N414UP
Service difficulty reports · 176
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N414UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N414UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA13577098Floor Panel · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 232XBF EDGES ARE DAMAGED. FABRICATED CABIN FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577097Floorboard · damagedINSPECTION TYPE:S3C8, FLOORBOARD 251XHF HAS A BROKEN CORNER AND SEVERAL CORRODED INSERTS. FABRICATED FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577096Floorboard · corrodedINSPECTION TYPE:S3C8, FLOORBOARD 251XAF HAS SEVERAL CORRODED INSERTS. FABRICATED FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577095Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 222XAF EDGES ARE DAMAGED. FABRICATED CABIN FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577094Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 232XUF EDGES ARE DAMAGED. FABRICATED CABIN FLOORBOARD 232XUF IAW SREO B757-5320-9692.SDR IPXA13577093Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 232XNF EDGES ARE DAMAGED. FABRICATED CABIN FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577092Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 221XCF EDGES ARE DAMAGED. FABRICATED CABIN FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577083Floorboard · damagedINSPECTION TYPE:S3C8, MAIN DECK FLOOR PANEL 251XNF HAS EDGE DAMAGE. FABRICATED MAIN DECK FLOOR PANEL IAW SREO B757-5320-9692.SDR IPXA13577082Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 231XSF EDGES ARE DAMAGED. FABRICATED CABIN FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577081Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 221XBF EDGES ARE DAMAGED (PANEL RACK) DOT NR 17-83. FABRICATED CABIN FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577080Floorboard · damagedINSPECTION TYPE: S3C8, MAIN DECK FLOORBOARD 252XSF HAS EDGE DAMAGE, NR 53-102. FABRICATED FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577079Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 231XRF EDGES ARE DAMAGED. FABRICATED CABIN FLOORBOARD IAW SREO NR B757-5320-9692.SDR IPXA13577078Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBORAD 231XAF EDGES ARE DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577077Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 231XBF EDGES ARE DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577076Floorboard · damagedINSPECTION TYPE: S3C8, FLOORBOARD 252XHF HAS 2EA CORRODED INSERTS. FABRICATED FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577074Floor Panel · damagedINSPECTION TYPE:S3C8, MAIN DECK FLOOR PANEL 242XEF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692.SDR IPXA13577073Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 231XVF EDGES ARE DAMAGED. FABRICATED NEW FLOORBOARD IAW SRM B757-5320-9692.SDR IPXA13577072Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 232XAF EDGES ARE DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577071Floorboard · damagedINSPECTION TYPE:S3C8, MAIN DECK FLOORBOARD 252XQF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13577069Floorboard · damagedINSPECTION TYPE:S3C8 CABIN FLOORBOARD 