N641GT
Service difficulty reports · 1,011
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N641GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N641GT' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2016121701025Valve · failedMTC MESSAGE RT PACK BITE. CONTROLLER FAULTED RT PACK LOW CONTROL VALVE, REPLACED LOW LIMIT VALVE REF AMM 21-51-11, OPS CHECK OK.SDR UIEA2016121901047Circuit Card · inoperativeLEFT SPAR VALVE FAILED ON ENGINE SHUT DOWN. TROUBLESHOT IAW FIM 28-22 14, R & R THE LT SPAR VALVE LIGHT DIODE, FUSE CARD IAW AMM 33-16-02. OPS CHECKED OK.SDR UIEA2016121000996Valve · malfunctionedEICAS MESSAGE FOR RT ENGINE ANTI-ICE, QRH PROCEDURE PERFORMED. CONFIRMED VALVE OPERATION IAW AMM 30-21-03. REMOVED AND REPLACED THE RT ENGINE TAI VALVE IAW AMM 30-21-03. LEAK AND OPS CHECKED, NDICATIONS NORMAL.SDR UIEA2016120100948Pressure Switch · leakingON POST FLIGHT WALK AROUND, FOUND OIL DRIPPING FROM APU COWLING. REMOVED AND REPLACED LOW OIL PRESSURE SWITCH IAW AMM 49-94-02. NO LEAKS NOTED.SDR UIEA2016112900910Controller · malfunctionedRIGHT PACK TEMP CONTROL FAULT. REMOVED AND REPLACED THE RIGHT A/C PACK CONTROLLER ASSY IAW AMM 21-51-14. OPS CHECKED NORMAL.SDR UIEA2016112900909Controller · failedLEFT PACK TEMP CONTROL FAULT. R & R THE A/C PACK CONTROLLER. OPS CHECKED GOOD IAW AMM 21-51-14.SDR UIEA2016111800846Valve · failedECS MESSAGE LT PACK. REMOVED AND REPLACED LT PACK TEMP CONTROL VALVE IAW AMM 21-51-12. OPS & BITE CHECKED GOOD .SDR UIEA2016111500842A/C Pack · faultedLEFT PACK TEMP EICAS MESSAGE. PERFORMED BITE ON LT PACK CONTROLLER IAW FIM 21-51 FT 803. FAULTED LT PACK TEMP CONTROL VALVE. RESET LT PACK CONTROLLER PERFORMED BITE PREOCEDURE A SECOND TIME. NO CURRENT FAULTS NOTED. NO EICAS MSGE PRESENT. ACFT OK FOR SERVICSDR UIEA2016110900833Module · failedUNABLE TO CLEAR AIR SUPPLY BITE MODULE FAULTS. REMOVED AND REPLACED AIR SUPPLY BITE MODULE.SDR UIEA2016110900834Relay · failedRIGHT FWD BOOST PUMP PRESS LIGHT INDICATION ON PUSH BUTTON SWITCH FAILED TO COME ON WITH GFI TRIPPED. REMOVED AND REPLACED TIME DELAY RELAY (K-5) ON FUEL CONTROL PANEL FOR RIGHT FWD BOOST PUMP PRESS LIGHT INDICATION.SDR UIEA2016110900835Circuit Breaker · brokenRIGHT FUEL JETTISON PUMP CIRCUIT BREAKER (C376) ON P37 BROKEN. REMOVED AN REPLACED THE CIRCUIT BREAKER.SDR UIEA2016110900836Inverter · inoperativeEMERGENCY LIGHTS INOPERATIVE. REPLACED THE LAMPS, CONNECTED THE CONNECTOR FOR SEATS 4-9CA, REMOVED AND REPLACED THE INVERTER, REMOVED AND REPLACED AFT GALLEY EMERGENCY LIGHT ASSY.SDR UIEA2016110900837Power Supply · inoperativeLEFT AND RIGHT OVERWING EMERGENCY LIGHTS FOUND INOPERATIVE. REPLACED THE LAMPS, CLEANED AND REPLACED THE POWER SUPPLY. OPS CHECKED GOOD.SDR UIEA2016102800825Panel · brokenON POST FLIGHT INSPECTION FOUND PANEL 651VB BROKEN, MLG STRUT DOOR BOLT MISSING & MLG TRUNNION DOOR & LEADING EDGE DAMAGED. PERFORMED TEMP REPAIRS PER EO 6757A120 & EO 6752A038. REMOVED STRUT DOOR PER CDL 32-12-01.SDR UIEA2016101800817Processor · faultedAFTER TAKE OFF FUEL QTY WAS ERRATIC THEN SETTLED AFTER LEVEL OUT. TROUBLESHOT IAW FIM. FAULTED PROCESSOR REMOVED AND REPLACED IAW AMM 28-41-08 OPS CHECK AND BITE CHECKED NORMAL.SDR UIEA2016100500801Eec · malfunctionedAPU SHUTDOWN. REMOVED AND REPLACED APU ECU IAW AMM 49-61-05. OPS