N439UP
Service difficulty reports · 150
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N439UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N439UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2015032587407Seat Track · gougedINSPECTION TYPE:C, MAIN DECK SEAT TRACK, LBL 45-50 BS 1480-1520 HAS GOUGE, 1BLENDED GOUGES MAIN DECK SEAT TRACK, LBL 45.50 BET STA 1480-1520 IAW SRM 51-10-02-6. MAX ALLOWABLE DIAMETER OF SEAT TRACK SCALLOP=0.84 AFTER BLEND ACTUAL DIAMETER OF SCALLOP=0.98,L=0.SDR IPXA2015032587398Seat Track · gougedINSPECTION TYPE:C, MAIN DECK SEAT TRACK, RBL 24-75 BET STA 1580-1600 HAS GOUGED. BLENDED GOUGE MAIN DECK SEAT TRACK RBL 24.75 BET STA 1580-1600 IAW SRM 51-10-02-0G. MAX ALLOWABLE. DIAMETER OF SEAT TRACK SCALLOP=0.84 AFTER BLEND ACTUAL DIAMETER OF SCALLOP =0SDR IPXA2015032387334Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XFF HAS WATER DAMAGED. PANEL RACK 1, FABRICATED IAW SREO B757-5320-9692-H APPEND B. 1, 2. BOND REINFORING PLIES IAW SREO B757-5320-9692-H APPEN B 2. SCUFF SANDED AND PREP IT THE BONDING AREA IAW EO B757-5320-9692-SDR IPXA2015032387333Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XJF IS DELAMINATED. PANEL RACK 1. FABBED 231XJF FROM A402H-48X144, BATTERY 0664589 IAW SREO 5320-9692-H APPEN B1, 2. BOND REINFORCING PLIES IAW SREO B757-5320-9692-H APPEN B 2. SCUFF SANDED AND PREP OT THE BONDINGSDR IPXA2015032387324Floor Panel · crackedINSPECTION TYPE:CMAIN DECK FLOOR PANEL 221XBF IS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387331Floor Panel · crackedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 232XFF IS CRACKED. PANEL RACK, FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387325Floor Panel · brokenINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 252XCF IS BROKEN. PANEL RACK 1, FABBED PANEL 252XCF FROM A402H-48X144 BAT 2664589 IAW SREO B757-5320-9692-H.SDR IPXA2015032387320Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 251XFF IS DELAMINATED. PANEL RACK, FABRICATED PANEL 251XFF FROM A402H-48X144, BAT 2664589 IAW B757-5320-9692-H.SDR IPXA2015032387319Floor Panel · crackedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 251XGF IS CRACKED AND PUNCTURED. PANEL RACK, FABRICATED PANEL 251XGF FROM A403H-48X144, BATTERY 2664589 IAW SREO B757-5320-9692-H.SDR IPXA2014120885017Anti-Ice Valve · inoperativeRECEIVED AN EICAS MESSAGE WHEN THE ENGINE ANTI ICE WAS TURNED ON. RETURNED TO DEPARTURE. R & R RT ENGINE TAI VALVE IAW AMM 30-21-03-004-017 & 30-21-03-404-014. OPS CHECKED GOOD IAW 30-21-00-735-001.SDR IPXA2014041682683Bulb · inoperativeEMERGENCY LIGHT ASSY HAS FOUR BULBS INOPERATIVE. REPLACED BULBS IAW AMM 33-51-01-2.SDR IPXA3577745Floorboard · damagedINSPECTION TYPE: C1S2, CABIN FLOORBOARD 241XFF DAMAGED AT EDGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577744Floor Panel · damagedINSPECTION TYPE: C1S2, MAIN DECK FLOOR PANEL 241XDF EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-HSDR IPXA3577743Floor Panel · damagedINSPECTION TYPE:C1S2, MAIN DECK FLOOR PANEL 241XAF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692H.SDR IPXA3577742Floor Panel · damagedINSPECTION TYPE:C1S2, MAIN DECK FLOOR PANEL 242XJF UPPER SURFACE DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-96 92-H.SDR IPXA3577741Floor Panel · damagedINSPECTION TYPE:C1S2, MAIN