPU WILL NOT START. MESSAGE FOR APU BATTERY CHARGER. APU BATTERY CHARGER REPLACED IAW AMM. APU ELECT START NORMAL.SDR UALA2013050603128Pump · leakingFUEL LEAKING FROM RT ENGINE. EVIDENCE OF FUEL LEAK FROM NR 5 FUEL PUMP DRAIN. APPROXIMATELY 16 DROPS PER MINUTE, NO LEAKS AFTER ENGINE SHUTDOWN. REPLACED NR 2 ENGINE FUEL PUMP PER MM. LEAK AND ENGINE RUN CHECKED GOOD.SDR UALA2013050603157Control Valve · damagedNR 2 ENGINE OUTBOARD TVBC VALVE INDICATOR PIN MISSING. REPLACED VALVE, OPS CHECKS PER MM 75-00-00.SDR UALA2013032501850Tube · leakingFUEL LEAK RIGHT ENGINE. FUEL LEAKING FROM FUEL DRAIN TUBE. RUN-UP ENG BY CREW, CHECKED. NO LEAKING FOUND AFTER ENG SHUT DOWN.SDR UALA2013031801599Solenoid · failedFLAPS PRIMARY FAIL PRIMARY (HYDRAULIC) FLAPS DRIVE FAILURE. FLAPS OPERATING IN SECONDARY (ELECTRIC) MODE. CAUTION MSG02- NOT ACTIVE CLIMB MODE DEPENDENT; FLAPS PRIMARY LOW SPEED SOLENOID CIRCUIT IS OPEN. DB- FSEU 2MSG-2720360 ACTIVE CL HARD MSG-2720372 INACSDR UALA2013021900998Skin · dentedDENT FOUND ON FUSELAGE NOT LISTED IN HISTORY. DENT WITHIN LIMITS PER SRM 53-00-01 PAGE 108. REMOVED DAMAGE. HFEC. FABRICATE AND INSTALL REPAIR PARTS IAW SRM 53-00-01 REPAIR 3 AND ECRA 5330-04440.SDR UALA2013012100358Metering Unit · malfunctionedWHILE DOING FUNCTIONAL TEST OF NOSE WHEEL STEERING, NOSE WHEELS TURNED LEFT AND RIGHT BUT WOULD NOT RETURN TO NEUTRAL, THEY STAYED AT 3 DEGREES TO THE RIGHT. COMPLETE NOSE LANDING GEAR SYSTEM TEST. AFTER ACFT IN HANGAR AND WARMED UP, NO PROBLEMS WERE NOTED. SDR UALA2013011600268Precooler · crackedNR 2 ENGINE PRECOOLER IS CRACKED AT INBOARD TOP. REMOVED PRECOOLER. COMPLETED UP TO MM36-11 15 P415 ITEM 3.F.8. AOG Q3435 8EA WASHERS PCN 754-2661 FOR 3EA SUPPORT LINKS WASHERS FOR UNDER NUTS ON LWR END. OLD PRECOOLER DID NOT HAVE DATA PLATE. COMPLETED INSSDR UALA2012120607060Wire · damagedWINDOW HEAT L FWD FAILURE OF LEFT NR 1 WINDSHIELD HEATING CIRCUIT (LOSS OF WINDOW COATING, WIRING OR THE INDIVIDUAL WHCU CIRCUIT FOR THAT WINDOW). REPAIRED WIRING FOR ANTI-ICE SNSR RETURNED TO ORIGINAL CONF. PER WD30-41-11 BY FILE 063635.SDR UALA2012101705928Circuit Card · unsecureELMS P210 PANEL THE ELECTRICAL LOAD MANAGEMENT SYSTEM (ELMS) P210 PANEL IS FAULTED SUCH THAT IT CANNOT SUPPORT AIRPLANE DISPATCH. AIMS HAS LOTS ARINC 629 COMMUNICATION WITH THE P210 PANEL. OR ONE P210 PANEL CHANNEL IS LOST AND THE OTHER FAULTED AND IS OPERATISDR UALA2012091405199Fan · faultySMOKE SMELL NEAR