N231JQ

Service difficulty reports · 51

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N231JQ' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR R61A2025090200379Stringer · corrodedAFT CARGO STRINGER 29R AT FR 79-81 IS CORRODED. REPAIRED AFT CARGO STRINGER 29R AT FR79-81 PER ETD2025-170-926612 REV A.Aug 22, 2025 · N231JQ · Emb ERJ170100LR · Fuselage Main, Longeron/StringerSDR R61A2025090200380Stringer · corrodedSTRINGER 28R CORRODED AT FRAME 86/87. REPAIRED STRINGER 28R FR 83-90. REF:ETD2025-170-926813Aug 17, 2025 · N231JQ · Emb ERJ170100LR · Fuselage Main, Longeron/StringerSDR R61A2022111500707Beam · corrodedFWD PAX DOOR (L1) LOWER BEAM CORRODED AT THE FWD AND AFT SLIDE FITTINGS. REMOVED AND REPLACED FWD PAX DOOR (L1) LOWER BEAM. REF SRM 51-40-08Oct 26, 2022 · N231JQ · Emb ERJ170200LR · Fuselage Main, StructureSDR R61A2022111500706Shear Tie · corrodedSHEAR CLIP CORRODED AT FRAME 88 STRINGER 27R-26R. : REMOVED AND REPLACED SHEAR CLIP AT FR 88 STGR 27R-28R. REF EMB SRM 51-40-02Oct 26, 2022 · N231JQ · Emb ERJ170200LR · Fuselage Internal Mounting StructureSDR R61A2022111000694Beam · corrodedFWD SERVICE DOOR (R1) LOWER BEAM CORRODED AT THE FWD AND AFT SLIDE FITTINGS. REMOVED & REPLACED LOWER BEAM AT FWD SERVICE DOOR PER REF SRM 51-40-08.Oct 26, 2022 · N231JQ · Emb ERJ170200LR · Fuselage Main, StructureSDR R61A2022111000693Shear Tie · corrodedSHEAR CLIP CORRODED AT FRAME 89 STRINGER 29L-29R. REMOVED AND REPLACED SHEAR CLIP AT FR 89 BETWEEN STGRS 29L-29R. REF SRM 51-40-08.Oct 26, 2022 · N231JQ · Emb ERJ170200LR · Fuselage Internal Mounting StructureSDR R61A2022111000692Shear Tie · corroded"SHEAR CLIP CORRODED AT AFT SIDE OF FRAME 85 BETWEEN STRINGERS 29L-28L, REMOVED AND REPLACED SHEAR CLIP AT FR 85 BETWEEN STRGS 27L-28L. REF SRM 51-40-08. LOCATION WAS CORRECTED ON EAMS WO H8844 SN 231 TASK 3. LOCATION COPRRECTION: CORRODED SHEAR CLIP IS AT FOct 26, 2022 · N231JQ · Emb ERJ170200LR · Fuselage Internal Mounting StructureSDR R61A2022111000691Shear Tie · corrodedSHEAR CLIP CORRODED AT FRAME 84 STRINGERS 28L-27L, REMOVED AND REPLACED SHEAR CLIP AT FRAME 84 STRINGERS 28L-27L. REF EMB SRM 51-40-08Oct 26, 2022 · N231JQ · Emb ERJ170200LR · Fuselage Internal Mounting StructureSDR R61A2022111000690Shear Tie · corrodedSHEAR CLIP CORRODED AT FRAME 83 STRINGERS 28R-27R, REMOVED AND REPLACED SHEAR CLIP FRAME 83 STRINGERS 28R-27R. REF EMB SRM 51-40-08Oct 26, 2022 · N231JQ · Emb ERJ170200LR · Fuselage Internal Mounting StructureSDR R61A2022111600710Doubler · crackedRH WING LOWER SKIN HAS SUSPECTED CRACK O/B OF RIB 5 DOUBLER. PERFORMED TEMPORARY REPAIR ON RH WING LOWER SKIN CRACK REF ETD2022-170-033203 (CORRECTION TO DISCREPANCY LOCATION: OTBD OF RIB 4A)Oct 24, 2022 · N231JQ · Emb ERJ170200LR · Wing, Plate/SkinSDR R61A2021100500783Hinge · lack of lubeL1 DOOR HAVING DIFFICULTIES OPENING. CLEANED AND LUBED L1 DOOR UPPER FLAPPER HINGE AND OPS CHECK IAW AMM 52-11-00.Oct 2, 2021 · N231JQ · Emb ERJ170200LR · Fuselage, Door HingeSDR R61A2021082500670Bleed Valve · faultyBLEED 2 OVERPRESSURE MESSAGE AFTER TAKE-OFF. RAN QRH PROCEDURE, NO FIX RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MAINTENANCE PLACED BLEED 2 ON MEL AND RETURNED THE AIRCRAFT TO SERVICE. THE RIGHT