N442UP
Service difficulty reports · 145
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N442UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N442UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2015042188259Floorbeam · corrodedINSPECTION TYPE:C, MAIN CARGO DECK FLOORBEAM, BS 620, LBL 33 HAS CORROSION. ACCOMPLISHED FLOORBEAM REPAIR AT STA 620, LBL 33 IAW 757-200PF SRM 53-00-51-28, REPAIR 6, DETAIL III.SDR IPXA2015041588120Floor Panel · delaminatedINSPECTION TYPE:C, MECHANIC REQUEST: CABIN FLOOR PANEL 222XCF DELAMINATED. TRANSFERRED FROM 2015041588116, FABRICATED NEW FLOOR PANEL 222XCF IAW SAMPLE IAW EO 5320-9692-H MATERIAL A402H-48X144 BATCH NR 2664589.SDR IPXA2015041688147Floor Panel · damagedINSPECTION TYPE:CMCD, FREIGHTER FLOOR PANEL 232XCF HAS EDGE DAMAGED FABRICATED NEW FLOOR PANEL 232XCF IAW SAMPLE IAW EO-B757-5320-9692-H. MATERIAL A402H-48X144, BATCH 2664589.SDR IPXA2015041087955Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 251 XJF EDGES HAS PUNCTURES FABRICATED NEW FLOOR PANEL 251 XJF IAW SAMPLE IAW EO B757-5320-9692-H.SDR IPXA2015041087951Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 251 XKF HAS DELAMINATION FABRICATED NEW FLOOR PANEL 251 XKF IAW SAMPLE IAW EO B757-5320-9692-H, MATERIAL A402H-48 X 144 BATCH 2664589.SDR IPXA2015041087950Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 251 X FF EDGES HAS SEVERAL PUNCTURES. FABRICATED NEW FLOOR PANEL 251 X FF IAW SAMPLE IAW EO B757-5320-9692-H MATERIAL A402H X 48 X 144 BATCH 2664589.SDR IPXA2015040987919Shear Web · corrodedINSPECTION TYPE:C, MAIN CARGO DECK FLOOR SHEAR WEB AT RBL 35 BET STA 345 AND 365 HAS CORROSION. REMOVED FASTENERS 07 EA FOR ACCESS IAW SRM 51-40-02-0G. REMOVED CORROSION AREA IAW SRM 51-10-02-06, ORIGINAL MATERIAL .100 MAT LOSS .012 REMAINING MATERIAL .088 FSDR IPXA2015040987911Shear Web · corrodedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR SHEAR WEB AT RBL 35 BETWEEN STA 345 AND STA 365 HAS CORROSION, DOT 82-0351, REMOVED FASTENERS ,07 EA, FOR ACCESS IAW SRM 51-40-02-06. REMOVED CORROSION AREA IAW SRM 51-10-02-06 ORIGNAL MATERIAL .100, MATERIAL .2055SDR IPXA2015041087953Floor Panel · puncturedINSPECTION TYPE:C, CABIN FLOOR PANEL 241 XBF IS PUNCTURED WITH SCREW STUCK UNDER SIDE EDGE FABRICATED NEW FLOOR PANEL 241 XBF IAW SAMPLE IAW EO B757-5320-9692-H.SDR IPXA2015041087956Floor Panel · delaminatedINSPECTION TYPE:C, CABIN FLOOR PANEL 231 XWF IS DELAMINATED/EDGES BROKEN OFF. FABRICATED NEW FLOOR PANEL 231 XWF IAW SAMPLE IAW EO B757-5320-9692-H, MATERIAL A402H-48 X 144 BATCH 2664589.SDR IPXA3578074Skin · dentedINSPECTION TYPE:C-10 LT WING OTBD T/E FLAP INBD END UPPER SURFACE OF AFT FLAP HAS A DENT. FABRICATED AND INSTALLED REPAIR IAW SRM 57-53-01-2R1, 51-70-04 P5B, AND 51-70-17 FIG 24.SDR IPXA13577821Floor Panel · delaminatedINSPECTION TYPE:C-10, MAIN CABIN FLOOR PANEL NR 241-XHF HAS DELAMINATION. FABRICATED A NEW FLOOR PANEL IAW REO B757-5320-9692-H.SDR IPXA13577820Floor Panel · delaminatedINSPECTION TYPE:C-10, MAIN CABIN FLOOR PANEL 241XAF HAS DELAMINATION. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577819Floor Panel · crushedINSPECTION TYPE:C-10, MAIN CABIN DECK FLOOR PANEL 242XHF HAS A CRUSHED CORNER. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577818Floor Panel · crushedINSPECTION TYPE:C-10, MAIN CABIN FLOOR PANEL NR 241-XEF HAS A CRUSHED CORNER. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA1570256Cover · malfunctionedEMERGENCY LIGHT SWITCH COVER, WHEN CLOSED, TURNS EMERGENCY LIGHTS TO OFF - VICE ARMED. REPLACED EMERGENCY LIGHT SWITCH IN REF TO MM 33-50-00. OPS CHECKED GOOD.SDR IPXA1568968Bulb · inoperativeCREW REPORTED THE EMERGENCY LIGHTS "UNARMED " ANNUNCIATION LIGHT WAS INOPERATIVE. RELAMPED UNARM LIGHT. OPS CHECKED EMERGENCY UNARM LIGHT IAW AMM 33-51- 00-5.SDR IPXA11567317Frame · wornINSPECTION TYPE:C, CK MAIN CARGO FRAME AT BS 1540 INBD FLANGE HAS WEAR BETWEEN STR 15-16R. REPAIRED FRAME DAMAGE IAW EA 110577.SDR IPXA11567316Floor Panel · damagedINSPECTION TYPE:C, CK MAIN CABIN FLOOR PANEL NR231 XAF, FABRICATED NEW FLOOR BOARD IAW EO 757-5320-9692-G ON WO 21617/1000-0007.SDR IPXA11567282Floor Panel · damagedINSPECTION TYPE:C, CHECK FLOOR PANEL 231XBF AT BS 440 HAS CORE DAMAGE AT FWD EDGE. FABRICATED NEW FLOOR PANEL 231 XBF IAW SAMPLE AND EO B757-5320-9692-G ON WO 21617/1000-0006.SDR IPXA11567187Frame · dentedINSPECTION TYPE:S1C9, AFT CARGO COMPARTMENT STA 1400 FRAME DENTED BETWEEN STR 23L AND 24L. REPAIRED FRAME IAW SRM 53-00-07-2R 5 AND REPLACED STRINGER CLIP AT STR 23L IAW EA 110564.SDR IPXA11567166Floor Panel · crushedINSPECTION TYPE:S1C9, FLOOR PANEL 2562XLF UPPER SURFACE HAS CRUSH DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL.SDR IPXA11567165Floor Support · corrodedINSPECTION TYPE:S1C9, MAIN CARGO COMPARTMENT STA 1640, RBL 46.5 UPPER FLOOR TRACK CORRODED AT FASTENER AS MARKED. REPAIRED SEAT TRACK IAW SRM 53-00-52-2R5.SDR IPXA11567576Frame · dentedINSPECTION TYPE:C, AFT PIT BS 1320 FRAME IN DENTED ON INNER FLANGE AT STR 25L. REMOVED DAMAGE AND REPAIRED FRAME SECTION IAW SRM 53-00-07-2R, REPAIR 5, DET 3.SDR IPXA1567345Frame · dentedINSPECTION TYPE:C-CK LOWER FRAME DENTED AT BS 1260 BETWEEN STRINGERS 24R AND 24L IN MULTIPLE AREAS. FABRICATED AND REPLACED FRAME.SDR IPXA11567183Floor Panel · damagedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 252XFF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567182Floor Panel · damagedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 232XHF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567181Floor Panel · damagedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 231XLF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567164Floor Panel · damagedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PNL251 XLF HAS EDGE DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567242Floor Panel · delaminatedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 231XEF HAS DELAMINATED DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567185Floor Panel · delaminatedINSPECTION TYPE:S1C9 MAIN CARGO FLOOR PANEL 232XFF HAS DELAMINATED DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567180Floor Panel · damagedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 232XXF EDGE DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567177Floor Panel · damagedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 241XCF IS BROKEN. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567176Floor Panel · delaminatedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 221XCF HAS MULTIPLE MISSING INSERTS AND DELAMINATIONS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567173Floor Panel · delaminatedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 251 XBF HAS MULTIPLE CORRODED INSERTS AND DELAMINATIONS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1567056Panel · damagedINSPECTION TYPE:S1C9, LAV PANEL NR 212XAF HAS CORE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1567053Frame · dentedINSPECTION TYPE:SAC9, AFT PIT, FUSELAGE FRAME UPPER FLANGE HAS A DENT, BS 1500, STR-23R. ACCOMPLISHED REPAIR IAW SRM 53-00-07-2R 5 REPAIR 5 EA 110550.SDR IPXA1567369Beam · corrodedINSPECTION TYPE:C1, FLOORBEAM AT STA 1040 +15" RBL 26-45 CORRODED. FABRICATED FLOORBEAM AND INSTALLED IAW SRM 5300-52-1A.SDR IPXA11567287Seat Track · damagedINSPECTION TYPE:C-CK FASTENER HOLE DAMAGE FOUND AFTER REMOVING DAMAGED SEAT TRACK STA 1540, RBL 44.5 FORWARD HOLE. REPAIRED FLOORBEAM STA 1540, RBL 44.5 MAIN CARGO COMPARTMENT IAW EA 110719.SDR IPXA11567284Seat Track · corrodedINSPECTION TYPE:C, CHECK CONTROL CABIN BETWEEN CAPTAIN AND F/O AFT INBD SEAT TRACK FLOOR IS CORRODED. REPAIRED CONTROL CABIN FLOOR BETWEEN CAPTAIN AND F/O AFT INBD SEAT TRACK IAW EA 110724.SDR IPXA11567283Seat Track · corrodedINSPECTION TYPE:C, CHECK, CONTROL CABIN OTBD OF PILOT AFT INBD SEAT TRACK FLOOR IS CORRODED. REPAIRED CONTROL CABIN FLOOR OTBD OF PILOT AFT INBD SEAT TRACK IAW EA 110724.SDR IPXA11567243Frame · gougedINSPECTION TYPE:S1C9, MAIN CARGO FRAME HAS GOUGE FROM FASTENER AT STA 880 BETWEEN S15L AND S 16L. REPAIRED MAIN CARGO FRAME STA 880 BETWEEN S15L AND S16L IAW EA 110718.SDR IPXA11567184Floor Panel · delaminatedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 251XPF HAS DELAMINATION ON INBD EDGE. FABRICATED NEW FLOOR PANEL 251XPF IAW SAMPLE AND EO B757-5320-9692-G.SDR IPXA11567179Floorboard · damagedINSPECTION TYPE:S1C9, MAIN CARGO FLOORBOARD 241XLF HAS DAMAGE ON INBD BOTTOM EDGE. FABRICATED NEW FLOORBOARD 241XLF IAW SAMPLE AND EO B757-5320-9692-G.SDR IPXA11567178Floor Panel · damagedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 232XNF DAMAGED. FABRICATED NEW FLOOR PANEL 232XNF IAW SAMPLE AND EO B757-5320-9692-G.SDR IPXA11567169Floor Panel · delaminatedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 251XMF IS DELAMINATED ON BOTTOM SEVERAL AREAS MARKED. FABRICATED NEW FLOOR PANEL 251XMF IAW SAMPLE AND EO B757-5320-9692-G.SDR IPXA11567167Floor Panel · damagedINSPECTION TYPE:S1C9, MAIN CARGO PANEL 251 XAF DAMAGED ON TOP AFT EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567163Floor Support · corrodedINSPECTION TYPE:S1C9, MAIN CARGO COMPARTMENT STA 1540, RBL 44.5 UPPER FLOOR TRACK CORRODED AT FASTENER. REPAIRED MAIN CARGO COMPARTMENT FLOOR TRACK STA 1540, RBL 44.5 IAW SRM 53-00-52-2R, REPAIR 5.SDR IPXA11567162Floor Panel · delaminatedINSPECTION TYPE:S1C9, FLOOR PANEL 252XUF AT BS 1720 HAS DELAMINATION DAMAGE. FABRICATED NEW FLOOR PANEL 242XUF IAW SAMPLE AND EO B757-5320-9692-G.SDR IPXA1567061Floor Panel · damagedINSPECTION TYPE:S1C9, MAIN CARGO FLOOR PANEL 232XMF DAMAGED. FABIRCATED NEW FLOOR PANEL IAW EO B757-5325-9692-G.