N327UP
Service difficulty reports · 168
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N327UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N327UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA201310070495Skin · dentedC08 INSPECTION, T/E WEDGE LOWER SKIN OF RT WING INBD AFT FLAP AT IFS 141 DENTED. REPAIRED IAW SRM 57-53-01-2R-1, FIG 201,REV 57.00, 2, SRM 51-70-10-2R-4 FIG 201 SHEET 3, REV.57.00, 3. & SRM 51-70-03-0G, REV.57.00.SDR IPXA201310070494Floor Panel · damagedC08 INSPECTION, FOUND DAMAGE ON M/D CARGO FLOOR PANEL 241HFF, AT BS 833-929, LBL 37-39. FABRICATEED FLOOR PANEL IAW EO NR B767-5320-9693-H AND COMPLETE POTTED INSERT INSTALLATION IAW DWG 145T5876, REQUIREMENTS.SDR IPXA201310070493Floor Panel · crackedC08 INSPECTION, FOUND M/D CARGO FLOOR PANEL 241CFF CRACKED AT BS 731-833, LBL 37-39. FABRICATED FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA201310070492Floor Panel · crackedC08 INSPECTION, FOUND M/D CARGO FLOOR PANEL 231HFF CRACKED AT BS 629-654+22, LBL 37-39. FABRICATE THE FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA201310070491Floor Panel · damagedC08 INSPECTION, FOUND DAMAGE ON M/D CARGO FLOOR PANEL 231TFF AT BS 687-731,LBL 37-39. FABRICATED THE FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA201310070490Floor Panel · crackedC08 INSPECTION, FOUND DAMAGE ON M/D CARGO FLOOR PANEL AT BS 654+22-686, LBL 37-39. . FABRICATED FLOOR PANEL IAW EO NR B767-5320-9693-H.SDR IPXA201310070489Floor Panel · damagedC08 INSPECTION, FOUND DAMAGE ON M/D CARGO FLOOR PANEL AT BS 929-970.5, LBL 37-39. FABRICATED FLOOR PANEL IAW EO NO B767-5320-9693-H AND COMPLETE POTTED INSERT INSTALLATION IAW DWG 145T5876.SDR IPXA201310070488Floor Panel · brokenC08 INSPECTION, FOUND BROKEN ON M/D CARGO FLOOR PANEL 241PFF AT BS 969.5-971, LBL 61.5-62.5. FABRICATE FLOOR PANEL IAW EO NT B767-5320-9693-H AND COMPLETE INSERT INSTALLATION IAW DWG 145T5876.SDR IPXA2674405Skin · dentedRT WING INBD AFT FLAP DENTED. REPAIRED IAW EO B767-5750-47002-B.SDR IPXA2674404Skin · dentedLT WING INBD T/E FLAP DENTED. REPAIRED IAW EO B767-5750-47001-B.SDR IPXA1670732Unknown · unknownETOP AFTER TAKEOFF, HEARD AN UNIDENTIFIED WIND NOISE FROM THE AREA OF THE CREW ENTRY DOOR AREA. COMMUNICATION DIFFICULT DUE TO THE NOISE. INSPECTED MAIN ENTRY DOOR SEAL, CARGO DOOR SEAL, FWD ACCESS DOOR SEAL AND E&E DOOR SEAL, NO DEFECTS NOTED. INSPECTED FWDSDR IPXA11670303Fairing · delaminatedINSPECTION TYPE:C, RT WING INBD MAIN FLAP OTBD L/E FAIRING DELAMINATED. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05, PAR 5A(1), FIG 5, REV 5.1.SDR IPXA1670221Floor Panel · dentedINSPECTION TYPE:7C, MCD FLOOR PANEL FOUND 28 DENTS AND 5 PUNCTURES AT BS 540 TO 654+22, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-06.SDR IPXA1670268Floorbeam · corrodedINSPECTION TYPE:7C, BULK CARGO COMPT STA1540 LBL 78" M/D FLOORBEAM AFT LWR FLANGE FOUND CORRODED. BULK CARGO COMPT STA 1540, LBL 78" M/D FLOORBEAM REPAIRED IAW HX RS NR R-53-65-37253, REV A AND EO NR