N439UP
Service difficulty reports · 150
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N439UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N439UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2025120163604Valve · inoperativeABOUT 1000 LBS OF FUEL MIGRATED FROM R TO LEFT TANK OVER THE COURSE OF A 57 MIN FLIGHT. REMOVED AND REPLACED ENIGNE FUEL CROSSFEED VALVE BODYS (2 EA.) IAW AMM 28-22-02-004-042 AND 28-22-02-404-043. REMOVED AND REPLACED RT DEFUELING VALVE BODY IAW AMM 28-26-0SDR IPXA2025030374205Angle · corrodedFAULT: STR Z-300 APU INLET DOOR FWD LOWER CORNER ANGLE 148N3141-5 IS CORRODED. INSTALLED LOWER CORNER ANGLE PER SRM 51-40-02. REVIEWEDSDR IPXA2025021774058Strap · corrodedFAULT: STR Z-300 APU INLET DOOR FWD STRAP 148N3138-20 IS CORRODED. INSTALLED FWD STRAP IAW SRM 51-40-02 RIVET P/N BACR15CE8KE7 BACH#4256147. REVIEWEDSDR IPXA2025021674009Angle · corrodedAPU INLET DOOR UPPER ANGLE 148N3152-2 IS CORRODED. INSTALLED UPPER ANGLE IAW SRM 51-40-02.SDR IPXA2025021955007Skin · nickedUPPER FUS. EXTERNAL SKIN AROUND LH GPS ANTENNA STA 670 STR 1L-2L WITH NICKS (5 SPOTS)-DOT 139/14-MR/139.RESTORED SURFACE PROTECTION ON EXTERNAL SKIN AROUND LH GPS ANTENA STA 670 STR 1L-2L IAW SRM 51-20-01 AND AMM51-21-15.SDR IPXA2025020933681Strap · corrodedAPU INLET DOOR AT STA 1825 AFT STRAP HAS CORROSION.ACCOMPLISHED REPAIR PER 757-200PF SRM REV 122 CHAPTER 53-80-15-2R-1, DETAIL I ON FIGURE 202 (SHEET 2).SDR IPXA2025022192637Filler · corrodedNR 1 PYLON HAS SURFACE CORROSION AROUND FASTENER HOLES FOR PANEL 433CL. DOT 142-22.REMOVED CRACKED AND CORRODED STRAP (OUT OF LIMITS WITH EXFOLIATED CORROSION VISIBLE IAW SRM 51-10-08) IAW B757-200-51-40-02-OG.SDR IPXA2025021994372Frame · dentedDENT FOUND AT AFT CARGO COMPARTMENT FRAME STA 1540 R/H BETWEEN STR 22 AND STR 23.SURFACE HFEC PERFORMED ON CUT OUT ON AFT CARGO FRAME STA 1540 RH BETWEEN STR22-23. NO DEFECTS FOUND IAW NTM 51-00-19.SDR IPXA2025021195005Skin · corroded#2 ENGINE OUTBD PYLON INNER SKIN AFT OF THE MID SPAR FITTING HAS CORROSION. DOT 8-002. RESTORED SURFACE PROTECTION IN #2 ENG, OUTBD PYLON INNER SKIN IAW SRM 51-20-01 P/N ALODINE1132 BTCH 0004336881 PRIME P/N 02-013-8 BTCH 4263196.SDR IPXA2025021194979Skin · corrodedNR 2 ENGINE OUTBD PYLON INNER SKIN FWD OF VENT PANEL OPENING HAS SURFACE CORROSION AND PROTECTIVE COATING DETERIOATED. DOT 8-001. RESTORED SURFACE PROTECTION IN #2 ENG, OUTBD PYLON INNER SKIN IAW SRM 51-20-01 P/N ALODINE1132 BTCH 0004336881 PRIME P/N 02-013-8SDR IPXA2025021192630Skin · corrodedPYLON #1 INNER SURFACE, JUST FWD OF 433CL HAS AREA OF CORROSION. DOT IS ON OUTSIDE OF PYLON. DOT 142-15.SURFACE HFEC PERFORMED ON BLENDED AREA OF #1 PYLON INNER SURFACE JUST FWD OF 433CL PANEL. NO DEFECTS FOUND IAW NTM 51-00-19.SDR IPXA2025020870377Angle · corrodedAPU INLET DOOR STRUCTURE LOWER ANGLE PN: 148N3152-1 CORRODED.REMOVED AND REPLACED 1 EACH S-6R SUPPORT ANGLE (P/N: 148N3152-1) PER PRODUCTION DRAWING REQUIREMENTS AND 757-200PF SRM CHAPTER 51 REQUIREMENTS.SDR IPXA2025022643278Door · damaged**SUPPLEMENTAL SDR**FAULT: ZONE 800, STR, RH FUSELAGE, AFT CARGO DOOR CUTOUT, INNER/LOWER SIDE, HAS SEAL RETAINER DAMAGED. DOT 103-20.INSPECTED AND VERIFIED REMOVAL OF LOWER DOOR SILL AND DISPLACEMENT OF LOWER SEAL ON AFT CARGO DOOR.CLEANED AREA PER SOPM 20-30SDR IPXA2025022150787Plate · damagedNR 2 ENG, INB T/R INSIDE AREA HAS PLATE