N824UA
Service difficulty reports · 128
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N824UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N824UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2023011800141Fitting · damagedRH MLG DOOR ACT FITTING REPAIRED AREA. CREATE DIP FOR PLANNING PURPOSES ONLY. 32,170 TOTAL ACFT FC BUT BEFORE 32,200 TOTAL ACFT FC FOR THE NR 9294007. ECRA 5330-07042 PART 3 PERM RPR INSTRUCTIONS. WRK ACMP ON HAECO IAW ECRA 5330-07042 PART 1.3. AT THE RPAIREDSDR CALA2023011800140Fitting · damagedRIGHT MLG DOOR AFT ACT FITTING RPR, FOR THE ECRA 5330-07043 PART 3 PERM RPR INSTRUCTIONS. IAW ECRA 5330-07043 PART 1.3. REF LP 3596240 DIP CREATED AT THE RPR AREA OF THE RH MLG DOOR ACT FITTING, PLANNING TO CONTACT EG AFTER 15NOV2023 BUT BEFORE CARRY APPROVED SDR CALA2022022800525None · noneSYS 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. - BRAKES ECAM BRK SYS 2 FAULT ON TO ROLL. REJECTED LESS THAN 30KIAS. RAN QRHRESET. CHECKED GOOD CREW ACCOMPLISHED QRH RESET AND BRAKES SYSTEM 2 FAULT MESSAGE CLEARED. BRAKING AND STEERING NORMAL AFTER RESET. NO HITSDR CALA2020100701159Fuel Cap · missingPDA 2 FUELER REPORTED CAP MISSING. REPLACED CAP AND ATTACHED LANYARD.SDR CALA2019071301183Pressure Panel · crackedWHILE AT DLH DURING C-2 CHECK, HOLE CRACKS WERE DISCOVERED DURING ACCOMPLISHMENT OF EA5330-05216. OUTSIDE OF CUTOUT AREA AT HOLES 1, 2 & 4 ON LT FRAME 35/36 ACCOMPLISHED REPAIR OF ALL HOLES IAW EC/RA 5331-02412 TO LT FR35-36 PRESSURE PANEL HOLE CRACKS. ACCOMPLSDR CALA2019070201106Stop Fitting · crackedRT FR 66 #1 DOOR STOP FITTING I/B LOWER FASTENER HOLE HAS CRACK INDICATION. REF N/R 9620197. REAMED RT FR66 #1 DOOR STOP FTG I/B LOWER HOLE TO .280". ROTO PROBE PERFORMED, NO CRACK INDICATION. PERFORMED REPAIR IAW SRM 53-41-12-300-010, SRM 51-44-11-001, NTM 51SDR CALA2019070201105Stop Fitting · crackedLT FR 68 #1 DOOR STOP FITTING I/B LOWER FASTENER HOLE HAS CRACK INDICATION. REF N/R 9620198. REAMED LT FR68 #1 DOOR STOP FTG I/B LOWER HOLE TO .280". ROTO PROBE PERFORMED, NO CRACK INDICATION. PERFORMED REPAIR IAW SRM 53-41-300-010, SRM 51-44-11-001, NTM 51-10SDR CALA2019070201107Door Frame · crackedLT FR 66 #1 DOOR STOP FITTING I/B LOWER FASTENER HOLE HAS CRACK INDICATION, REF N/R 9620196. REAMED LT FR66 #1 DOOR STOP FTG I/B LOWER HOLE TO .280". ROTO PROBE PERFORMED, NO CRACK INDICATION. PERFORMED REPAIR IAW SRM 53-41-12-300-010, SRM 51-44-11-001, NTM 51SDR CALA2019063001103Hook · worn(SUPPORT TASK) R2 DOOR HANDLE GEAR BOX HOOK WORN. REFER TO AAR N /R: 9620410. REMOVED AND REPLACED R-2 DOOR HANDLE GEAR BOX HOOK IAW CMM 52-13-15.SDR CALA2019062401058Support Frame · corrodedUPON REMOVAL OF SHEAR PLATE TO ACCOMP LISH EA 5346-01001 REV. B OP 