231XDF EDGES ARE DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA1567083Rotary Actuator · inoperativeON APPROACH, EXTENDING FLAPS HANDLE TO 1 DEGREE INDICTOR STOPPED BETWEEN UP AND 1 EICAS MSG L/E FLAP DISAGREE. RAN CHECKLIST, LAND W/FLAPS 20. DECLARED EMERGENCY T/S WRT FIM 27-81-00-815-803, FIG 104, REF L/P 622036 ITEM 2 L/P 622037 ITEM 2 L/P 622038 ITEM 1SDR IPXA11566987Control Unit · inoperativeEMERGENCY DECLARED - L/E SLAT SYS EICAS MESSAGE L/E SLAT DISAGREE DISPLAYED WITH FLAP LEVER IN 1. BOTH FLAP POINTERS INDICATED 1/2 LOWERED FLAPS WITH ALTERNATE FLAP SECURED. TROUBLESHOT IAW FIM 27-81-00, BLOCK 1 & 26. FOUND FS CK NR 2 FAULT. R & R FSCU IAWSDR IPXA1565036Strap · corrodedINSPECTION TYPE:C2, FOUND APU INLET DOOR HOUSING CUTOUT AFT STRAP CORRODED. FABRICATED AND REPLACED STRAP IAW ER 11-01645.SDR IPXA11564918Structure · chafedINSP TYPE:C2, NR 8 SLAT LWR T/E IS CHAFED 34-36" OTBD FROM INBD END. CHAFED, OUT-OF-LIMITS, REMOVED DAMAGED SKIN AND CORE, INSTALLED FABRICATED CORE AND DOUBLER IAW SRM 51-70-10-2R AND SRM 57-43-02-1A-1.SDR IPXA11564917Structure · chafedINSP TYPE:C2, NR 8 SLAT LWR T/E IS CHAFED 27-33", INBD FROM OTBD END CHAFED OUT-OF-LIMITS, REMOVED DAMAGED SKIN AND CORE, INSTALLED FABRICATED DOUBLER IAW SRM 51-70-10-2R AND SRM 57-43-02-0I-1.SDR IPXA11564921Wedge · chafedINSPECTION TYPE:2C14, NR 3 SLAT LOWER SURFACE OF THE T/E WEDGE HAS "OUT OF LIMITS" CHAFING DAMAGE 21" TO 34" INBD OF THE OTBD END. REMOVED DAMAGE AND REPAIRED WITH HOT BOND IAW SRM 51-70-10.SDR IPXA1564785Plate · crackedINSPECTION TYPE:C2, RT WING T/E LOWER SURFACE HAS CRACKED WIGGLE PLATE AT RSS 328. R & R WITH NEW WIGGLE PLATE IAW SRM 51-40-02-0G.SDR IPXA1565095Carriage · gougedINSPECTION TYPE:C2, RT WING NR 7 FLAP TRACK CARRIAGE HAS GOUGE ON OTBD FWD SIDE. REPAIRED CARRIAGE IAW ER 11-01629 AND EO B757-5750-41700-A DATED 03-03-2011.SDR IPXA1565077Skin · chafedINSPECTION TYPE:C2, LT WING OTBD MAIN FLAP, L/E UPPER SURFACE IS CHAFED E" FROM OTBD END. REPAIRED IAW ER 11-01651, EO B757-5750-416.88-A, SRM 51-70-10.SDR IPXA1564945Support Angle · corrodedINSPECTION TYPE:C2, WHILE WORKING CUSTOMER CARD NR 925136, FOUND APU INLET DOOR HSG SUPPORT ANGLE CORRODED, BS 1794-BS 1822, STR 6R. REPLACED ANGLE BS 1794-1822, STR 6R IAW SRM 53-00-04-1A1, SRM 51-40-02-0G, DWG 148N3152, SRM 51-30-01-0G, SRM 51-40-05-0G, SRMSDR IPXA1564944Support Angle · corrodedINSPECTION TYPE:C2, WHILE WORKING CUSTOMER CARD NR 925136, FOUND APU INLET HOUSING SUPPORT CLIP CORRODED, BS 1790-BS 1794, STR 6. REPLACED ANGLE SUPPORT (CLIP) BS 1790-BS 1794, STR 6 IAW SRM 51-10-02-0G, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-20-01-0G, SRM SDR IPXA1564943Support Angle · corrodedINSPECTION TYPE:C2, WHILE WORKING CUSTOMER CARD NR 925136, FOUND APU INLET DOOR HOUSING SUPPORT ANGLE CORRODED BS 1794-BS 1822, STR 3R. R & R INLET DOOR HSG SUPPORT ANGLE BS 1794- BS 1822, STR 3R IAW SRM 51-20-01, SRM 51-40-02-0G, M/M 51-21-00-7, SRM 53-00-04SDR IPXA11564908Floorbeam · puncturedINSPECTION TYPE:C2, FLOOR SUPPORT UPPER PLATE IS PUNCTURED, BS 900, WL 208, LBL 3 TO LBL 20. SUPPORT UPPER PLATE HAS NO LIMITS REPAIRABLE BY REPLACEMENT; REMOVED PUNCTURED; FABRICATED REPLACEMENT AND INSTALLED IAW SRM 51-10-02-0G, SRM 