DAMAGED (ASSY LJ76605-0-01). DOT 34-007.REMOVED PLATE DAMAGE ON ENG# 2, INB T/R INSIDE AREA IAW SRM 51-40-02.INSTALLED NEW PLATE IN #2 ENG, T/R I/B, IAW SRM 51-40-02-0G-0 CHERRY MAX P/N CR3523-4-02 BTCH 0004348973 RTV106SDR IPXA2025022443278Retainer · damagedRH FUSELAGE, AFT CARGO DOOR CUTOUT, INNER/LOWER SIDE, HAS SEAL RETAINER DAMAGED.SDR IPXA2025022042790Fitting · gougedLH FUSELAGE, CREW DOOR FWD EDGE, LOWER AND UPPER ROD BEARING FITTINGS HAVE GOUGES. DOT 103-05. BLENDED OUT GAUGES AT LOWER AND UPPER LH CREW DOOR LATCH CAM IAW STEP 1 SREO-14721-REQ001. ACOMPLISHED WORK PER SREO-14721-REQ001.SDR IPXA2025021543109Plate · crackedRH FUSELAGE, FWD CARGO DOOR CUTOUT, LOWER SIDE, SILL PLATE HAS DENT WITH CRACK. DOT 103-10. INSTALLED SCUFF PLATE IAW AMM 53-13-02-4 PER SREO-36318-REQOO4 REV1.SDR IPXA2025020342790Fitting · gougedLH FUSELAGE, CREW DOOR FWD EDGE, LOWER AND UPPER ROD BEARING FITTINGS HAVE GOUGES.SDR IPXA2023022191207Seat Track · damagedINSPECTION TYPE:C15LBL 24.75 SEAT TRACK I/B FLANGE AT STA 1215 WITH 1 FASTENER HOLE OUT OF ROUND.REPAIRED IAW VT MAE# 757-5360-27-A3146SDR IPXA2023021791090Frame · dentedINSPECTION TYPE:C15*MAJOR REPAIR* FWD CARGO PIT FRAME 680 RH BETWEEN STR 23 TO STR 27 HAS AN EXISTING REPAIR WITH DENTREPAIRED PER UPS RCD 267664 - SRM 53-00-07-2R-5SDR IPXA2023022191217Frame · damagedINSPECTION TYPE:C15NEED ALTERNATIVE METHOD OF INSPECTION FOR EXISTING REPAIR AT STA 1320 BETWEEN 24R AND 27RREMOVED EXISTING REPAIR AND A NEW REPAIR IS ACCOMPLISHED PER VT MAE EA# 757-5360-27-A3138 REV- AND UPS RCD 267515SDR IPXA2023022291236Doubler · corrodedINSPECTION TYPE:SEG3#2 ENG PYLON I/B SKIN I/B SIDE BETWEEN PP STA 153.90 AND PP STA 163.10 HAS CORROSION.REPAIRED I/B AFT PYLON SKIN PER VT MAE EA# 757-5450-27-A3142 REV-.SDR IPXA2023022091165Frame · damagedINSPECTION TYPE:C15NEED ALTERNATIVE METHOD OF INSPECTION FOR EXISTING FRAME PAIR AT FS1520 BETWEEN STR 25 AND 27 RH SIDEREMOVED EXISTING REPAIR AND A NEW REPAIR IS ACCOMPLISHED PER VT MAE EA# 757-5360-27-A3137 REV - AND UPS RCD 267516SDR IPXA2022052382400Door · indicationL FWD ENT DOOR EICAS MSG DISPLAYED AFTER LANDING @ 90 KTS. REMOVED AND REPLACED SENSOR SUPPORT BRACKET PER SRM 51-46-02. INSTALL / ADJUST SENSOR IAW AMM 52-71-00-805-223.SDR IPXA2021042768684Module · malfunctionedINSPECTION TYPE:NAEMERG LIGHTS "UNARMED" LIGHT STAYS ONR/R LIGHT SWITCH MODULE IAW AMM 33-51-08-404-011. ESR: IPC 31-12-11-13SDR IPXA2021022265929Skin · gougedINSPECTION TYPE: SEG 2 MAIN CARGO DOOR OUTER LOWER SKIN GOUGED. TEMP REPAIRED PER UPS EO B757-5230-79320-A VTMAE EA 757-5230-27-A2549 REV-.SDR IPXA2020062435891Switch · out of positionEMERGENCY DECLARED. NOTICED ON CLIMBOUT THRU ABOUT 10000 FT THAT VOM INDICATOR STUCK AT 265 KTS. EVENTUALLY STUCK AT 242 KNOTS (MACH 72) AT 35000 FT. VMO STUCK SAME ON BOTH CAPTAIN`S AND F/O`S DISPLAY. AIRSPEED MATCHED AND SEEMED ACCURATE ACROSS CAPT AND FSDR IPXA2020042954726Battery · dischargedINSPECTION TYPE:NAEMERGENCY EXIT LIGHT ABOVE CREW DOOR INOPT/S TO A FAULTY BATTERY. R&R'D THE SAME. OPS CKS GOOD. OK FOR SERVICE. REF 757 AMM 33-51-07-902-001SDR IPXA2019021539029Floor Panel · brokenINSPECTION TYPE:SEG1MAIN CARGO FLOOR PANEL 232XEF IAS BROKENFABRICATED NEW FLOOR PANEL 232XEF FROM 5024N40000155-G BATCH 33550636 IAW SREO B757-5230-9692KSDR IPXA2017022814546Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 