N622AE
Service difficulty reports · 183
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N622AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N622AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA200602327Floor Support · corrodedA PREVIOUS REPAIR ON THE LT OMEGA BEAM AT FRAME 20 WAS FOUND TO BE CORRODED. REMOVED THE CORRODED REPAIR. PREPARED A FILLER DOUBLER, SHIMS AND PLATE. REPAIR DONE IAW SRM. (K)SDR SIMA200419404Light · inoperativeDFW - FLT 3533 - FOUND EMERGENCY EXIT LIGHT ABOVE GALLEY INOPERATIVE. REPLACED EMERGENCY LIGHT LOCATOR IAW EMB MM 33-50-00. OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR SIMA200417204Skin Panel · bird strikeDURING MBV INSPECTION THE LT FORWARD FUSELAGE SKIN DAMAGED FROM BIRD STRIKE. REPLACED DAMAGED SKIN IAW SRM.SDR SIMA200417205Bearing · wornDURING MBV INSPECTION, THE RT AND LT HORIZONTAL STABILIZER HINGE BEARINGS WERE FOUND TO HAVE PLAY. REMOVED AND REPLACED RT AND LT HORIZONTAL TO VERTICAL SPHERICAL BEARINGS IAW MFG AMM AND SB.SDR SIMA200417206Thrust Reverser · crackedDURING MBV INSPECTION THE RT THRUST REVERSER HAS APPROXIMATE 3 INCH CRACK AT THE FORWARD LOWER OB SECTION. REPAIRED CRACK IAW MFG SRM.SDR SIMA200417207Bushing · wornDURING MBV INSPECTION THE LT HORIZONTAL STABILIZER OB BUSHING WAS FOUND TO BE MIGRATING. REPLACED BUSHINGS IAW MFG SRM.SDR SIMA200417209Channel · wornDURING MBV INSPECTION THE SERVICE DOOR SILL BETWEEN FRAMES 20 AND 22 RT SIDE WAS FOUND CORRODED. REMOVED AND REPLACED THE CHANNEL IAW MFG SRM.SDR SIMA200306204Landing Gear · malfunctionedOMA - FLT 4108 - AFTER TAKEOFF, THE CREW RECEIVED A LANDING GEAR DISAGREE MESSAGE WHEN GEAR HANDLE WAS SELECTED UP. THE RIGHT MLG DID NOT RETRACT. CREW RETURNED TO OMA WITH NO FURTHER INCIDENTS REPORTED. CFR DID RESPOND. (M)SDR SIMA200216201Beam · elongatedDURING AN IMBV INSPECTION FOUND CENTER BEAM UPRIGHT AT FRAME 20 HAD AN ELONGATGED HOLE. REMOVED DAMAGED UPRIGHT. FRABRICATED A SERVICEABLE UPRIGHT IAW STANDARD SRM PRACTICES.SDR SIMA200215901Floorbeam · corrodedABI - DURING AN IMBV INSPECTION MAINTENANCE, FOUND CORROSION ON GALLEY RIGHT FLOORBEAM. REMOVED CORRODED GALLEY RIGHT BEAM. INSTALLED NEW BEAM IAW EMB SRM 145/1142, CHAPTER 51, REV 18, 51-40-02, GST-1826/02, ITEM NR 1, AND STANDARD SRM PRACTICES. (M)SDR SIMA200215801Floorbeam · corrodedABI - DURING AN IMBV INSPECTION, FOUND CORROSION ON GALLEY CENTER FLOORBEAM. REMOVED CORRODED GALLEY CENTER BEAM. INSTALLED NEW CENTER BEAM IAW EMB 145 SRM 145/1142, CHAPTER 51, REV 18, 51-40-02, ETN-EM53-020, AND STANDARD SRM PRACTICES. (M)SDR SIMA200215803Frame · dentedABI - DURING AN IMBV INSPECTION, FOUND LOWER PORTION OF RIGHT FRAME 72 DENTED. RECONTOURED DENT. PERFORMED NDT, NO DEFECTS. FABRICATED TWO L SHAPE DOUBLERS. INSTALLED IAW EMB GST-1776/02, ITEM NR 3 GST-1784/02, AND STANDARD SRM PRACTICES. (M)SDR SIMA200215802Floorbeam · corrodedABI - DURING AN IMBV INSPECTION, FOUND CORROSION ON LEFT OMEGA BEAM BETWEEN FRAMES 24 AND 25. REMOVED CORROSION BY CUT OUT. FABRICATED A DOUBLER ANGLE, TWO SHIMS. INSTALLED IAW EMB 145 SRM 145/1142, CHAPTER 53, REV 18, 53-21-10, AND STANDARD SRM PRACTICES. SDR SIMA200215712Sill · corrodedDURING AN IMBV INSPECTION, FOUND CARGO DOOR LOWER SILL PLATE BETWEEN FRAMES 65 AND 68 CORRODED. REMOVED CORRODED SILL (BEAM). INSTALLED NEW BEAM IAW EMB 145 (SRM 145/1142, CHAPTER 51, REV 18, 51-20-03, 51-40-02 AND STANDARD SRM PRACTICES. (M)SDR SIMA200215711Clip · corrodedABI - DURING AN IMBV INSPECTION, FOUND CARGO DOOR CUT OUT SHEAR CLIP CORRODED. REMOVED CORRODED SHEAR CLIP. INSTALLED NEW CLIP IAW EMB 145 SRM 145/1142, CHAPTER 51, REV 18, 51-20-03, 51-40-02, ETN EM-51-020 AND STANDARD SRM PRACTICES. (M)SDR SIMA200215708Stringer · corrodedABI - DURING INSPECTION FOUND STRINGER 19L CHAFED AT FRAME 53. BLENDED CHAFE. FABRICATED AND INSTALLED DOUBLER ANGLE, WITH TWO SHIMS IAW EMB 145 (145/1142, CHAPTER 53, REV 18) 532-24-02, ETN EM-51-020, AND STANDARD SRM PRACTICES. (M)SDR SIMA200215709Doubler · corrodedABI - DURING INSPECTION FOUND CORROSION ON PREVIOUS REPAIR FORWARD DIGITAL. REMOVED PREVIOUS REPAIR. FABRICATED AND INSTALLED DOUBLER, IAW EMB SST-2906/00, AND STANDARD SRM PRACTICES. (M)SDR SIMA200215710Doubler · corrodedDURING INSPECTION, FOUND CORROSION ON LEFT OMEGA BEAM PREVIOUS REPAIR AT FRAME 20. REMOVED PREVIOUS REPAIR. FABRICATED AND INSTALLED DOUBLER ANGLE, FILLER, PLATE, WITH TWO SHIMS IAW EMB 145, SRM 145/1142, CHAPTER 53, REV 18, 53-21-10, AND STANDARD SRM PRACTISDR SIMA200216304Floorbeam · corrodedABI - THIS IS A LEVEL 2 FINDING, CORROSION ON LEFT OMEGA BEAM UNDER EDGE OF COMPOSITE FLOOR CROSSBEAM BETWEEN FRAMES 24-25. FABRICATED AND INSTALLED A DOUBLER, IAW EMB145 SRM 53-21-10. (M)SDR SIMA200216306Floor Support · corrodedTHIS IS A LEVEL 2 FINDING, GALLEY CENTER BEAM GUSSET HAS CORROSION. C/A-REMOVED AND REPLACED GUSSET IAW SRM.SDR SIMA200216301Support · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY RAMP SUPPORT HAS CORROSION. REMOVED AND INSTALLED SERVICEABLE GALLEY RAMP IAW EMB 145 SRM 51-40-02. (M)SDR SIMA200216302Floorbeam · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY RIGHT HAT BEAM HAS CORROSION. INSTALLED SERVICEABLE