DOOR 3L. TURNED OFF UPPER RECIRC. AFTER SELECTING UPPER RECIRC FAN SWITCH OFF CREW WAITED TO REE VALUATE AND REPORTS ODOR HAS CLEARED. ELECTRICAL TYPE ODOR NO VISIBLE SMOKE, CONCENTRATED NEAR DOOR 3L-3R AREA. FOUND C-B B5 AT P210 POPPED AFSDR UALA2012082804839Panel · faultyELMS P210 PANEL THE ELECTRICAL LOAD MANAGEMENT SYSTEM (ELMS) P210 PANEL IS FAULTED SUCH THAT IT CANNOT SUPPORT AIRPLANE DISPATCH. ELEC SYNOPTIC PAGE SHOWS NR 2 ELEC GEN NOT POWERING R MAIN BUS, R UTILITY BUS AND R TXFR BUS ALONG WITH BOTH BTB'S ISOLATED. SEVSDR UALA2012011600337Controller · faultyAPU SHUT DOWN AT GATE APU STATUS MSG. APU CONTROLLER REPLACED.SDR UALA2012010600146Controller · malfunctionedAPU AUTO SHUTDOWN TWICE AT GATE. RESET APU CONTROLLER, STARTED APU 5 TIMES, STARTED ENGINES USING APU PNEUMATICS. NO FAULTS IN CMC.SDR UALA2012010600140Engine · overtempECM PARAMETER SHIFT HIGH EGT. REPLACED NR 1 ENGINE RAN ENGINE, NO DEFECTS NOTED.SDR UALA2012010300051Apu · shutdownAPU AUTO SHUTDOWN. REPLACED OIL CLUSTER-OIL FILTER ELEMENTS. CLEANED CONNECTOR TO OIL TEMP SENSOR AT OIL LUBRICATION CLUSTER AND OIL QUANTITY-SUMP TEMP SENSOR AT OIL TANK. WASHED OUT AIR-OIL COOLER ALSO. SERVICED APU OIL AND ACCOMPLISHED APU OPERATIONAL CSDR UALA2011122107054Anti-Ice Valve · inoperativeLEFT ENGINE ANTI ICE VALVE INOPERATIVE.SDR UALA2011122107036Unknown · malfunctionedAPU SHUTDOWN APU AUTO-SHUTDOWN HAS OCCURRED. REFERENCE LOGIC DESCRIPTION FOR DETAILS (ADVISORY). CREW COMMENTS: APU AUTO SHUT DOWN 2 TIMES. MAINT IS SHOWING APU HIGH OIL TEMP. 100C ON SCREEN. MAINT MESSAGE 49-10260. -INF- :REF FIM 49-20 TASK 801 FOR HIGH SDR UALA2011120506683Engine · making metalNR 1 ENGINE, HAS THREE PIECES OF METAL ON THE CHIP DETECTOR.SDR UALA2011111506257Solenoid · faultyRIGHT GEAR WON'T CLOSE. MAINT TEXT: TEXT SHOULD READ: RT MAIN LANDING GEAR DOOR WILL NOT CLOSE. REPLACED RIGHT MAIN GEAR DOOR RELEASE-SAFETY VALVE MODULE SOLENOID PER MM, OPS CHECKS GOOD.SDR UALA2011110105903First Aid Kit · missingFIRST CLASS FIRST AID KIT MISSING. INSTALLED FIRST AID KIT.SDR UALA2011103105888Switch · faultyLEFT PNUEMATIC ISOLATION VALVE SWITCH LEGEND WILL NOT SHOW "AUTO" WHEN DEPRESSED. REPLACED LEFT PNUEMATIC ISOLATION VALVE SWITCH & BASE ASSY, OPS TEST OK.SDR UALA2011103105880Medical Kit · missingFIRST CLASS FIRST AID KIT MISSING. THIS AIRCRAFT SEEMS TO HAVE HAD THE KIT OVERLOOKED DURING THE IPTE MOD. THERE IS NO CLOSET INSTALLED, RATHER, THERE IS