N465UP
Service difficulty reports · 208
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N465UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N465UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA13578185Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 231XNF HAS EDGES TORN, FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3578344Floorbeam · corrodedINSPECTION TYPE:C8S4, MCD FLOORBEAM UPPER TEE CAP AT FS 1200 CORRODED FROM LT CREASE BEAM TO RT CREASE BEAM. REMOVED CORROSION IAW SRM 51-10-02-0G.SDR IPXA3578291Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 232XWF HAS ALL EDGES TORN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578221Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 241XDF HAS ALL EDGES TORN AND TOP SIDE CRUSHED. FABRICATED NEW FLOORBOARD IAW EOB757-5320-9692-H.SDR IPXA13578218Floorboard · damagedINSPECTION TYPE: C8S4, FLOORBOARD 231XWF HAS ALL EDGES TORN AND DELAMINATED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-4 -H.SDR IPXA3578319Skin · puncturedINSPECTION TYPE:C8S4, RT INBD MAIN FLAP T/E WEDGE LOWER SKIN PUNCTURED. , REMOVED DAMAGE, FABRICATED REPLACEMENT CORE PLUG, FABRICATED REPAIR OVERLAYS, BONDED REPAIR MATERIALS. FINAL SAND, SEAL, PRIME AND PAINT REPAIR IAW SRM 51-70-07-0G.SDR IPXA3578316Skin · dentedINSPECTION TYPE:C8S4, RT WING NR 3 SLAT DENTED AND DELAMINATED IN CENTER. ACCOMPLISHED PERMANENT REPAIR IAW RCD 006386SDR IPXA3578342Skin · dentedSKIN DENT ON NR 1 ENGINE INBD PYLON SKIN. REPAIRED IAW EA 757-54 50-27-A2090.SDR IPXA1570734Power Supply · inoperativeEMERGENCY EXIT LIGHT HAS MANY LAMPS BURNED OUT. AFTER RELAMP, UNIT WILL NOT TEST. R & R EMERGENCY EXIT LIGHT POWER SUPPLY CHARGER IAW 33-51-07-2. ALL LAMPS TEST NORMAL NOW.SDR IPXA11569606Engine · vibrationLT ENGINE N3 VIBRATION INDICATED 2.7 DURING CLIMB FOR 340-370. RETURNED TO NORMAL RANGE AFTER LEVEL OFF. NO OTHER VIBRATIONS NOTED DURING RETURN. N3 91 PERCENT, N2 90 PERCENT, EGT 710. IAW TECH ALERT K151367 REINSTALLED ORIGINAL BAL WEIGHTS TO PREVIOUS BALSDR IPXA11567491Lamp · inoperativeINSPECTION TYPE:PS, DURING PSC THE EMERGENCY EXIT EGRESS LIGHT WAS INOP. REPLACED LAMP IAW AMM-51-06-2-3.SDR IPXA1566648Skin · dentedINSPECTION TYPE:C1 RT SIDE FUSELAGE LOWER LOBE FWD OF NR 1 CARGO DOOR HAS DENT ON EXTERIOR SKIN AND STRINGER 25R 305 INCHES FWD OF STA 540. CUT OUT DAMAGE AMD FABRICATED AND INSTALLED FILLER AND DOUBLER IAW SRM 53-00-01-2R-2, EA 110436 IR AND EO B757-5330-426SDR IPXA1566646Stringer Clip · mismanufacturedINSPECTION TYPE:C1, STRINGER CLIP, 143N2063-7 DOES NOT HAVE PROPER EM. FABRICATED NEW STRINGER CLIP FROM BAC1518-730 MATERIAL.SDR IPXA1566611Frame · dentedINSPECTION TYPE:C1, AFT CARGO COMPARTMENT STA 1300 JUST BELOW STR 25R, FRAME IS DENTED ON INBD FLANGE. REMOVED DAMAGE AND REPAIRED FRAME AT STR 25R IAW EA 110442 IR.SDR IPXA11566548Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO COMPARTMENT FLOOR PANEL 252XUF HAS 2 DAMAGED INSERTS. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1566645Frame · dentedINSPECTION TYPE:C1, AFT CARGO COMPARTMENT STA 1240 BETWEEN STR 23L AND 24L FRAME IS DENTED ON INBD FLANGE. CUT OUT DAMAGE. FABRICATED AND INSTALLED REPAIR ANGLE AND STRINGER CLIP IAW SRM 53-00-07-2R 5, DETAIL III, EA 11044 IR.SDR IPXA11566549Floorboard · damagedINSPECTION TYPE:C1, DAMAGE ON UPPER SURFACE OF MAIN DECK FLOORBOARD 251XRF. FABRICATED REPLACEMENT FLOORBOARD NR 251XRF IAW B757-5320-9692-G.SDR IPXA11566580Shear Web · corrodedINSPECTION TYPE:C1, CABIN FLOOR SHEAR WEB AT BODY STA 1700+3 AND LBL 41, WEB IS CORRODED. REMOVED CORROSION, ORIGINAL THICKNESS .071, LOSS OF .010 WITH .061 MATERIAL LOSS IS OUT OF LIMITS IAW SRM 53-00-51-1A1. ACCOMPLISHED EA 1104 54/ EO B757-5310-42643-A FORSDR IPXA1566653Frame · dentedINSPECTION TYPE:C1, LOWER FWD CARGO PIT FRAME AT STA BS 840, BELOW STRINGER 24L FREE FLANGE IS DENTED. REPAIRED FRAME AT BS 840 STR 24L IAW EA 110439.SDR IPXA1566652Frame · dentedINSPECTION TYPE:C1, LOWER FWD CARGO COMPARTMENT FRAME AT STA 870, AT STR 24L, INBD FREE FLANGE IS DENTED. CUT OUT DAMAGE. FABRICATED REPAIR J, SHEAR TIE AND STRINGER CLIP INSTALLED IAW SRM 53-00-07-2R 5 DETAIL III AND EA 110438.SDR IPXA1566651Frame · dentedINSPECTION TYPE:C1, AFT CARGO COMPARTMENT STA 1260, STR 26L FRAME IS DENTED ON INBD FLANGE. CUT OUT DAMAGE. FABRICATED AND INSTALLED REPAIR ANGLE, SHEAR TIE AND STRINGER CLIP IAW SRM 53-00-07-2R 5 DETAIL III AND EA 110443 IR.SDR IPXA1566649Frame · dentedINSPECTION TYPE:C1, AFT CARGO COMPARTMENT STA 1260 JUST BELOW STR 25R, FRAME IS DENTED ON INBD FLANGE CUT OUT DAMAGE. FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-07-2R-5 AND EA11044 IR.SDR IPXA1566647Frame · dentedINSPECTION TYPE:C1, LOWER FWD CARGO PIT FRAME AT BS 660 BETWEEN STRINGER 24R AND 25R, IS DENTED ON INBD FREE FLANGE CUT OUT DAMAGE. FABRICATED AND INSTALLED REPAIR ANGLES SHEER TIE AND STRINGER CLIPS IAW SRM 53-00-07-2R 5 DETAIL III AND EA 110434 IRSDR IPXA1566353Frame · dentedINSPECTION TYPE:C1, LOWER FWD CARGO PIT FRAME AT BS 720 BELOW STRINGER 23L, IS DENTED. REMOVED DAMAGED SECTION OF FRAME AT STA 720, STR 23L. FABRICATED REPAIR PARTS FROM 7075-T6.071. INSTALLED REPAIR IAW SRM 53-00-07-2R5, DETAIL 1.SDR IPXA10562903Frame · damagedFRAME STA 1500 DAMAGED. REPAIRED IAW EO B757-5310-39805-A.SDR IPXA10562432Logic Card · inoperativeEICAS MESSAGE RT ENGINE OVERHEAT DISPLAYED AND RT ENGINE OVERHEAT LIGHT ILLUMINATED. LIGHT REMAINED ON AFTER THRUST