RIGHT HAT BEAM IAW EMB145 SRM 51-40-02 AND GST-1826/02. (M)SDR SIMA200216303Sill · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY RIGHT SILL (FORWARD) HAS CORROSION. REMOVED AND INSTALLED FORWARD SILL IAW EMB 145 SRM 51-40-02. (M)SDR SIMA200214702Sill · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY RIGHT AFT SILL HAS CORROSION. INSTALLED SERVICEABLE AFT SILL IAW EMB145 SRM 51-40-02. (M)SDR SIMA200214703Floorbeam · corrodedTHIS IS A LEVEL 2 FINDING, LEFT OMEGA BEAM PREVIOUS REPAIR AT FRAME 20 HAS CORROSION. INSTALLED SERVICEABLE REPAIR DOUBLER, FILLER, PLATE AND SHIMS IAW EMB145 SRM 53-21-10. (M)SDR SIMA200214701Sill · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY LEFT SILL HAS CORROSION. INSTALLED SERVICEABLE SILL IAW EMB145 SRM 51-20-03, 51-40-06 AND 51-40-02. (M)SDR SIMA200216307Floor Support · corrodedTHIS IS A LEVEL 2 FINDING ON CRIC NR 36201. GALLEY FORWARD DIAMOND GUSSET HAS CORROSION INSTALLED SERVICEABLE DIAMOND GUSSET IAW SRM.SDR SIMA200216305Crossbeam · corrodedTHIS IS A LEVEL 2 FINDING ON CRIC NR 36200. GALLEY CROSSBEAM AND PROFILE HAS CORROSION AT FRAME 23. C/A- INSTALLED NEW CROSSBEAM AND PROFILE IAW SRM.SDR SIMA200102703Actuator · failedMEM - FLT 3256 - DURING CLIMB, CREW REPORTED CHATTERING NOISE FROM RELAYS FOLLOWED BY THE PITCH TRIM SWITCHES FOR THE FIRST OFFICER AND THE CAPTAIN NOT RESPONDING. CREW RETURNED TO MEM. DURING RETURN CREW HEARD ONE CLICK FROM A RELAY FOLLOWED BY BOTH FIRST OSDR SIMA200102003Control Unit · failedCID - FLT 3954 - AFTER TAKEOFF, THE CAPTAIN AND FIRST OFFICERS YOKE TRIM SWITCHES FAILED. REMVOED AND REPLACED HORIZONTAL STABILIZER CONTROL UNIT IAW AMM. OPS CHECK GOOD. FCF GOOD. (M)SDR SIMA0206Control Unit · failedCID - FLT 3954 - AFTER TAKEOFF, THE CAPTAIN AND FIRST OFFICERS YOKE TRIM SWITCHES FAILED. MAINTENANCE REMOVED AND REPLACED HORIZONTAL STABILIZER ELECTRONIC CONTROL UNIT. AIRCRAFT PASSED A FUNCTIONAL CHECK FLIGHT AND WAS RETURNED TO SERVICE. (M)SDR SIMA3582Control Unit · malfunctionedDFW - FLT 3560 - WHILE HAND FLYING PITCH TRIM MOVED DOWN WITHOUT PITCH DOWN IMPUT FROM PILOT. PERFORMED READING OF THE FDR AND VERIFIED THAT THERE WAS NO RECOREDED MOVEMENT OF THE HORIZONTAL STAB. REPLACED HORIZONTAL STAB CONTROL UNIT AND PERFORMED SYSTEM TESDR SIMA2382Smoke Detector · false indicationCLE - FLT 4216 - ON CLIMB-OUT, RECEIVED BAG SMOKE INDICATION. DECLARED EMERGENCY INTO CLE AND DISCHARGED THE FIRE BOTTLES. MAINTENANCE COMPLIED WITH OPERATIONAL CHECK OF BAGGAGE SMOKE DETECTION SYSTEM AND FOUND NO DISCREPANCY. FIRE BOTTLES WERE REPLACED AND
Back to N622AE