N8783E
Service difficulty reports · 113
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8783E' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8783E' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2022100302167None · corrodedCORROSION FOUND ON CARGO FLOOR BEAM AT RBL27 BETWEEN FS605-FS621 REPAIRED SEAT RAIL 601R35031-263 AND FLOOR BEAM FITTING 601R35289-4SDR REXA2022100302164Fitting · crackedRH SIDE SIDE WINDSHIELD POST HAS CRACK AT LOWER AFT CLIP RADIUS. REMOVED AND INSTALLED NEW R/H SIDE WINDSHIELD POST AFT FITTING REF CRJ-200 SRM 51-42-21 AND DWG 601R33007 REV -USDR REXA2022100302169None · corrodedFOUND CORROSION ON RBL 9 FLOOR BEAM FLANGE AT FS 559+64 - FS 559+112 REMOVED CORROSION ON FLOOR BEAM AT RBL9 FROM FS 559+16 TO FS 559+80 REF CRJ 200 SRM 51-21-06. FOUND TO BE OUT OF LIMITS REF CRJ 200 SRM 53-00-00 PGS 101-106 AND CRJ 200 SRM 53-51-43. REPLACEDSDR REXA2022100302168Strap · corrodedCORROSION ON FLOOR STRAP BETWEEN RBL9 AND RBL27 AT FS559+48 REMOVED AND REPLACED FLOOR STRAP AT FS559+48 BETWEEN RBL9 & RBL27 WITH NEW P/N: 601R32215-43 REF CRJ200 SRM 51-42-06 DUE TO 100% MATERIAL LOSSSDR REXA2022100302166None · corrodedLH PRESSURE FLOOR SILL ANGLE HAS SEVERAL AREAS OF CORROSION AROUND FS 409.00+128 - FS 559.00 REPAIRED PER CRJ253-14480 REV A DATED 09/23/2022.SDR REXA2022100302165Skin · wornRH OUTBD FLAP HAS NUMEROUS SMOKING RIVETS ON UPPER SKIN REPAIRED RH OUTBD FLAP NUMEROUS SMOKING RIVETS ON UPPER SKIN REF EA CRJ257-14441 REV. A DATED: 09/09/2022SDR REXA2022100302163Bracket · wornRIGHT INBOARD FLAP INBD ATTACHMENT BRACKET ON THE INBD HINGE ARM CHAFED FOUND TO BE OUT OF LIMITS IAW CRJ 200 SRM 57-54-00, INSTALLED NEW ATTACHMENT BRACKET P/N: 601R14116-85 CRJ 200 SRM 51-42-06 AND CRJ 200 SRM 51-45-00SDR REXA2022100302162Separator · wornPANEL 422DB HAS BOTH SEPARATORS KNIFE-EDGED REMOVED AND INSTALLED (2) EA NEW SEPARATORS P/N: 601R37138-24 AND -26 ON PANEL 422DB REF CRJ200 SRM 51-42-06SDR REXA2022100302161Separator · wornPANEL 412DB HAS BOTH SEPARATORS KNIFE-EDGED REMOVED AND INSTALLED (2) EA NEW SEPARATORS P/N: 601R37138-25 AND -27 ON PANEL 412DB REF CRJ200 SRM 51-42-06SDR REXA2021090820703Charger · inoperativeEMERGENCY LIGHT SYSTEM IS BURNT OUT FROM ROW 2-6. R/R #2 CHARGER ASSY AND #2 BATTERY PACK IAW AMM 33-51-05 AND 33-51-04. OPS TEST INTERIOR AND EXTERIOR EMERGENCY LIGHTS NORMAL.