A DRAWER AT 1LT AT FLOOR LEVEL THAT CONTAINS NUMEROUS EMERGENCY EQUIPMENT BUT HAS NO PROVISIONS OR PLACASDR UALA2011103105887Shutoff Valve · faultySTS MSG C ISO VLV. XFER TO MEL. -INF- :BLEED ISLN VALVE C STATUS MSG. REMOVED AND REPLACED CENTER ISOLATION S-O VALVE, MR36127-146 ON, -158 OFF. MESSAGE NO LONGER SHOWS ACTIVE, SYS OPS SATISFACTORY.SDR UALA2011093005310Diode · faultyEICAS MESSAGE: "ELEC STBY SYS". REPLACED TB405 POS 12 DIODE. MESSAGE CLEARED AND POWER UP NORMAL. OP CHECKED GOOD.SDR UALA2011093005308Diode · malfunctionedRAT INADVERTENTLY DEPLOYED, WHILE RESETTING CB'S IN ELMS P310 PSU-A&B PRIM (B4-C7) AND ELMS P310 PSU-A&B ALTN (J5-K5). RAT RETRACTED PER AMM. ITEM WORK WITH EG6198 FOR OPERATIONAL TEST. REPLACED TB405 POS 12 DIODE ACCOMPLISHED FIM TASK 24-09-TASK 819 AND RASDR UALA2011092105112Fairing · damagedKEEL BEAM FAIRING 149BL HAS DAMAGE.SDR UALA2011092005086Relay · faultyELEC STANDBY SYS MESSAGE. REPLAC'E K24006 MAIN BATTERY RELAY, NO HELP. REPLACED RELAYS K24020 & K24019, NO HELP. ABOVE SHOULD READ RELAY K24006 NOT K24020. PRIOR TO 2ND TEST HOP, WITH AC POWERED UP FROM BATTERY ONLY, AFTER APU PWR SUPPLIED, GOT 'ELEC STANDSDR UALA2011091204946Computer · faultyPFC LANE FAULT 27-14012. BOEING AHM PROGRAM HAS DETECTED REPEAT FAULT MSG 27-14012 PFC R LANE 1 FAULT. REPLACE THE PFC-R (483-9216) PER MM, CONFIRM PFC SOFTWARE IS CORRECT FOR ALL 3 PFC'S. ACP PFC LANE RESET TEST TWICE TO UNLATCH REMAINING FAULTS. IF PFC-R SDR UALA2011091204945Module · faultyFLIGHT CONTROL CAUTION MESSAGE ON UPPER EICAS, CLEARS WITH PFC SELF TEST, REAPPEARS WITH THIRD HYS SYSTEM. TS INSTALLED NEW HYDIM CL AND CR REF MM, NO HELP. REPLACED HYDIM CR MODULE, OPS CK GOOD.SDR UALA2011081904418Rfu · malfunctionedSATCOM HI GAIN. HIGH GAIN VOICE INOP, LOW GAIN SYSTEM OPERATES NORMALLY. MAINT MESSAGE 23-60091 FAULTED LNA-DIPLEXER FOR LGA HAS A FAULT. REPLACED RF UNIT PER MM.SDR UALA2011081104224Display · inoperativeBOTH HIGH & LOW GAIN INOPERATIVE SATCOM. REPLACED SDU PER MM, ALL OKAY.SDR UALA2011081104223Rfu · malfunctioned"SATCOM SYS" DISPLAYED ON LOWER SCREEN. REPLACED SATCOM RADIO FREQUENCY UNIT, TESTED OKAY.SDR UALA2011080304049Coupler · faultyLEFT HF RADIO WILL RECEIVE BUT NOT TRANSMIT. NO TIME ON SHORT TURN TO WORK OR T/S. -INF-:. PER AHM LEFT ANTENNA COUPLER HAS INTERNAL FAULT. PCN 530-9045, PLZ CHECK WITH ON LINE I PC FOR PROPER EFFECTIVITY. SAMC MO. REPLACED LEFT HF TR, BITE TEST AND VOICE