003, FOUND SUPPORT FRAME THAT ATTACHES TO BE CORRODED. REMOVED AND REPLACED CORRODED SUPPORT FOR SHEAR PLATE AT FR 69-7 0 R/H IAW SRM 51-72-11-911-001. APPLIED SURFACE PROTECTION IAW ER 5100R0SDR CALA2019062401057Lanyard · unsecureL2 DOOR SLIDE GIRT BAR LANYARD NOT SECURED CORRECTLY. PROPERLY SECURED L2 DOOR SLIDE GIRT BAR LANYARD IAW A319 AMM 25- 62-44-400-006-A SUBTASK 25-62-44-420-064-A.SDR CALA2019062401055Cable · misroutedL2 DOOR SLIDE CABLE ROUTED INCORRECTLY. PROPERLY ROUTED L2 DOOR SLIDE CABLE IAW AMM 25-62-44-400-00 6-A, SUBTASK 25-62-44-560-051-A.SDR CALA2019062401053Pin · unsecureR1 DOOR SLIDE PARACHUTE PIN NOT TIED CORRECTLY. PROPERLY TIED THE PARACHUTE PIN ON R1 DOOR SLIDE IAW AMM 25-62- 44-400-802-A, SUBTASK 25-62-44-420-066-A.SDR CALA2019062401052Lanyard · unsecureR1 DOOR SLIDE GIRT BAR LANYARD NOT SECURED CORRECTLY. PROPERLY SECURED THE R1 DOOR SLIDE GIRT BAR LANYARD IAW AMM 25-6 2-44-400-802-A, SUBTASK 25-62-44-420-066-A.SDR CALA2019062201045Stringer · corrodedON REMOVAL OF SUPPORT FRAME, FOUND STRINGER SECTION CORRODED AT STR 24 FR 70R. A CORROSION RESULTED IN 100% MATERIAL LOSS OF STRINGER SECTION @ S TR 24 FR70R. REMOVED PART AND MATCHDRILLED, DEBURRED, AND INSTAL LED NEW STRINGER SECTION @ STR 24 FR70R. APPLIESDR CALA2017061901891Floor Support · gougedGOUGED FLOOR SUPPORT +Y254 FRAME 70. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11-911-001.SDR CALA2017061901890Seat Track · corrodedCORROSION ON SEAT TRACK +Y1292 LT SIDE, BETWEEN FRAMES 62 AND 63. BLENDED CORROSION IAW SRM 51-73-00, FIG 00101. REMOVED .040, MAX ALLOWED .028, FOUND TO BE OUT OF LIMITS IAW SRM 53-41-15-283-001, FIG 10101, SHT 1. REMOVED AND REPLACED THE SEAT TRACK IAW SSDR CALA2017061601837Floor Support · corrodedCORROSION ON THE FLOOR SUPPORT -Y765, FRAME 68. REMOVED & REPLACED THE FLOOR SUPPORT FRAMES 68 - 70 IAW SRM 51-72-11-911-001. RESTORED SURFACE PROTECTION ON THE FLOOR SUPPORT IAW SRM 51-75-12-911-001.SDR CALA2017061601836Floorbeam · corrodedCORROSION ON THE AFT FLOORBEAM -Y1292 AT FRAME 68, REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53 -00-14-283-002, FIG 10102, SHEET 1. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-72-11, PAGE 1.SDR CALA2017020300258Light · malfunctionedUNABLE TO SHUT OFF EMERGENCY EXIT LIGHTS.SDR CALA2016071195558Controller · faultedCABIN PRESSURE CONTROL 1 AND 2 FAULTED, UNABLE TO PRESSURIZE, CABIN PRESSURE CONTROLLERS 1 AND 2 AND OUTFLOW VALVE FAULTED BEFORE RESET. NO FAULTS NOTED REST OF TESTS.SDR CALA2016031195211Battery · faultedEPSU 33-51-38 BATTERY, EMER RT FAULTS ON CIDS DISPLAY DURING TEST. R & R & REINSTALLED BATTERY, FAULT CLEARED, TEST PASSED.SDR CALA2015110394771Connector · not seatedEMERGENCY LIGHT TEST FAILED ON 2 