SDR REXA2019090401283Fuel Line · faultySTRONGFUEL SMELL FROM PACKS WHEN APU IS RUNNING. REMOVED AND REPLACED APU FUEL LIKE TUBE ASSY AND RIGHT AND LEFT WATER SEPARATOR COALESCER BAG IAW CMM 49-26-43 AND AMM 21-51-13 OPS CK GOOD AT THIS TIME.SDR REXA2019061710841Retainer · crackedSEAL RETAINER IS CRACKED ON LEFT HAND OVERWING ESCAPE DOOR.SDR REXA2019060600838Support Angle · crackedRH ACM RACK LWR PRSOV SUPPORT ANGLE CRACKED. REMOVED CRACKED SUPPORT ANGLE AND INSTALLED NEW ANGLE IAW SRM 51-42-06SDR REXA2019060600836Beam · chafedLH IB FLAP OB VANE ACTUATOR BEAM CHAFED UNDER ROLLER. LH I/B FLAP O/B VANE ACTUATOR BEAM REPAIRED IAW REO 601R-57-52-1979 OPS/CLEARANCE CHECK GOOD IAW CRJ 200 AMM 27-54-15-820-801 AND 27-54-00-710-801 AAR AP 453SDR REXA2019061360834Beam · chafedRH IB FLAP IB VANE ACTUATOR BEAM CHAFED UNDER ROLLER. RH I/B FLAP I/B VANE ACTUATOR BEAM REPAIRED IAW BOMBARDIER REO 601R-57-52-1979 OPS/CLEARANCE CHECK GOOD IAW CRJ 200 AMM 27-54-15-820-801 AND 27-54-00-710-801.SDR REXA2019061360829Doubler · crackedAC GROUND POWER DOOR 122BR LANDING, FWD EDGE IS MISSING. REPAIRED AC GROUND POWER DOOR 122BR LANDING, FWD EDGE I.A.W. BOMBARDIER REO 601R53-11-569SDR REXA2019061350835Beam · chafedRH IB FLAP MID VANE ACTUATOR BEAM CHAFED UNDER ROLLER. REPAIRED CHAFE ON RH I/B FLAP MID VANE ACTUATOR BEAM UNDER ROLLER IAW BOMBARDIER REO 601R-57-52-1979 OPS/CLEARANCE CHECK GOOD IAW CRJ 200 AMM 27-54-15-820-801 AND 27-54-00-710-801 AAR SM 107SDR REXA2019061350833Beam · chafedRH IB FLAP OB VANE ACTUATOR BEAM CHAFED UNDER ROLLER. REPAIRED CHAFE UNDER ROLLER ON RH O/B VANE ACTUATOR BEAM ON I/B FLAP RH IAW BOMBARDIER REO 601R-57-52-1979 OPS/CLEARANCE CHECK GOOD IAW CRJ 200 AMM 27-54-15-820-801 AND 27-54-00-710-801SDR REXA2019061350832Beam · chafedLH IB FLAP MID VANE ACTUATOR BEAM CHAFED UNDER ROLLER. REPAIRED CHAFE ON LH I/B FLAP MID VANE ACTUATOR BEAM UNDER ROLLER IAW REO 601R-57-52-1979 OPS/CLEARANCE CHECK GOOD IAW CRJ 200 AMM 27-54-15-820-801 AND 27-54-00-710-801 AAR SM 107SDR REXA2019061350831Beam · chafedLH IB FLAP IB VANE ACTUATOR BEAM CHAFED UNDER ROLLER. REPAIRED CHAFE UNDER ROLLER ON LH I/B FLAP VANE ACTUATOR BEAM IAW BOMBARDIER REO 601R-57-52-1979 OPS/CLEARANCE CHECK GOOD IAW CRJ 200 AMM 27-54-15-820-801 AND 27-54-00-710-801SDR REXA2019061340840Structure · crackedPAX DOOR UPPER EDGE MEMBER IS CRACKED AT THE AFT SIDE, UNDER TOP STEP 832ET. REPAIRED PAX DOOR UPPER EDGE MEMBER IAW REO 601R-52-11-279SDR REXA2019061340839Drag Angle · crackedPAX DOOR AFT DRAG ANGLE CRACKED - REPAIRED PAX DOOR AFT DRAG ANGLE IAW REO 601R-52-11-513SDR REXA201906130824Seal · wornR/H UPPER CORE COWL T/E IS CHAFED, REMOVED OLD