51-40-05-0G, SRM 51-40-SDR IPXA1565051Skin Panel · dentedINSPECTION TYPE:C2, FUSELAGE EXTERNAL SKIN DENT, BS 1604, JUST BELOW STR 4R LAP REPAIR IAW EO B757-5330-41593-A, DATED 03-01-2011 AND ER 11-01603, DATED 28-FEB-11.SDR IPXA1564966Strap · corrodedINSPECTION TYPE:C2, APU INLET DOOR HOUSING CUTOUT, FWD ATTACH STRAP HAS CORROSION AT SEVERAL NUTPLATE HOLES. FOUND DAMAGE TO BE OUT OF LIMITS IAW SRM 53-00-01-1A, REMOVED STRAP, FABRICATED REPLACEMENT STRAP IAW SRM 51-40-03-0G, SRM 51-40-06-0G, SRM 51-40-08-0SDR IPXA1564952Skin · dentedINSPECTION TYPE:C2, FUSELAGE EXTERNAL SKIN DENT, BS 1595, JUST BELOW STR 4R, LAP. DENT TO BE REPAIRED ON CARD NR925118 IN CONJUCTION WITH AND ADJACENT DENT.SDR IPXA11564920Skin · chafedINSPECTION TYPE:2C14, NR 3 SLAT EXTERNAL LOWER SKIN T/E CHAFED AT SEVERAL AREAS. REMOVED DAMAGE 2.7" X .7" AND HOT BOND REPAIRED IAW SRM 51-70-10.SDR IPXA1564813Floor Panel · delaminatedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS DELAMINATED ON UPPER SURFACE BS 1016-1055, LBL 25-45. FABRICATED REPLACEMENT FLOOR PANEL IAW EO 757-5320-9692-G.SDR IPXA1564812Floor Panel · delaminatedINSPECTION TYPE:C2, FLOOR PANEL NR 242XDF AFT EDGE DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1564811Floor Panel · delaminatedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS DELAM ON UPPER SURFACE BS 1020-BS 1055, LBL 45-60. FABRICATED REPLACEMENT PANEL IAW EO 757-5320-9692-G.SDR IPXA1565044Door Frame · wornINSPECTION TYPE:C2, RT APU DOOR NR 316AR FWD INNER FLANGE WORN AT OTBD EDGE. R & R FRAME IAW SRM 51-40-05-0G, SRM 51-20-01-0G AND AMM 51-20-00-0.SDR IPXA1564965Handle · gougedINSPECTION TYPE:C2, FWD CARGO DOOR EXTERNAL HANDLE, INNER SURFACE GOUGED AT SEVERAL PLACES, 3" FROM AFT END, MARKED. BLENDED GOUGED AREA ON LOWER LIP OF CARGO DOOR EXTERNAL HANDLE INTERNAL SURFACE 2"X .7" X .020" IAW EO NR B757-5230-36432-UPS, FIG 1. FOUND RSDR IPXA09555021Skin · dentedINSPECTION TYPE:C1 EMPENNAGE, FILLER MISSING IS DENT AT B 1957.2 RT, UPPER SURFACE (REQUIRES REPAIR PER SRM, AS DOCUMENTED ON CARD 796286). WORK PERFORMED IAW SRM 51-70-10-2R AND ER 09-1932.SDR IPXA09555027Skin · dentedINSPECTION TYPE:C1 DENT IN FUSELAGE BELLY SKIN BS 217 RBL 17. REPAIRED DENTED AREA IAW ER 09-1803 AND SRM 53-00-01-1A-1.SDR IPXA09555019Skin · wornINSPECTION TYPE:C1 LT WING NR 2 SLAT HAS WEAR ON T/E WEDGE LOWER SURFACE 14 INCHES FROM O/B END AT T/E. ALL WORK ACCOMPLISHED PER SRM 51-70-10-2R, RECEIVED APPROVAL FOR RCD SECT 2, AND ER 09-1919.SDR IPXA09555007Skin · dentedINSPECTION TYPE:C1 DENT IN FUSELAGE BELLY SKIN BS 217 RBL 17. REPAIRED DENTED AREA IAW ER 09-1803 AND SRM 53-00-01-1A-1.SDR IPXA09555032Skin · dentedINSPECTION TYPE:C1 DENT IN SKIN BS 1602, STR 4R. REPAIRED PER EA 09-1807.SDR IPXA09555031Skin · dentedINSPECTION TYPE:C1 DENT IN FUSELAGE SKIN BS 1593, STR 4R. REPAIRED PER EA 09-1807.SDR IPXA09555008Angle · crackedINSPECTION TYPE:C1 L-ANGLE CRACKED ON OUTBOARD SIDE OF THE NR 2 ENGINE PYLON, NAS 246, COMMON TO THE AFT LOWER CORNER OF PANEL 445AR CUTOUT. REMOVED AND REPLACED ANGLE IAW SRM 51-40-02-06 AND SRM 51-40-05-0G.SDR IPXA09554979Angle · crackedINSPECTION TYPE:C1 L-ANGLE CRACKED RT SIDE NR 2 PYLON NAS 209. REMOVED AND REPLACED ANGLE PER SRM 51-40-02.
Back to N414UP