HAND NAPRSOV WAS REPLACED IN LGA ON 8/24/2021 CLEARING THAug 22, 2021 · N231JQ · Emb ERJ170200LR · Compressor Bleed ValveSDR R61A202002220221Mount · corrodedDURING HEAVY CHECK MAINTENANCE FOUND FWD TO MIDDLE BELLY FAIRING MOUNT FLANGE CORRODED AS MARKED. REMOVED CORROSION ON FWD TO MIDDLE BELLY FAIRING MOUNT FLANGE REF SRM 51-10-03. MATERIAL REMOVED 0.028". OUT OF LIMITS REF SRM 53-04-02. INSTALLED NEW BELLY FAIRFeb 2, 2020 · N231JQ · Emb ERJ170200LR · Aerodynamic FairingsSDR R61A202001250055Splice · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION DAMAGE AFT WET AREA ON INTERCOSTAL SPLICE AT FRAME 90 BETWEEN TRACK BEAMS. REMOVED AND REPLACED AFT WET AREA ON INTERCOSTAL SPLICE AT FRAME 90 BETWEEN TRACK BEAM REF SRM 51-40-02, 51-40-08, APPLIED TOP COAT AT NEJan 20, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250073Mount · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION ON LH MONUMENT MOUNT IN FWD WET AREA FR 16 DIRECTLY INBD OF LEFT SILL. REMOVED DAMAGED LH MONUMENT MOUNT IN FWD WET AREA FR 16 DIRECTLY INBD OF LEFT SILL AND INSTALLED A NEW ONE IN REF. TO SRM 51-40-08.TOP COATEDJan 12, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Main, Attach FittingsSDR R61A202001250072Panel · corrodedDURING HEAVY CHECK MAINTENANCE FOUND PANEL 1431 DL 3EA L PROFILES HAVE CORROSION. REMOVED DAMAGED L PROFILES FROM PNL 1431DL.AND INSTALLED 3 EA NEW ONES. REF EMB SRM 51-40-08. A/C REMAINS IN CHECK.Jan 12, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250071Support Angle · corrodedDURING HEAVY CHECK MAINTENANCE FOUND SUPPORT ANGLE CORRODED BETWEEN FR87R & FR 86R, BETWEEN STGR 28R & STGR 27R. REMOVED AND REPLACED SUPPORT ANGLE BETWEEN FR87R & FR 86R AND STGR28R & STGR 27R REF SRM 51-40-08, AND RESTORED SURFACE PROTECTION REF SRM 51-23-0Jan 10, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250069Doubler · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION ON FWD WET AREA FLOOR DOUBLER OTBD OF LEFT TRACK AT FR 16 AS MARKED. REMOVED FLOOR DOUBLER. O/B OF LEFT TRACK AT FRAME 16 (FWD WET AREA),FABBED NEW FLOOR DOUBLER AND INSTALLED REF EMB SRM 51-40-08. TREATED, PRIMEJan 10, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Floor PanelSDR R61A202001310140Support Angle · corrodedWHILE IN HEAVY CHECK FOUND SUPPORT ANGLE CORRODED BETWEEN FR87R & FR 86R, BETWEEN STGR 28R & STGR 27R UPON FURTHER INVESTIGATION. FOUND SUPPORT ANGLE BETWEEN FR87R & FR 86R, BETWEEN STGR 28R & STGR 27R TO BE 100% MATERIAL LOSS. CORROSION DIMENSIONS: H-100% LJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310139Gusset · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA ON GUSSET AT FRAME 90 AND INTERCOSTAL OUTBOARD OF RH TRACK BEAM. REMOVED LOCATED AND DRILLED NEW AFT WET AREA GUSSET AT FRAME 90 AND INTERCOSTAL OUTBOARD OF RH TRACK BEAM REF SRM 51-40-02, 51-40-08, APPLIED ALOJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310138Gusset · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA ON GUSSET AT FRAME 90 AND RH TRACK BEAM.REMOVED LOCATED AND DRILLED NEW AFT WET AREA ON GUSSET AT FRAME 90 AND RH TRACK BEAM REF SRM 51-40-02, 51-40-08, APPLIED ALODINE ON HOLES & RIVETS REF SRM 51-23-04. INSTAJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Structure (General)SDR R61A202001310137Gusset · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA ON GUSSET AT FRAME 90 AND INTERCOSTAL OUTBOARD OF LH TRACK BEAM. REMOVED CORROSION BY BLENDING ON GUSSET AT FRAME 90 AND INTERCOSTAL OUTBOARD OF LH TRACK BEAM (AFT WET: H-100% LOSS L-.757" W-.174" NOMINAL .040"Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310136Seat Track · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA ON RH TRACK BEAM UPPER SHEET JUST FWD OF FRAME 86. REMOVED CORROSION BY BLENDING AT RH TRACK BEAM UPPER SHEET(AFT WET AREA) MATERIAL REMOVED: H-100% LOSS L-.619" W-.294" NOMINAL .063" OUT OF LIMITS. REF EMB SRJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR R61A202001310135Shear Panel · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA ON RH SHEAR PANEL. PN 170-91919-001 REMOVED AFT WET AREA RH SHEAR PANEL, REF. SRM 51-40-08. LOCATED, DRILLED, DEBURRED, AND ALODINED(PO#243626) NEW RH SHEAR PANEL, REF. SRM 51-40-02 & 51-23-04. INSTALLED AFT WEJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310134Shear Panel · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA IN MIDDLE OF CENTER SHEAR PANEL. REMOVED AFT WET AREA CENTER SHEAR PANEL, REF. SRM 51-40-08. LOCATED, DRILLED, DEBURRED, AND ALODINED (PO#243626) NEW CENTER SHEAR PANEL, REF. SRM 51-40-02, AND SRM 51-23-04. INSJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310133Support · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA RH PANEL SUPPORT AT FRAME 89. REMOVED AFT WET AREA RH PANEL SUPPORT AT FRAME 89, REF. SRM 51-40-08. LOCATED, DRILLED, DEBURRED, AND ALODINED(PO#243626) NEW RH PANEL SUPPORT AT FRAME 89, REF. SRM 51-40-02, AND SJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310132Mount · corrodedWHILE IN HEAVY CHECK FOUND CORROSION ON LH MONUMENT MOUNT IN FWD WET AREA FR 16 DIRECTLY INBD OF LEFT SILL REMOVED DAMAGED LH MONUMENT MOUNT IN FWD WET AREA FR 16 DIRECTLY INBD OF LEFT SILL IN REF. TO SRM 51-40-08. DRILLED UP NEW LH MONUMENT MOUNT IN FWD WET AJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Main, Attach FittingsSDR R61A202001310131Profile · corrodedWHILE IN HEAVY CHECK FOUND 1431DL L PROFILES HAVE CORROSION, LEFT WHEEL WELL ACCESS PANEL REMOVED DAMAGED L PROFILES FROM PNL 1431DL. REF EMB SRM 51-40-08. INSTALLED L PROFILES TO PANEL 1431DL. REF EMB SRM 51-40-08 AMM 20-10-01 TC2 7398 CAL DUE 6-10-20Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310130Doubler · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA ON RH DOUBLER AT FRAME 84. REMOVED RH DOUBLER AT FRAME 84(AFT WET AREA) IN REF. SRM 51-40-08 INSTALLED NEW RH DOUBLER AT FRAME 84(AFT WET AREA) IN REF. SRM 51-40-08.Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Main, StructureSDR R61A202001310129Shear Panel · corrodedWHILE IN HEAVY CHECK FOUND SHEAR CLIP CORRODED AT FR88 BETWEEN STGR 28R & STGR 27R REMOVED CORRODED SHEAR CLIP AT FR88 BETWEEN STGR 28R & STGR 27R REF SRM 51-40-08 INSTALLED NEW SHEAR CLIP AT FR88 BETWEEN STGR 28R &STGR 27R REF SRM 51-40-08, AND RESTORED SURFJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310128Doubler · corrodedWHILE IN HEAVY CHECK FOUND CORROSION ON FWD WET AREA FLOOR DOUBLER OTBD OF LEFT TRACK AT FR 16 