AND INSTALLED NEW CLOSURE RING IAW BOMBARDIER CMM 71-12-01.SDR REXA2019061310830Plate · chafedFLAP FAIRING 692BB HAS CHAFFED GUIDE PLATE. REMOVED/INSTALLED NEW GUIDE PLATE ON PANEL 692BB IAW CRJ 200 SRM 51-42-06SDR REXA2019061310825Angle · crackedPYLON PANEL 422BT SEAL RETAINER IS CRACKED. REMOVED & REPLACED SEAL RETAINER IAW CMM 20-42-06.SDR REXA2019061300837Angle · crackedWHILE PERFORMING INSPECTION OF PRESSURE FLOOR SKIN, NOTED ANGLE CRACKED AF FS484, LBL27. REMOVED/REPLACED CLIP ANGLE AT FS 484 LBL 27 IAW CRJ 200 SRM 51-42-06 AND 51-42-21SDR REXA2019061300827Retainer · crackedPYLON ACCESS PANEL 422DB SEAL RETAINER IS CRACKED. REMOVED AND REPLACED SEAL RETAINER IAW CRJ-200 SRM-51--42-06.SDR REXA2019061300826Retainer · crackedPYLON ACCESS PANEL 422DB SEAL RETAINER IS CRACKED. REMOVED AND REPLACED SEAL RETAINER IAW SRM-51-42-06.SDR REXA2019061300823Angle · crackedWHILE PERFORMING INSPECTION OF PRESSURE FLOOR SKIN, NOTED ANGLE CRACKED AF FS484, LBL27 - REMOVED/REPLACED CLIP ANGLE AT FS 484 LBL 27 IAW CRJ 200 SRM 51-42-06 AND 51-42-21.SDR REXA2019061329828Angle · crackedWHILE PERFORMING INSPECTION OF PRESSURE FLOOR SKIN, NOTED ANGLE AT FS484, RBL27 CRACKED.
REMOVED & REPLACED CLIP ANGLE AT FS484 RBL27 IAW CRJ 200 SRM 51-42-21.SDR REXA2019061370821Strap · corrodedWHILE ACCESSING INSPECTION AREA, NOTED FLOOR SUPPORT STRAP AT FS559.00 LBL36 IS CORRODED. REMOVED AND REPLACED FLOOR SUPPORT STRAP @ 559 LBL 36 IAW CRJ200 SRM 51-42-06SDR REXA2019061370820Strap · corrodedWHILE ACCESSING INSPECTION AREA, NOTED FLOOR SUPPORT STRAP AT FS559.00 RBL36 IS CORRODED. REMOVED AND REPLACED FLOOR SUPPORT STRAP AT BS 559, RBL 36 IAW SRM 51-42-06.SDR REXA2019052600819Rub Strip · chafedPYLON ACCESS PANEL 422DB FIRE SHIELDS ARE CHAFFED. REMOVED AND REPLACED FIRE SHIELDS AND RUBSTRIPS IAW CRJ200 SRM 51-42-13SDR REXA2019061360818Rub Strip · chafedPYLON ACCESS PANEL 412DB FIRE SHIELDS ARE CHAFED. REMOVED AND REPLACED FIRESHIELDS AND RUBSTRIPS IAW CRJ200 SRM 51-42-13SDR REXA2019613050822Retainer · crackedPYLON ACCESS PANEL 412BT HAS CRACKED SEAL RETAINER. REMOVED AND REPLACED SEAL RETAINER IAW CRJ200 SRM 51-42-06SDR REXA2019061340817Intercostal · crackedINTERCOSTAL JUST AFT OF EXTERNAL POWER PLUG APPEARS TO BE CRACKED AT TOOLING HOLE, LOCATED JUST I/B AND AFT OF ACCESS DOOR 122BR OPENING. - EDGE BLENDED CRACKED AREA IN AFT INTERCOSTAL AT POWER PLUG IAW CRJ 200 SRM T.R 51-44 FOUND TO BE WITHIN LIMITS IAW CRJ 2SDR REXA2019041700465Battery Pack · inoperativeAFT FLOOR EMERGENCY LIGHTS INOP. REMOVED AND REPLACED PS4LF BATTERY AND CHARGER IAW AMM 33-51-05. OPS CHECK GOOD.SDR REXA2019010600011Wire Harness · damagedSUPPLEMENTAL