B767-5310-44990-A, ORIGINAL MATERIAL IS BAC 1506-4177-7075TSDR IPXA1670220Floor Panel · dentedINSPECTION TYPE:7C, MCD FLOOR PANEL FOUND 12 DENTS AND 5 PUNCTURES AT BS 283 TO 412 , LBL 11 TO RBL 11. NEW FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-H AND INSTALLED AS PER AMM 53-01-06.SDR IPXA1670219Floor Panel · dentedINSPECTION TYPE:7C, MCD FLOOR PANEL FOUND 16 DENTS AND 4 PUNCTURED AT BS 540 TO 654+22, LBL 11 TO RBL 11. NEW FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-06.SDR IPXA11670158Stiffener · crackedINSPECTION TYPE:7C, WING CTR TANK FRONT SPAR VERTICAL STIFFENER TOP AREA FOUND CRACKED JUST AT STA 785.9, LBL 32.94 WING CTR TANK FRONT VERTICAL STIFFENER REPAIRED IAW SRM 57-10-10-2R2, REPAIR 2, FIG 201, REV 51 JUST AT STA 785.9 LBL 32.94, ORIGINAL MATERIAL ISDR IPXA0663696Panel · damagedREF D439829, POSITION 4, DAMAGE 5" FROM RT SIDE PANEL AND 5' FROM A FT EDGE. FABRICATED AND REPLACED PANEL IAW EO B767-5320-9693-G.SDR IPXA10658772Seal · deterioratedFL 320 LOUD THUD FOLLOWED BY DEAFENING LOUD HOWL. INCREASING & DECREASING PSI, CHANGED ALTITUDE, NOISE DID NOT CHANGE. DIFFICULT TO COMMUNICATE WITH EACH OTHER AND AR DUE TO NOISE. NOISE STOPPED AS DESCENDING THRU FL220. CHECKED FLT COMPT FOR AIR LEAK, FOUNDSDR IPXA10658388Skin · erodedINSPECTION TYPE:6C, LT WING INBD AFT FLAP INBD FWD (NEAR L/E) FOUND ERODED AND WORN METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R REPAIR.4 FIG 202 SHEET 1 REV.46.SDR IPXA10658300Floor Panel · delaminatedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DELAMINATION AND PUNCTURED AT STA731 TO 833 LBL11 TO RBL11. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658353Floor Support · crackedINSPECTION TYPE:C, MAIN DECK COMPT STA 1581 RBL 70" FLOOR PANEL SUPPORT INBD ANGLE FOUND CRACKED. MAIN DECK COMPT STA1581 RBL70" FLOOR PANEL SUPPORT INBD ANGLE REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02 REV 46.SDR IPXA10658352Floor Support · deformedINSPECTION TYPE:C, BULK CARGO COMPT STA 1415 LBL 30" FLOOR PANEL SUPPORT SURFACE FOUND DEFORMED. FLOOR PANEL SUPPORT REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02, REV 46.SDR IPXA10658351Stiffener · deformedINSPECTION TYPE:C, BULK CARGO COMPT STA 1481 LBL 8" FLOOR PANEL SUPPORT VERTICAL STIFFENER FOUND DEFORMED. BULK CARGO COMPT STA1481 LBL8" FLOOR PANEL SUPPORT VERTICAL STIFFENER REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02 REV 46.SDR IPXA10658350Stiffener · deformedINSPECTION TYPE:C, BULK CARGO COMPT STA 1502 LBL 8" FLOOR PANEL SUPPORT VERTICAL STIFFENER FOUND DEFORMED. BULK CARGO COMPT STA1502 LBL8" FLOOR PANEL SUPPORT VERTICAL STIFFENER. REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02 REV 46.SDR IPXA10658349Stiffener · deformedINSPECTION TYPE:C BULK CARGO COMPT STA 1461 RBL 8" FLOOR PANEL SUPPORT STIFFENER FOUND DEFORMED. FLOOR PANEL SUPPORT STIFFENER REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02, REV 46.SDR IPXA10658348Stiffener · deformedINSPECTION TYPE:C, BULK CARGO