SERVICE. RESEATED CONNECTOR ON RT EMER LIGHT POWER SUPPLY IAW AMM 33-51-38. EMER LIGHT TEST PASSED.SDR CALA2015081194192Wire · brokenSEAT EMERGENCY EXIT LIGHT AT SEAT 22 ABC INOPERATIVE. FOUND BROKEN WIRE. REPAIRED WIRE. OPERATIONS CHECKED NORMAL.SDR CALA2014102392556Fairing · looseAIRFRAME VIBRATION ONCE AIRBORNE, EMER DECLARED, RETURNED. SECURED & APPLIED TAPE TO FILLET FAIRING ON LT SIDE OF FUSELAGE. COMPLETED INSPECTION OF FUSELAGE, NO DEFECTS FOUND.SDR CALA2014061691281Slat · lockedFLIGHT CONTROL SLATS LOCKED. WING TIP BREAKER ON SLAT SYS 2 FAULT CYCLED CB & PERFORMED BITE CHECK. NO FAULTS FOUND, NO MSGS. OPERATIONS CHECKED WITH CREW PRESENT. OPERATIONS CHECKED GOOD IAW AMM 27-51-00.SDR CALA2014010990115Light · inoperativeSEAT EMERGENCY EXIT LIGHT ON SEAT 29C IS INOPERATIVE. REPLACED SEAT MOUNTED EMERGENCY LIGHT AT SEAT 29C IAW AMM 33-51-18, OPERATIONS CHECKED GOOD.SDR CALA2013123094028Slide · defectiveDOOR SLIDE PRESS GAUGE DOOR 1R NOT VISIBLE. R & R DOOR R1 ESCAPE SLIDE IAW AMM TASKS 25-62-44-00-002-A & 25-62-44-400-006-A.SDR CALA2013111492941Panel · unsecureAFT PIT FLOOR HAS A DEFECT THAT NEEDS CLARIFICATION. SECURED SIDE WALL PANEL AFT PIT. NO DEFECTS NOTED TO FLOOR.SDR CALA2013092391363Computer · faultyAUTO FLIGHT YAW DAMPENER STATUS MESSAGE. TROUBLE SHOT YAW DAMPER 1 MSG. NO ASSOCIATED CFDS MSGS. PERFORMED GROUND SCAN OF THE AFS. TEST FAULTED FAC 1. REPLACED FAC 1 IAW MM, OPERATIONS TEST OF THE AFS FAC 1 TEST PASSED.SDR CALA2013082090599Computer · faultyCREW REPORTED EXCESSIVE ACFT PITCH UP. AFTER TAKEOFF ACFT NEEDED FWD STICK PRESSURE. AT CRUISE SPEED CHANGES RESULTED IN LOSS OR GAIN OF ALTITUDE DUE TO SLOW TRIM RESPONSE. NOTED PITCH UP WAS MORE THAN 2.5 DEGREES PER MIN. AIRMAN SHOWS CFDS MSG "ELAC2 COM SDR UALA2013053003773Hydraulic Line · rupturedGREEN HYD 0 QTY. FOUND RUPTURED BRAKE HYD FLEX LINE AT TOP OF RT MAIN GEAR, REPLACED REF IPC 32-11-12-04F, ACCOMPLISHED LEAK CHECK OF LINE NO LEAKS NOTED, SERVICE GREEN SYS TO FULL. ACCOMPLISHED AMM 29-00-00-280-006-A-0 1 FOR A POSSIBLE CAVITATION OF ENGINESDR UALA2013041802697Computer · faultyFUEL TEMP INDICATION; LEFT INBOARD INOP ON FUEL SYSTEM ECAM PAGE - FUEL COMPLIED WITH MEL. -RDF-P :CFDS MSG FUEL QUANTITY FQIC 3QT MESSAGE ON PFR. RESET FQI CH2 CB AND INDICATION RETURNS TO NORMAL FOR APPROX 2 MINUTES AND THEN GOES TO XX AGAIN. SUSPECT FQIC.SDR UALA2013041502548Warning System · activatedFUEL TEMP INDICATION; RIGHT OUTBOARD INOP ON FUEL SYSTEM ECAM PAGE - FUEL.SDR UALA2013041002409Battery · no testEMERGENCY LIGHTS FAIL SERVICE TEST, DISPLAYS EPSU BATTERY AFT MESSAGE. REPLACED EPSU BATTERY AT AFT EPSU 13WL, OPS NORMAL.SDR UALA2013040502293Amu · inoperativeFIRST OFFICER`S OXYGEN MASK MICROPHONE IS INOPERATIVE. O2 