CHECKED NORMAL.SDR UIEA2016100500803Cover · missingEMERGENCY LIGHT COVER AT SEAT 38J IS MISSING. REPLACED THE EMERGENCY LIGHT COVERS IAW MM 25-27-09.SDR UIEA2016092300770Bulb · inoperativeRIGHT PACK COMPRESSOR OUTLET TEMP INDICATION BLANK. R & R RT PACK COMPRESSOR OUTLET TEMP BULB. OPS CHECK GOOD IAW AMM 21-52-01.SDR UIEA2016083000719Apu · leakingAPU OIL QTY MESSAGE ON STATUS PAGE. OIL FOUND IN TAIL PIPE. TRANSFERRED TO DMI; MDDR 69791 IAW MEL 49-11-01B, CAT B. REMOVED AND REPLACED APU IAW WORK CARD T1071 AMM 49-11-01.SDR UIEA2016082500703Engine · stalledLEFT ENGINE COMPRESSOR STALLS WITH HEAVY YAW APPROX 13000-14000. REDUCED THRUST TO IDLE AND RETURNED TO DEPARTURE. REMOVED AND REPLACED THE ENGINE, OPS CHECKED OK. ACFT RELEASED FOR SERVICE.SDR UIEA2016080100655Mask · damagedMAIN CABIN R4 PBE DAMAGED. REMOVED AND REPLACED PBE MASK IAW AMM 25-60-00.SDR UIEA2016080100652Bushing · wornL4 DOOR OPENING HANDLE LOOSE WHEN CLOSED. REPLACED THE HANDLE WORN BUSHING IAW AMM 52-11-25. NO RIGGING WAS REQUIRED. DOOR HANDLE OPERATED NORMAL.SDR UIEA2016080100653Life Raft · low pressureMAIN CABIN ROW 20 LIFE RAFT PRESSURE GAUGE READS LOW. REMOVED THE RAFT ASSY. ROUTED TO VENDER FOR SERVICE IAW AMM 25-05-03. REINSTALLED RAFT ASSY.SDR UIEA2016073100646Light · inoperativeMAIN CABIN LEFT EMERGENCY LIGHT BETWEEN ROW 39 AND AFT GALLEY FLOOR LIGHT INOPERATIVE. REMOVED AND REPLACED THE LIGHTS IAW AMM 33-53-00 OPS CHECKED OK.SDR UIEA2016073100649Light · inoperativeMAIN CABIN ROW 9 RIGHT FLOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT IAW AMM 33-53-00. OPS CHECKED OK.SDR UIEA2016073100645Light · inoperativeMAIN CABIN EMERGENCY LIGHT ROW 5 LT AISLE CEILING INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT.SDR UIEA2016073100647Light · inoperativeMAIN CABIN ROW 31 FLOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-53-00. OPS CHECKED OK.SDR UIEA2016073100648Light · inoperativeMAIN CABIN ROW 32 FLOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-53-00, OPS CHECKED OK.SDR UIEA2016073100650Connector · unsecureRIGHT ROW 40 FLOOR EMERGENCY LIGHTS INOPERATIVE. FOUND LOOSE CONNECTOR ROW 40. CLEANED AND RESET CONNECTOR. EMERGENCY LIGHTS OPS OK. IAW SSM 33-51-01.SDR UIEA2016072700641Warning Message · false activationAFTER LANDING STATUS MESSAGE FUEL QTY CHANNEL. FQIS PROCESSOR BITE TEST CARRIED OUT IAW AMM 28-41-00, ALL TESTS PASSED, MESSAGE ERASED.SDR UIEA2016071900598Seal · leakingRIGHT PACK BAY AIR LEAK ABOVE RE-HEATER CONTROLLER. REPLACED THE SEALS. LEAK CHECKED OK IAW MM 21-51-00.SDR UIEA2016071400584Filter · damagedON POST FLIGHT WALK AROUND, FOUND RT ENG IDG FILTER DP BUTTOM POPPED. REPLACED THE FILTER IAW MM 24-11-02.SDR UIEA2016070800572Warning Message · false activationRIGHT BLEED DUCT LEAKING. PERFORMED OPS CHECK OF AIR SUPPLY SYSTEM. SYSTEM CHECKED NORMAL IAW MM 36-21-00.SDR UIEA2016070700569Fan · failedFWD EQUIP OVERHEAT MESSAGE. REMOVED AND REPLACED THE FWD EQUIPMENT SUPPLY FAN IAW AMM 21-58-06, OPS NORMAL.SDR UIEA2016070700568Warning Message · false activationEQUIPMENT OVERHEAT MESSAGE. ACCOMPLISHED QRH SELECRTOR TO STBY FOR 5 MIN THEN OVRD FOR 30 MIN. SELECTOR BACK TO AUTO . OVERHEAT LIGHT EXTINGUISHED . CONT FLIGHT NORMAL. PERFORMED EQUIPMENT COOLING TEST IAW AMM 21-58-00. NO FAULTS FOUND AT THIS