COMPT STA 1481 RBL 8" FLOOR PANEL SUPPORT VERTICAL STIFFENER FOUND DEFORMED. BULK CARGO COMPT STA1481 RBL8" FLOOR PANEL SUPPORT VERTICAL STIFFENER REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02, REV 46.SDR IPXA10658347Floor Support · crackedINSPECTION TYPE:C, BULK CARGO COMPT STA 1415 LBL 8" FLOOR PANEL SUPPORT (DEPRESSOR) LOWER RIVET AREA FOUND CRACK. FLOOR PANEL SUPPORT REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02, REV 46.SDR IPXA10658338Floor Support · crackedINSPECTION TYPE:C, AFT CARGO COMPT STA 1087 LBL 25" FLOOR PANEL SUPPORT CLIP FOUND CRACKED. AFT CARGO COMPT STA 1087 LBL 25" FLOOR PANEL SUPPORT CLIP. REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02 REV 46.SDR IPXA10658337Floor Support · crackedINSPECTION TYPE:C, AFT CARGO COMPT STA1087 RBL25" FLOOR PANEL SUPPORT CLIP FOUND CRACK. AFT CARGO COMPT STA1087 RBL25" FLOOR PANEL SUPPORT CLIP REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02.SDR IPXA10658361Skin · misrepairedINSPECTION TYPE:C, SURVEY SEQUENCE NR 327-F1-02 AFT CARGO DOOR AT BETWEEN STA 1246 TO 1263 AT STR 29R-32R. EXISTING REPAIR DOES NOT CORRELATE TO A SRM AFT CARGO DOOR OUTER SKIN REPAIRED IAW RS R52-00-36597 & UPS EO B767-5230-36491-A JUST AT STA1246-1263 BSDR IPXA10658389Spar · crackedINSPECTION TYPE:6C, LT WING - L/E LES 155 FIXED FAIRING UPPER SUPPORT WEB FRONT SPAR ANGLE FOUND CRACKED IN LENGTH 3/4" LT WING - L/E LES 155 FIXED FAIRING UPPER SUPPORT WEB FRONT SPAR ANGLE REPLACED AND INSTALLED IAW SRM 57-10-02 AND 51-40-02 REV 46.SDR IPXA10658362Floor Support · crackedINSPECTION TYPE:C, MEC CABIN FLOOR SUPPORT STA 246 CLIP RBL 10" FOUND CRACKED. MEC CABIN FLOOR SUPPORT AT STA246 RBL10" CLIP REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02 REV 46.SDR IPXA10658340Hinge Fitting · crackedINSPECTION TYPE:C, RT WING INBD MAIN FLAP INBD HINGE FTG FOUND CRACKED. RT WING INBD MAIN FLAP INBD HINGE FTG AT IFS179.75. REPAIRED IAW SRM 57-53-02-2R1 FIG201, REV46 BOTH FLANGES CRACK LENGTH AT INBD IS 0.75" & OTBD IS 1" ORG MATL IS 7075T3 FORGING BOTH INSDR IPXA10658339Hinge Fitting · crackedINSPECTION TYPE:C LT WING INBD MAIN FLAP INBD HINGE FTG FOUND CRACKED. LT WING INBD MAIN FLAP INBD HINGE FTG AT IFS179.75 REPAIRED IAW SRM 57-53-02-2R1 FIG201, REV46 BOTH FLANGES CRACK LENGTH AT INBD IS 1.2" & OTBD IS 0.375" ORG MATL IS 7075T73 FORGING. BOTH SDR IPXA10658336Skin · crackedINSPECTION TYPE:C, RT WING NR 10 SLAT L/E OTBD NOSE SKIN RIVET HOLE FOUND CRACKED AT OSS792.5. RT WING NR 10 SLAT L/E OTBD NOSE SKIN REPAIRED IAW SRM 57-43-01-2R2, FIG 201, REV46. JUST AT OSS792.5 ORIGINAL MATL IS CLAD7075T6-0063" CRACK LENGTH IS 0.09" DAMAGSDR IPXA10658335Skin · crackedINSPECTION TYPE:C, RT WING NR 10 SLAT L/E INBD NOSE SKIN RIVET FOUND CRACKED AT OSS723.9. RT WING NR 10 SLAT L/E INBD NOSE SKIN REPAIRED IAW SRM 57-43-01-2R2, FIG 201, REV46 JUST AT OSS723.9 ORIGINAL MATL IS CLAD7075T6-0063" CRK LENGTH IS 0.1" DAMAGED CUTOUSDR IPXA10658334Skin · crackedINSPECTION TYPE:C, RT WING NR 