MASK NO HELP, O2 BOX NO HELP, ORIGINAL INSTALLED. REMOVED AND REPLACED AMU, OPS CHECK OKAY.SDR UALA2013030401291Door · obstructedCANNOT ARM 2L. LEVER IS UP AND CANNOT BE MOVED DOWN. CLEANED DEBRIS FROM DOOR, OPS NORMAL.SDR UALA2012110506359Controller · inoperativeRIGHT WINDSHIELD DISPLAYED ON UPPER ECAM SCREEN. - ANTI ICE. REPLACED NR 2 WHC OP CHECKS GOOD.SDR UALA2012101205819Panel · damagedINTERIM REPAIRS TO AFT LAV PANEL COMPLETED PER ECRA 534101022. WELDING REPAIR LOOKS GOOD AND MEETS ECRA 534101022. ACP NDT PER 51-10-21 INTERNAL AND EXTERNAL INSPECTION FOUND NO CRACKS. ACP INTERNAL HFEC AND OPEN HOLE INSPECTIONS NO CRACKS FOUND.SDR UALA2012100405633Pin · damaged'ENG FIRE EXTING-SQUIB' LIGHT OF 'AGENT 1' PUSHBUTTON SWITCH IS OFF DURING 'LOOP-SQUIB TEST'. ENG 2 SQUIB LIGHT WON'T TEST. ACCMP'D CHECK PER MEL. PANEL IN A/C LOB. PARTS: 565-9002 MR26123 - PANEL. REPLACED PIN 2 OF 5WE2A, FOUND DAMAGED. OPS CKD OKAY.SDR UALA2012082904866Check Valve · leakingFUEL LEAKING FROM RT WING SURGE VENT. REPLACED FUEL PUMP CHECK VALVE IAW MM.SDR UALA2012082904865Control Unit · failedEXTERNAL POWER EGIU CIRCUIT BREAKER TRIPPED. REPLACED EGCIU1 PER MM, CHECKED GOOD.SDR UALA2012032301876Wire · pulledCLEANING FOREMAN REPORTS ON WALK THRU ELECTRICAL WIRES HANGING DOWN BELOW SEAT 32C. FOUND WIRE PULLED OUT OF CONNECTOR FOR THE EEL LIGHT ON THE SIDE OF SEAT 32C. TURNED ON THE EMER EXIT LIGHT SWITCH-ALL OTHER LIGHTS WORKING NORMALLY. TAPED AND SECURED WIRINSDR UALA2012032701937Wire · unsecureCLEANING FOREMAN REPORTS ON WALK THRU ELECTRICAL WIRES HANGING DOWN BELOW SEAT 32C. TURNED ON THE EMER EXIT LIGHT SWITCH-ALL OTHER LIGHTS WORKING NORMALLY. TAPED AND SECURED WIRING BELOW SEAT 32C. PLACED PLACARD ADJACENT TO THE EMER EXIT LIGHT SWITCH IN THE SDR UALA2012012000441Floorboard · defectiveGALLEY FLOOR SPONGY AT DOOR 2R. DAMAGE IS INBOARD EDGE 5 X 5 AND 10X2 NON PERFORATION. OK TO CF PER SRM. PERM REPAIR WITHIN 350FH. PANEL NUMBER 262FF PCN#110-4657. CURRENT PTT IS 45211:11. TOTAL AREA IS 45 SQ IN., SRM ALLOWS 69.75, 7.087 X 9.843". REPLASDR UALA2011111806321Oxygen Mask · faultyON CAPTS O2 MASK THE RED TEST BUTTON MIGHT BE MISSING TOP. REPLACED MASK, OPS GOOD PER SUBTASK.SDR UALA2011111606277Ram Air Turb · deployedECAM CAUTION MESSAGE - RAT FAULT MESSAGE INOP - HYD. CREW COMMENTS: RAT IS DEPLOYED. RAT WAS DEPLOYED ON THE GROUND. STOWED RAT PER MM.SDR UALA2011102505791Microphone · inoperativeF/O'S OXYGEN MASK MICROPHONE IS INOPERATIVE. REPLACED F/O O2 OXYGEN MASK STOWAGE BOX PER AMM.SDR UALA2011061502955Oxygen Mask · dislodgedMASK FELL SEAT 10B. REPACKED O2 MASK AT SEAT 10B.SDR UALA2011050902248Oxygen Mask · faultyF/O OXY MASK MIC INOP. REPLACED F/O'S O2 MASK, OPS CHECK NORMAL.
Back to N824UA