AS MARKED REMOVED FLOOR DOUBLER. O/B OF LEFT TRACK AT FRAME 16 (FWD WET AREA). REF EMB SRM 51-40-08 INSTALLED NEW FLOOR DOUBLER. O/B OF LEFT TRACK AT FRAME 16 (FWD WJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310127Crossbeam · corrodedWHILE IN HEAVY CHECK FOUND FRAME 14 CROSSBEAM CORRODED @ TWO AREAS OTBD OF TRACK RIGHT. REMOVED DAMAGED BY BLENDING AT FWD WET AREA RH CROSSBEAM FR14 DIMENSIONS L=5 X W=1 X H=.032,.044IN. NOMINAL THICKNESS .120 ALLOWABLE DAMAGE 10% FOUND TO BE OUT OF LIMITS REJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Main, StructureSDR R61A202001310126Doubler · corrodedWHILE IN HEAVY CHECK FOUND SILL RIGHT CORRODED IN FOUR AREAS BETWEEN FRAMES 13/14. REMOVED RH FLOOR DOUBLER BETWEEN FRAMES 13-14. REF EMB SRM 51-40-08 INSTALLED NEW RH FLOOR DOUBLER BETWEEN FRAMES 13-14. REF EMB SRM 51-40-08Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310125Support · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA ON RH PANEL SUPPORT AT FRAME 84. REMOVED LOCATED AND DRILLED AT AFT WET AREA ON RH PANEL SUPPORT AT FRAME 84 REF SRM 51-40-02, 51-40-08 APPLIED ALODINE HOLES RIVETS SRM 51-23-04 PO# 243026 INSTALLED NEW AFT WEJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310124Shear Panel · corrodedWHILE IN HEAVY CHECK FOUND PAINT DAMAGE AFT WET AREA ON LH SHEAR PANEL AROUND BARREL NUT HOLE.. REMOVED AFT WET AREA LH SHEAR PANEL, REF. SRM 51-40-08. LOCATED, DRILLED, DEBURRED, AND ALODINED(PO#243626) NEW LH SHEAR PANEL, REF. SRM 51-40-02, AND SRM 51-23-04 Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001310123Seat Track · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA ON GUSSET AT FRAME 90 AND LH TRACK BEAM. REMOVED GUSSET AT FRAME 90 (AFT WET AREA) LOCATED AND DRILLED , APPLIED ALODINE ON HOLES RIVETS GUSSET AT FRAME 90 (AFT WET AREA). REF EMB SRM 51-40-08, SRM 51-40-02 ,SRJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR R61A202001310122Splice · corrodedWHILE IN HEAVY CHECK FOUND PAINT DAMAGE AFT WET AREA ON INTERCOSTAL SPLICE AT FRAME 90 BETWEEN TRACK BEAMS. REMOVED LOCATED AND DRILLED NEW AFT WET AREA ON INTERCOSTAL SPLICE AT FRAME 90 BETWEEN TRACK BEAM REF SRM 51-40-02, 51-40-08 APPLIED ALODINE AREA SRM 51Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250075Support · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA LH PANEL SUPPORT NEAR FRAME 90. REMOVED DAMAGED AFT WET AREA LH PANEL SUPPORT NEAR FRAME 90. LOCATED, DRILLED AND INSTALLED NEW PANEL SUPPORT. SURFACE PROTECTION APPLIED. REF EMB SRM 51-40-02, 51-40-Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250070Shear Tie · corrodedDURING HEAVY CHECK MAINTENANCE FOUND SHEAR CLIP CORRODED AT FR88 BETWEEN STGR 28R & STGR 27R. REMOVED AND REPLACED SHEAR CLIP AT FR- 88 BETWEEN STGR 28R &STGR 27R REF SRM 51-40-08, AND RESTORED SURFACE PROTECTION REF SRM 51-23-06 AND APPLIED CIC REF CPM 51-25Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Internal Mounting StructureSDR R61A202001250066Support · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA ON RH PANEL SUPPORT AT FRAME 84. REMOVED AND REPLACED AFT WET AREA ON RH PANEL SUPPORT AT FRAME 84 REF SRM 51-40-08,APPLIED TOP COAT AT NEW AFT WET AREA ON RH PANEL SUPPORT AT FRAME 84 