INFORMATION. EMERGENCY FLOOR LIGHTING HAS 3 SECTIONS INOP FROM SEATS 6-8. FOUND EMERGENCY LIGHT CABLE ASSEMBLY IN FLOOR STRIP WITH BREAKS IN WIRES. INSTALLED NEW CABLE ASSY IAW AMM 33-51-01-400-808. REINSTALLED 3 FLOOR LIGHT SECTIONS IAW AMM 33-51SDR REXA2019010200001Connector · looseINSIDE EMERGENCY FLOOR LIGHTS CENTER SECTION IS INOPERATIVE. FOUND AND SECURED LOOSE CONNECTION AT SEAT 5C, D LOCATION IAW AMM 33-51-00. OPS CHECK GOOD.SDR REXA2018091400857Light · looseEMERGENCY FLOOR LIGHTNING INOP AT EMERGENCY EXIT ROW. FOUND EMER FLOOR LIGHT LOOSE. RESECURED IAW AMM 33-51-01. OP CHECK GOOD, OK FOR SVC.SDR REXA2018080620673Smoke Detector · false indicationHAD A SMOKE TOLIET CAUTION MESSAGE AND ALARM WENT IFF, FA WENT TO THE LAVATORY TO CHECK, NO SMOKE OR FUMES WERE FOUND. PERFORMED AN OPERATIONAL TEST OF AFT LAVATORY SMOKE DETECTOR IAW AMM 26-50-00, OPS TESTED GOOD.SDR REXA2018070300601Post · crackedDURING COMPLIANCE OF T/C 53-160-635, NOTED VERT POST LBL 27.00 HAS A CRACK ON LWR IB FLANGE EXTENDING FROM EDGE UP TO AND PAST THE 1ST RIVET ENDING APPROX MID POINT BETWEEN 1ST AND 2ND RIVETS. REPAIRED VERT POST LBL 27.00 FS 409+128 IAW REO 601R-53-41-0056. THSDR REXA2018060520435Connector · disconnectedFLOOR EMERGENCY LIGHTS INOPERATIVE. CONNECTED LIGHT AND OPS CHECKED GOOD IAW AMM 33-51-01. NO FURTHER DEFECTS NOTED.SDR REXA2018042760315Light · inoperativeSECTION OF EMERGENCY LIGHTING BY SEAT 8DC WAS FOUND INOPERATIVE. R & R THE EMERGENCY LIGHT IAW AMM 33-51-01. OPS CHECKED GOOD.SDR REXA2018042040300Light · malfunctionedEMERGENCY FLOOR LIGHT IN THE MIDDLE OF THE CABIN IS NOT ILLUMINATING. PERFORMED AN OPS CHECK OF EMERGENCY LIGHTS IAW AMM 33-51-00. OPS CHECKED GOOD.SDR REXA2018040400246Seal · damagedGALLEY DOOR SEAL HAS VENT HOLES MISSING AND VENT HOLES IN WRONG LOCATION BEING BLOCKED IAW AMM 52-41-07. ADDED VENT HOLES AND RELOCATED BLOCKED HOLES IN THE GALLEY DOOR SEAL IAW AMM 52-41-07SDR REXA2017120801231Light · unknownFLOOR LIGHTING STRIP INOP ROWS -7 AND WALL EXIT SIGN IS INOP
PERFORMED OPERATIONAL TEST OF EMERGENCY LIGHT PER CRJ 200 AMM 33-51-00. OPS CHECK GOOD, NO OTHER DEFECTS NOTED AT THIS TIME.SDR REXA2017111301162Battery Pack · inoperativeDURING WAKE UP, CO PILOT EMERGENCY FLASHLIGHT WAS FOUND NOT BLINKING. BATTERY NOT CHARGING. REMOVED AND REPLACED THE BATTERY IN THE FLASHLIGHT IAW 25-61-00. OPS CHECKED GOOD.SDR REXA2017080400857Smoke Goggles · brokenCAPTAIN`S SMOKE GOGGLES BROKEN. REMOVED AND REPLACED THE SMOKE GOGGLES IAW AMM 35-11-12SDR REXA2017071700794Light · inoperativeFLOOR LEVEL EXIT LIGHT NEXT TO LEFT EMERGENCY EXIT DOOR INOP. REMOVED AND REPLACED EXIT LIGHT IAW AMM 33-51-10.