242XGF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017022814545Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 241XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017022814544Floor Panel · puncturedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 242XKF IS PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017022814543Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 242XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017022814542Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 241XMF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017022814541Floor Panel · damagedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 241XKF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692J.SDR IPXA2017030114605Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 231XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017030114604Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 231XJF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J, FABRICATED FIBERGLASS OVERLAYS IAW SREO B757-5320-9692-J. APPLIED FIBERGLASS OVERLAYS AND SANDED IAW SREO B757-5320-9692-J.SDR IPXA2016031000571Escape Rope · detachedF/O ESCAPE ROPE COVER FELL OFF AND CANNOT BE REATTACHED. REPLACED F/O'S FLT COMPARTMENT ESCAPE ROPE STORAGE DOOR ASSY WRT AMM 25-61-00-424-005 GROUND CHECKS GOOD, IPC REF 25-14-01-02, ITEM 705.SDR IPXA2016011297707Escape Reel · inoperativeEMERGENCY DECENT ESCAPE DEVICE INOPERATIVE, REEL / INERTIAL, REF TC 25-061-101.SDR IPXA2015091193396Guard · brokenEMERGENCY LIGHTS GUARD SWITCH BROKEN. REPLACED SWITCH GUARD. OPS CHECKED NORMAL. IAW AMM 33-51-00.SDR IPXA2015040287656Skin · damagedINSPECTION TYPE:C, NR 1 PYLON INBD SKIN DAMAGE. REPAIRED NR 1 PYLON INBD SKIN, PN 311N5046-34 IAW EA 757-5451-27-A2172 AND EO B757-5430-57073-A.SDR IPXA2015032687433Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 252XUF HAS EDGE DAMAGE, PANEL RACK. FABRICATED IAW SREO B757-5320-9692-H APP B. REINFORCING DOUBLERS REQUIRED IAW SREO B757-5320-9692-H APPEN B. SCUFF SAND THE REPAIR AREA TO BE BONDED IAW EO B757-5320-9692-H AND SRMSDR IPXA2015032687432Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL NR 212XAF IS DELAMINATED, PANEL RACK. FABBED 212XAF, PN 141N5410-28 FROM A402H-48X144, BATTERY 2664589 AND ACCOMPLISHED STEP CUT IAW SREO B757-5320-9692-H APPEN B. REINFORCE STEP CUT IAW B757-5320-9692-H APPEN B. SCUSDR IPXA2015032387322Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XHF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387328Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XRF IS DELALMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387332Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XMF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387327Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XAF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387326Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XAF HAS EDGE DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387321Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032687435Floor Panel · delaminatedINSPECTION TYPE:C, MAINTENANCE REQUIRED, MAIN DECK CREW ENTRY FLOOR PANEL 211XAF IS DELAMINATED. PANEL RACK1, FABBED 211XAF FROM A402H-48X144, BATTERY 2664589 IAW SREO B757-5320-9692-H APPEN B. BOND REINFORCING PLIES IAW SREO B757-5320-9692-H APPEN B. SCUFF
Back to N439UP