STATION.SDR UIEA2016063000542Actuator · failedLT SPAR VALVE NO INDICATION ON ENGINE START. REMOVED AND REPLACED FUEL SHUTOFF ACTUATOR IAW AMM 28-22-11.SDR UIEA2016061500422Eec · faultySTATUS MESSAGE LT ENGINE, ELECTRONIC ENGINE CONTROL T/S IAW FIM 71-00, TASK A17. R & R LT ENGINE, ENGINE CONTROL UNIT IAW AMM 73-21-13, RAN ENGINES. OPS CHECK NORMAL.SDR UIEA2016061400421Warning Message · false activationSTATUS MSG, LT ENGINE, ELECTRONIC ENGINE CONTROL, C1 CLEARED MSG IAW AMM 31-35-00, TEST OF THE LT PIMU IAW FIM 71-01, TR 811, FAULT CLEARED. OK FOR SERVICE.SDR UIEA2016061100420Warning System · false activationLEFT ENGINE ELECTRONIC ENGINE CONTROL C1, PERFORMED ELECTRONIC ENGINE CONTROL LT PIMU BITE, CK 350-18A LATCHED RESET CLEARED, CHECKED CONNECTOR PLUG CONNECTORS ON ENGINE. ELECTRONIC ENGINE CONTROL UNIT, CHECKED CONNECTOR PLUG AT PYLON CONNECTOR, NO DEFECTS FISDR UIEA2016060900410Status Message · false activationSTATUS MESSAGE, LT ENGINE ELECTRONIC ENGINE CONTROL C1. CLEARED MESSAGE IAW AMM 31-35-00, PERFORMED TEST OF LT PIMU, DATA MODE DISAGREE, FOLLOWED FIM 71-01 F, TREE 811, CLEARED FAULTS SYS, CKS NORMAL.SDR UIEA2016060100366Connector · unsecureRIGHT ENG IGNITOR 1 STATUS MSG. PLACED ON MEL 74-00-01B, MDDR 67109. SECURED CONNECTOR SOCKETS AT AW0325 CONNECTION SYS TEST IAW AMM CH 74-00-00. RT ENG IGNITOR OPERATES NORMAL MDDR 97109 CLOSED.SDR UIEA2016060100365Exciter · malfunctionedRIGHT ENG IGNITER 1 R & R RT ECU AMM 73-21-13 & RT ENG NR 1 IGNITER EXCITER IAW AMM 74-11-01. OPERATIONS CHECKED NORMAL.SDR UIEA2016052800356Status Message · false activationRIGHT ENG IGNITOR 1 STATUS MSG. MSG CLEARED USING MCDP EICAS ERASE PROCEDURES IAW AMM 31-41-02. SYS CHECKED OK FOR SERVICE.SDR UIEA2016052500353Controller · defectiveRIGHT ENG HPSOV STATUS MSG. PLACED ON DDG 36-11-02-02 & MDDR 66954. RT HP CONTROLLER REPLACED ON LP 764074 , M3. REACTIVATED HP VALVE, SYSTEM TESTED NORMAL DURING ENG RUN PER MM CH 36-11-07. MDDR CLEARED.SDR UIEA2016052500352Connector · looseRIGHT ENG IGNITER 1 STATUS MSG. PLACED DEFERRAL 74-00-01B MDDR 66953. FOUND CONNECTOR ON EXCITER BOX LOOSE, TIGHTENED SAME OPS CHECKS GOOD THIS CLEARS MDDR 66953 AMM 74-11-01.SDR UIEA2016052300346Engine · leakingDURING POWER RUN POST WALK, FOUND NR 2 ENG WITH OIL LEAK FROM AFT BEARING LINE. R & R RT ENG ASSEMBLY IAW WO 15415. LEAK & OPERATIONS CHECKED GOOD.SDR UIEA2016052300345Fitting · disconnectedRT STRUT DUCT LEAK EICAS MSG. FOUND PRE COOLER EXHAUST FITTING DISCONNECTED BETWEEN PRE COOLER & PRSOV. REPOSITIONED FLANGE & SEAL ASSEMBLY IAW AMM 36-11-15, RAN HIGH POWER IAW AMM 71-00-00, ALL OPERATIONS CHECKED GOOD.SDR UIEA2016052100343Acm · faultyLEFT PACK INOPERATIVE LIGHT. REPLACED LT PACK ACM IAW AMM 21-51-03. OPERATIONS & LEAK CHECKS GOOD.SDR UIEA2016052100342Connector · dirtyRIGHT ENG BLEED OFF & RT PACK OFF, EICAS MSG INTERMITTENT DURING CLIMB. RAN BITE ON PNEUMATIC CONTROLLER FAULTED FAN AIR MOD VLV. INSPECTED VLV, CLEANED CONNECTOR & CYCLED VLV IAW AMM 36-11-16. PERFORMED BITE AGAIN, ALL CHECKED NORMAL.SDR UIEA2016051900339Shutoff Valve · malfunctionedRIGHT ENG BLEED OVERHEAT ADVISORY MSG AFTER TAKEOFF, CLEARED IAW QRH PROCEDURE. TROUBLE SHOT IAW FIM 36-10 TREE 835, FOUND HPSOV BAD. R & R HPSOV IAW AMM 36-11-07. DRY MOTORED ENG LEAK CHECKS GOOD.