REF SRM 51-23-Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250065Doubler · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA ON RH DOUBLER AT FRAME 84. REMOVED DAMAGED RH DOUBLER AT FRAME 84(AFT WET AREA). LOCATED, DRILLED AND INSTALLED NEW RH DOUBLER AT FRAME 84(AFT WET AREA). SURFACE PROTECTION APPLIED. REF. SRM 51-40-0Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Main, StructureSDR R61A202001250064Shear Panel · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION DAMAGE AFT WET AREA ON LH SHEAR PANEL AROUND BARREL NUT HOLE. REMOVED AND REPLACED REMOVED AFT WET AREA LH SHEAR PANEL, REF. SRM 51-40-08, APPLIED SURFACE PROTECTION TO FASTENERS WITH PAINT/TOPCOAT REF. SRM 51-23Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250063Gusset · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA ON GUSSET AT FRAME 90 AND INTERCOSTAL OUTBOARD OF RH TRACK BEAM. REMOVED AND REPLACED AFT WET AREA ON GUSSET AT FRAME 90 AND INTERCOSTAL OUTBOARD OF RH TRACK BEAM REF SRM 51-40-02, 51-40-08. A/C REMAJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250062Gusset · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA ON GUSSET AT FRAME 90 AND RH TRACK BEAM. REMOVED AND REPLACED AFT WET AREA ON GUSSET AT FRAME 90 AND RH TRACK BEAM REF SRM 51-40-02, 51-40-08. A/C REMAINS IN CHECK.Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250061Gusset · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA ON GUSSET AT FRAME 90 AND LH TRACK BEAM. REMOVED AND REPLACED GUSSET AT FRAME 90 (AFT WET AREA). REF EMB SRM 51-- 40-08, APPLIED TOP COAT AT NEW GUSSET AT FRAME 90 (AFT WET AREA). REF EMB SRM 51-23-0Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250060Gusset · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA ON GUSSET AT FRAME 90 AND INTERCOSTAL OUTBOARD OF LH TRACK BEAM. REMOVED AND REPLACED AFT WET AREA ON GUSSET AT FRAME 90 AND INTERCOSTAL OUTBOARD OF LH TRACK BEAM REF SRM 51-40-02, 51-40-08. A/C REMAJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250059Seat Track · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA ON RH TRACK BEAM UPPER SHEET JUST FWD OF FRAME 86. REMOVED AND REPLACED AFT WET AREA RH TRACK BEAM UPPER SHEET JUST FWD OF FRAME 86 REF SRM 51-40-08. RESTORED SURFACE PROTECTION PER SRM 51-23-06. A/CJan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR R61A202001250058Shear Panel · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA ON RH SHEAR PANEL. REMOVED AND REPLACED AFT WET AREA RH SHEAR PANEL, REF. SRM 51-40-08. A/C REMAINS IN CHECK.Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250057Shear Panel · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA IN MIDDLE OF CENTER SHEAR PANEL. REMOVED AFT WET AREA CENTER SHEAR PANEL, REF. SRM 51-40-08. LOCATED, DRILLED, DEBURRED, AND ALODINED(PO#243626) NEW CENTER SHEAR PANEL, REF. SRM 51-40-02, AND SRM 51-Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A202001250056Support · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA RH PANEL SUPPORT AT FRAME 89. REMOVED AND REPLACED AFT WET AREA RH PANEL SUPPORT AT FRAME 89, REF. SRM 51-40-08. A/C REMAINS IN CHECK.Jan 9, 2020 · N231JQ · Emb ERJ170200LR · Fuselage Miscellaneous Structure
Back to N231JQ