DECK FLOOR PANEL 242XHF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B727-53 20-9692-H.SDR IPXA3577739Floor Panel · puncturedINSPECTION TYPE:C1S2, MAIN DECK FLOOR PANEL 242XGF LOWER SURFACE PUNCTURED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3577738Floor Panel · damagedINSPECTION TYPE:C1S2, MAIN DECK FLOOR PANEL 242XFF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-532 0-9692-H.SDR IPXA3577737Floor Panel · crackedINSPECTION TYPE:C1S2, MAIN DECK FLOOR PANEL 242XCF CRACKED. FABRICATED NEW FLOOR PANEL IAW EO B757-532 0-9692-H.SDR IPXA3577736Floor Panel · damagedINSPECTION TYPE:C1S2, MAIN DECK FLOOR PANEL 241XCF HAS A DAMAGED INSERT. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3577859Slat · dentedINSPECTION TYPE:C1S2, LT WING NR 4 SLAT HAS A DENT WITH A CREASE IN THE BOTTOM. REPAIRED SLAT IAW EO B757-5750-50448A AND FINAL EA 757-5712-27-A2084.SDR IPXA3577858Skin · dentedINSPECTION TYPE:C1S2, LT WING NR 5 SLAT OUT SKIN HAS A DENT WITH CREASE IN THE BOTTOM OF IT DOT 13/013. REPAIRED PANEL IAW SRM 51-70-10-2R, REPAIR & REPAIR 2 57-43-02-2R REPAIR 1.SDR IPXA3577625Bulb · burned outEMERGENCY LIGHT ASSY HAS SIX INOPERATIVE BULBS. REPLACED BULBS IAW AMM 51-01-2.SDR IPXA13577007Transmission · inoperativeEMERGENCY DECLARED, FLAPS FAILED TO MOVE, T/E LIGHT ON AND EICAS MESSAGES T/E FLAP DISAGREE DISPLAYED FLAPS ALSO INOPERATIVE ON T/E ALTERNATE SYS. ACCOMPLISHED FIM 27-51-00-815-805 AND FIM 27-51-00-815-808 FOUND NR 4 FL FLAP TRANSMISSION OVERLOAD INDICATOR TSDR IPXA1569965Wire Harness · shortedRT AMBER THRUST REVERSER LIGHT ILLUMINATED AFTER LEVELING OFF. RETURNED TO BDL AS PRECAUTIONARY. DEFERRED. ASSIGNED M464790. TROUBLE SHOT WITH WDG 78-51-22 & 21-51-22. FOUND SHORTED WIRES ON UNSERVICEABLE CLAMP. REPLACED 2 HARNESSES. OPS CHECK REVERSER IASDR IPXA1569647Sliding Window · bindingCAPT SLIDING WINDOW LOCKING HANDLE BINDING IN BOTH DIRECTIONS. ADJUSTED LT (CAPT) SLIDING WINDOW IAW AMM 56-11-02-5. 2 WINDOW ADJUSTMENT/TEST SATISFACTORY IAW AMM.SDR IPXA11566553Floor Panel · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOOR PANEL 232BF HAS INSERTS PULLED OUT AND EDGE DAMAGE. FABRICATED NEW MAIN CARGO COMPARTMENT FLOOR PANEL.SDR IPXA11566068Floorboard · crushedINSP TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD PANEL 231XDF CRUSHED ON OTBD SIDE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA11566067Floor Panel · crackedINSPECTION TYPE:C4, MAIN CARGO FLOOR PANEL 232XGF HAS CRACKED EDGE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA11566032Floorboard · crackedINSPECTION TYPE:CK, FLOORBOARD PANEL 231XEF CRACKED ON OTBD EDGE. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11566020Floorboard · damagedINSPECTION TYPE:CK, MAIN CARGO COMPARTMENT FLOORBOARD 231XQF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566019Floorboard · damagedINSPECTION TYPE:CK, MAIN CARGO COMPARTMENT FLOORBOARD 241XLF IS DAMAGED. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11566010Floor Panel · brokenINSPECTION TYPE:C4, FLOOR PANEL 252XQF STA 1540-1600, 1 EA INSERT BROKEN OUT. FABRICATED NEW PANEL IAW EO B757-5320-9692-G.SDR IPXA11566113Frame · dentedINSPECTION TYPE:CK, FWD CARGO COMP STA 800 BETWEEN STR 23 AND 24L FRAME IS DENTED. REMOVED DAMAGE AND REPAIRED IAW SRM 53-00-07-2R5.SDR IPXA11566099Frame · dentedINSPECTION TYPE:C4, FWD CARGO COMPARTMENT STA 780 BETWEEN STR 24R AND 23R FRAME IS DENTED. REMOVED DAMAGE, CUTOUT AREA, HFEC FASTENER HOLES, FABRICATED REP AIR "J" SECTION FROM 7075-0, HEAT TREATED PART TO T6 CONDITION, MADE INSURANCE CUT AT CUT OUT AREA. TRSDR IPXA11566066Frame · dentedINSPECTION TYPE:C4, FWD CARGO COMPARTMENT STA 720 BETWEEN STR 23L AND 24L FRAME IS DENTED. CUT OUT DAMAGED AREA AND FABRICATED REPAIR DOUBLER, HEAT TREATED, TRIM MED BACK DRILLED, PRIMED AND INSTALLED REPAIR DOUBLER, AND APPLIED CIC TO AREA IAW SRM 53-00-07-2SDR IPXA11566065Frame · dentedINSPECTION TYPE:C4, FWD CARGO COMPARTMENT STA 700 BETWEEN STR 23R AND 24R FRAME IS DENTED. REMOVED DAMAGE, FABRICATED REPAIR ANGLE, DRILLED STACK UP THROUGOUT, HEAT TREATED ALODINED, PRIMED, COLD WORKED, INSTALLED, PART MARKED, AND CIC'D IAW SRM 53-00-07-2R5.SDR IPXA11566064Frame · dentedINSPECTION TYPE:C4, FWD CARAGO COMPARTMENT STA 700 BETWEEN STR 23R AND 24R FRAME IS DENTED. REMOVED DAMAGE, FABRICATED REPAIR ANGLE, DRILLED STACK UP THROUGOUT, HEAT TREATED ALODINED, PRIMED, COLD WORKED, INSTALLED, PART MARKED, AND CIC'D IAW SRM 53-00-07-2R5SDR IPXA11566062Frame · dentedINSPECTION TYPE:C4, FWD CARGO COMP STA 800 BETWEEN STR 23R AND 24R FRAME IS DENTED. CUTOUT DAMAGE, FABRICATED REPAIR ANGLE FROM 7075-0-.071. HEAT TREATED TO T6 CONDITION TREATED, PRIMED AND INSTALLED REPAIR PART IAW SRM 53-0 0-07-2R5 DETAIL 1 FRAME ORIGINAL SDR IPXA1565855Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO FLOOR PANEL 232XSF AFT CORNER DAMAGED. REPLACED FLOOR PANEL WHICH WAS FABRICATED IAW EO B757-5320-2692-G.SDR IPXA11566100Floorbeam · corrodedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT STA 440, RBL 44, WL 208 FLOORBEAM HAS CORROSION AT FASTENER. SPLICED IN NEW SECTION OF SEAT TRACK IAW SRM 53-00-52-2R-5.SDR IPXA1565871Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD 232XFF RT HAS SEVERAL BAD INSERTS DELAMINATED AND ERODED. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA11566011Seat Track · corrodedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT STA 1667, LBL 45.5, SEAT TRACK FLANGE HAS CORROSION AT FLOORBOARD HOLE. FABRICATED AND INSTALLED SEAT TRACK SECTION IAW SRM 53-00-52-2R, REPAIR.SDR IPXA11566018Floor Panel · crushedINSP TYPE:CK, MAIN CARGO DECK PANEL 231XMF IS CRUSHED ALONG EDGE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA11566008Floor Panel · crackedINSP TYPE:C4, MAIN CARGO DECK PANEL 252XLF IS CRACKED AT AFT SECTION. FABRICATED NEW PANEL IAW EO B757-5320-9692-G.SDR IPXA11566007Floorboard · damagedINSPECTION TYPE:C4 MAIN CARGO AREA: PNL 242XAF FWD RT AND LT CORNERS ARE DAMAGED. REPLACED PANEL IAW EO B757-5320-9692-G.SDR IPXA1565893Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO DECK FLOOR PANEL 251XQF HAS 2 MISSING INSERTS. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1565892Floor Panel · delaminatedINSPECTION TYPE:C4, MAIN CARGO DECK FLOOR PANEL 252XTF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-GSDR IPXA1565891Floor Panel · delaminatedINSPECTION TYPE:C4 MAIN CARGO DECK FLOOR PANEL 231XCF IS DELAMINATED IN THE CORNER FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-GSDR IPXA1565890Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO FLOOR PANEL 242XDF CORNER IS DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.