REDUCTION. ENGINE WAS SHUTDOWN. T/S IAW FIM AND AMM 26-10-01. R & R BOTH LOGIC CARDS M10224 AND M10274 AND OPS CHECK IAW MM 26-10-1-4. ALL OSDR IPXA10558741Skin · dentedLT HORIZ STAB DENTED. REPAIRED PER EO B757-5510-36400-A.SDR IPXA09556290Floor Panel · defectiveINSPECTION TYPE:C2 FABRICATE NEW FLOOR PANEL FROM BS 1020 TO BS 1055 BL 0 TO RBL 25. EXISTING FLOOR PANEL DOES NOT LINE UP WITH NEW FLOOR SUPPORT AT BS 1055. FABRICATED NEW FLOOR PANEL IAW SRM ADDENDUM B757-5320-9692-G.SDR IPXA09556291Floor Panel · defectiveINSPECTION TYPE:C2 FABRICATE NEW FLOOR PANEL FROM BS 1040-1060 LBL 0 - RBL 25. EXISTING FLOOR PANEL DOES NOT LINE UP WITH NEW FLOOR SUPPORT AT BS 1060. FABRICATED NEW FLOOR PANEL IAW SRM ADDENDUM B757-5320-9692-G.SDR IPXA09556226Intercostal · corrodedINSPECTION TYPE:C2 CORROSION AND TOOLING MARKS ON INTERCOSTAL AT BS 1055 RBL 27-43 WL 208. BLENDED CORROSION AND TOOLING MARKS FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED PER SRM 51-40-05 AND OHM 20-50-01.SDR IPXA09556225Intercostal · corrodedINSPECTION TYPE:C2 CORROSION AND TOOLING MARKS ON INTERCOSTAL AT BS 1020 RBL 2-22 WL 208. BLENDED CORROSION AND TOOLING MARKS FOUND REWORKED AREAS TO BE OUT OF LIMITS, REPLACED INTERCOSTAL PER SRM 51-40-05 AND OHM 20-50-01.SDR IPXA09556289Floorbeam · corrodedINSPECTION TYPE:C2 CORROSION ON THE BS 1200 FLOORBEAM FWD FLANGE RBL 30 TO RBL 60. REMOVED DAMAGED / CORRODED FLOORBEAM AREA. FABRICATED AND INSTALLED NEW FLOORBEAM SECTION IAW ER 09-2975.SDR IPXA09556262Floorbeam · corrodedINSPECTION TYPE:C2 CORROSION ON BS 1200 FLOORBEAM FWD FLANGE BL 0 TO LBL 55 WL 208. BLENDED CORROSION FROM FLOORBEAM BS 1200 LBL BL 0 AND SUBMITTED ENGINEERING, FABRICATED REPAIR ANGLE, NDI ALL HOLES, ALODINE AND PRIMED PARTS INSTALLED REPAIR ANGLE PER ER E09SDR IPXA09556248Strap · corrodedINSPECTION TYPE-C2 APU INLET CUTOUT, AFT OUTER STRAP PN 148N3138-8000 IS CORRODED BEYOND THE SRM LIMITS, BS 1824, BETWEEN STR 3-6R. REMOVED, FABRICATED AND INSTALLED NEW STRAPS AND REPAIR PARTS COMMON TO APU INLET CUT OUT IAW ER 09-2965. SRM 51-40-05, SRM 51-SDR IPXA09556247Beam · corrodedINSPECTION TYPE:C2 CORROSION ON LONGITUDINAL BEAM FLANGE BS 1046 LBL 26 WL 208. REMOVED AND REPLACED LONGITUDINAL BEAM FROM BS 1040-1080 LBL 25 WL 208 IAW SRM 51-40-05-00 SRM 51-40-08-0G AND SRM 51-10-02-0G.SDR IPXA09556296Floorbeam · corrodedINSPECTION TYPE:C2 CORROSION ON TOP OF FLOORBEAM AT BS 100 LBL 7-55 WL 208. REPAIRED PER ATS ER 09-2958.SDR IPXA09556259Floorbeam · corrodedINSPECTION TYPE:C2 CORROSION ON TOP OF FLOORBEAM AT BS 1200 LBL 55 RBL 55 WL 208. REPAIRED PER ATA ER 09-2975 DATED 07JUN09.SDR IPXA09556258Seat Track · corrodedINSPECTION TYPE:C2 CORROSION ON SEAT TRACK FLANGE BS 1183 LBL 60 WL 