9 SLAT L/E OTBD NOSE SKIN RIVET HOLE FOUND CRACKED AT OSS641.9. RT WING NR 9 SLAT L/E OTBD NOSE SKIN REPAIRED IAW SRM 57-43-01-2R2, FIG 201, REV46 JUST AT OSS641.9. ORIGINAL MATL IS CLAD7075T6-0063" CRK LENGTH 0.15" DAMAGED CUTSDR IPXA10658333Skin · crackedINSPECTION TYPE:C, RT WING NR 9 SLAT L/E INBD NOSE SKIN RIVET HOLE FOUND CRACKED AT OSS572.5. RT WING NR 9 SLAT L/E INBD NOSE SKIN REPAIRED IAW SRM 57-43-01-2R2 FIG 201, REV46. JUST AT OSS572.5 ORIGINAL MATL IS CLAD7075T6-0063" CRK LENGTH IS 0.125" DAMAGED SDR IPXA10658332Skin · crackedINSPECTION TYPE:C, LT WING NR 4 SLAT L/E OTBD NOSE SKIN RIVET HOLE FOUND CRACKED AT OSS641.9. LT WING NR 4 SLAT L/E OTBD NOSE SKIN REPAIRED IAW SRM 57-43-01-2R2 FIG 201 REV46 JUST AT OSS641.9. CRACK LENGTH IS 0.125" DAMAGED CUTOUT SIZE IS 9" X 7.25" THIS RESDR IPXA10658331Skin · crackedINSPECTION TYPE:C, LT WING NR 4 SLAT L/E INBD NOSE SKIN RIVET HOLE FOUND CRACKED AT OSS572.5. LT WING NR 4 SLAT L/E INBD NOSE SKIN REPAIRED IAW SRM 57-43-01-2R2, FIG 201, REV46 JUST AT OSS572.5 ORIGINAL MATL IS CLAD7075T6-0063" CRACK LENGTH IS 0.125" DAMAGEDSDR IPXA10658330Skin · crackedINSPECTION TYPE:C, LT WING NR 3 SLAT L/E OTBD NOSE SKIN RIVET HOLE FOUND CRACKED AT OSS792.5. LT WING NR 3 SLAT L/E OTBD NOSE SKIN REPAIRED IAW SRM 57-40-03-2R2 FIG201 REV46 ORIGINAL MATL IS CLAD7075T6-0063" CRK LENGTH IS 0.08" DAMAGED CUTOUT SIZE IS 8.875" SDR IPXA10658329Skin · crackedINSPECTION TYPE:C, LT WING NR 3 SLAT L/E INBD NOSE SKIN RIVET HOLE FOUND CRACKED AT OSS723.9 LT WING NR 3 SLAT L/E INBD NOSE SKIN REPAIRED IAW SRM 57-43-01-2R2 FIG 201, REV46 JUST AT OSS723.9, CRACK LENGTH IS 0.09" DAMAGED CUTOUT SIZE IS 8.875" X 7.25" THIS SDR IPXA10658326Stiffener · crackedMEC CABIN FLOOR SUPPORT STA 246 STIFFENER LBL 40" FOUND CRACKED. MEC CABIN FLR SUPT AT STA 246 LBL 40" STIFFENER REPAIRED IAW SRM 53-10-51-2R4 FIG 201 REV 46. ORG MATL IS BAC1490-2793-7075T62, CRACK LENGTH IS 1.5" THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR.SDR IPXA10658301Angle · crackedINSPECTION TYPE:C MEC CABIN FLOOR SUPPORT STA246 ANGLE LBL25" FOUND CRACKED. MEC CABIN BS246 FLOOR SUPPORT AT LBL25" REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02 REV 46.SDR IPXA10658064Sensing Element · malfunctionedDIV - RT BLEED DUCT LEAK LIGHT, EICAS MESSAGE IN FLIGHT. R & R ELEMENT (TS216) IAW MM 26-18-01-4. ADJ/TEST IAW MM 26-18-01-5.SDR IPXA09656636Floor Panel · damagedINSPECTION TYPE:N/A FLOOR PANEL DAMAGED. REPAIRED FLOOR PANEL.SDR IPXA09656606Floor Panel · dentedINSPECTION TYPE:N/A D395815: MCD FLOOR PANEL AT POS 10 RT OF CTR HAS DENT 1.875 X 1 INCH AT NR 8 PALLET LOCK. FABRICATED FLOOR PANEL PER EO B767-5320-9693 APPX B.SDR IPXA09656596Floor Panel · damagedINSPECTION TYPE:N/A MC DECK FLOOR PANEL POS 1 O/B RIGHT AT STA 368 HAS 1.25 X .875 INCH HOLE. FABRICATED REPLACEMENT PANEL PER EO D767-5320-9693-F.SDR IPXA09656564Skin · dentedINSPECTION TYPE:N/A RIGHT O/B FLAP TWO AREAS OF DENTS ON UPPER AND LWR SURFACE. REPAIRED REF EO-B767-5750-32516-B.