208. REPAIRED PER ATS ER 09-2960 DATED 07JUN09.SDR IPXA09556246Intercostal · corrodedINSPECTION TYPE:C2 CORROSION ON INTERCOSTAL AT BS 1016 LBL 34-40 WL 208. BLENDED DAMAGE, FOUND OUT OF LIMITS. REMOVED AND REPLACED INTERCOSTAL AT BS 1016, LBL 34-40, WL 208 PER SRM 51-40-02.SDR IPXA09556245Intercostal · corrodedINSPECTION TYPE:C2 CORROSION AND TOOLING MARKS ON INTERCOSTAL AT BS 1055, LBL 2-22 WL 208. BLENDED DAMAGE AREA, FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED INTERCOSTAL AT BS, 1055, LBL 2-22, WL 208, PER SRM 51-40-02.SDR IPXA09556244Intercostal · corrodedINSPECTION TYPE:C2 CORROSION AND TOOLING MARKS ON INTERCOSTAL AT BS 1055, LBL 28-38, WL 2 208. BLENDED AREA OF DAMAGE, FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED INTERCOSTAL AT BS 1055, LBL 28-38, WL 208 PER SRM 51-40-02.SDR IPXA09556224Skin · gougedINSPECTION TYPE:C2 GOUGE IN SKIN INTERNAL SURFACE AT BS 442, 2 INCHES O/B OF STRINGER 27. BLENDED GOUGE. NOTED PRIMED IAW UPS EO B757-5330-33771-A.SDR IPXA09556223Intercostal · corrodedINSPECTION TYPE:C2 CORROSION ON INTERCOSTAL AT BS 1061 LBL 49-54 WL 208. CORRODED OUT OF LIMITS, REPLACED IAW SRM 51-40-02.SDR IPXA09556257Seat Track · corrodedINSPECTION TYPE:C2 CORROSION ON SEAT TRACK FLANGE BS 1173-1185 RBL 60 WL 208. REPAIRED PER ATS ER 09-2959 DATED 07JUN09.SDR IPXA09556228Intercostal · corrodedINSPECTION TYPE:C2 CORROSION AND TOOLING MARKS ON INTERCOSTAL STA 1056 RBL 48-59 WL 208. REMOVED & REPLACED PER SRM 51-40-02, SRM 51-40-05, SRM 51-20-01.SDR IPXA09556256Bulkhead · migratedINSPECTION TYPE:C2 NR 2 PYLON STRUT MID-BULKHEAD, COMMON TO I/B LOWER CHORD, HAS EVIDENCE OF SHIM MIGRATION. TRIMMED EXPOSED PLIES OF MIGRATION SHIM ON NR 2 PYLON I/B FWD SIDE OF MID BULKHEAD COMMON TO LOWER CHORD .150 X 1.9 INCH FLUSH TO MID-BULKHEAD IAW EO SDR IPXA09556227Support Angle · corrodedC2 TAIL COMPARTMENT INTERIOR RT SIDE APU INLET DUET FWD LWR CORNER HAS CORROSION AT NUTPLATE REMOVED, FABRICATED AND INSTALLED CORRODED SUPPORT ANGLES AND STRAPS COMMON TO APU INLET DOOR HSG. REMOVED AND INSTALLED APU DOOR IAW SRM 51-10-02-0G, SRM 53-00-01-1SDR IPXA09555958Engine · vibrationATB - RT ENG VIB'S 5.0, ACCOMPLISHED FIM 77-31-00 FIG 103. NO FAULTS NOTED.SDR IPXA09556261Skin · misrepairedINSPECTION TYPE:C2 REPAIR VALIDATION REQUIRED FOR SEQUENCE 465-F1-02, BS 1461.5- 1480-5 STR 25R. DOES NOT CONFORM TO EFN SRM. REPAIRED PER ATS ER 09-2974 DATED 07JUN09.SDR UPS09554285Engine · vibrationEXCESSIVE VIBRATION NR 2 ENGINE. VIBRATION REGISTERED 5.0. CREW DECLARED EMERGENCY AND DIVERTED. FUMES EMINATED FROM OVERHEAD PANEL. NR 2 ENGINE PACK SHUTDOWN. INSPECTED INLET LP N1 BLADES, NOSE COWL AND EXHAUST AREA. NO DAMAGE OR OIL LEAKS FOUND. ACCOMP. FIM
Back to N465UP