N880AA
Service difficulty reports not matched to an aircraft · 61
They name N880AA, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N880AA' AND registry_match IS NULL ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N880AA' AND registry_match IS NULL ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20011719Stringer · corrodedTUL - FOUND STRINGER 24L DENTED AT STATION 460. CUT AND REMOVED DAMAGED SECTION OF STRINGER. SPLICED IN NEW SECTION OF STRINGER PER SRM 53-10-3. (M)SDR AALA20011720Skin · gougedTUL - FOUND GOUGE IN SKIN STATION 460 STRINGER 24L. CUTOUT DAMAGED AREA OF SKIN AND INSTALLED DOUBLER REPAIR PER SRM 53-30-3. (M)SDR AALA20011718Web · crackedTUL - FOUND VERTICAL WEB OF RIGHT LOWER TORQUE BOX CRACKED APPROX STATION 1233 UPPER LIGHTENING HOLE. INSTALLED DOUBLER OVER DAMAGED AREA (AFTER ROUTING OUT CRACK) PER SRM 51-40-2. (M)SDR AALA20010492Battery Pack · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT L1 DOOR DIM. REPLACED EMERGENCY EXIT LGIHT BATTERY PACK AND CHARGER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010497Lamp · inoperativeDFW - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHT AT R2 DOOR DIM. REPLACED EMERGENCY EXIT LIGHT AT R2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010140Light · inoperativeMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT ROW 6 THROUGH 21 INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20001783Skin · dentedTUL - FOUND FORWARD ENTRY DOOR CUT OUT FRAME DENTED AT LOWER HINGE. INSTALLED REPAIR DOUBLER AT LOWER HINGE IAW SB 727-0198. (M)SDR AALA20001768Stringer · corrodedTUL - FOUND CORROSION 3 INCHES BY 2 INCHES, STRINGER 25R STATION 1148. REMOVED DAMAGE AREA OF STRINGER REPAIR PER SRM 55-10-3 FIG 1. 9M)SDR AALA20001763Skin · corrodedTUL - FUSELAGE SKIN CORROSION AROUND RIVETS IN AFT CARGO STATION 1010-1020, STRINGER 28L-29R. REMOVED SECTION OF CORRODED SKIN AND INSTALLED DOUBLER AND PER RM 53-30-3 FIG 3A. (M)SDR AALA20001754Beam · corrodedTUL - FOUND LEFT HORIZ STABILIZER TRAILING EDGE BEAM HAD CORROSION AT STATION 160. REMOVED CORROSION AND INSTALLED DOUBLER PER ESO 11697, DATED 10/20/00. (M)SDR AALA20001762Stringer · corrodedTUL - FOUND CORROSION ON BOTTOM OF STRINGER 30 AT STATION 1013. REMOVED PREVIOUS STRINGER SECTION AND INSTALLED NEW SECTION, 11 INCHES, PER SRM 53-10-3. (M)SDR AALA20001761Skin · corrodedTUL - FOUND CORROSION OUTBOARD OF STRINGER 27L ON SKIN. REMOVED CORROSION BY REMOVING DAMAGED SKIN AND INSTALLED DOUBLER PER SRM 53-30-3 FIG 1. (M)SDR AALA20001253Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, AFT STAIRWAY EMERGENCY LIGHT INOPERATIVE. REPLACED AFT STAIRWAY EMERGENCY LIGHT ASSEMBLY. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20000940Connector · damagedMIA - DURING OVERNIGHT MAINTENANCE, AFT EMERGENCY EXIT FLOOR PATH LIGHTING INOPERATIVE. REPLACED CONNECTOR ON AFT EMERGENCY EXIT FLOOR PATH LIGHTING SYSTEM. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA990851Connector · brokenMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING AFT CABIN INOPERATIVE. REPAIRED CONNECTOR ON EMERGENCY EXIT FLOOR PATH LIGHTING. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA990778Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT STRIP IN FIRST CLASS BROKEN. REPAIRED FLAT WIRE ON EMERGENCY EXIT FLOOR PATH LIGHT STRIP IN FIRST CLASS. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA982065Strap · corrodedTUL - FOUND CORROSION ON HORIZ STAB REAR UPPER SRM FAIL/SAFE STRAP RIGHT SIDE. REPAIRED PER ESO 11697, DATED 10/15/98. (M)SDR AALA982064Skin · damagedTUL - DEEP LIGHTNING BURN ON HORIZ STAB (LT) REAR SPAR AND SKIN. BLENDED SPAR AND REPAIRED PER SRM 55-10-3. (M)SDR AALA982063Spar · corrodedTUL - HORIZ STABILIZER FRONT SPAR CENTER SECTION RIGHT UPPER 'A' FRAME MOUNT LUGS AND LOWER 'A' FRAME MOUNT LUGS CORRODED. REPAIRED PER ESO 11697 DATED 10/15/98. (M)SDR AALA982062Spar · corrodedTUL - HORIZ STABILIZER FRONT SPAR CENTER SECTION LEFT UPPER AND LEFT LOWER 'A' FRAME ATTACH LUGS CORRODED. REPAIRED PER ESO 11697, DATED 10/15/98. (M)SDR AALA982061Casting · corrodedTUL - NOSE LANDING GEAR DRAG BRACE CASTING HAS CORROSION IN BORE AND ON FACE. REPLACED DRAG BRACE CASTING WITH NEW PART. (M)SDR AALA982060Stringer · corrodedTUL - FOUND 28R STRINGER FORWARD OF STATION 690 FOUND TO BE CORRODED. FABRICATED NEW STRINGER SPLICE EXTENDED TO PICK UP SAME NUMBER OF FASTENERS PAST DAMAGE CUTOUT PER ESO 11697, DATED 10/21/98. (M)SDR AALA982059Stringer · crackedTUL - FOUND STRINGER AFT OF VENT TOP OF TANK CRACKED AT STATION 686.50. INSTALLED REPAIR PER BOEING S/B 727-57-A155. (M)SDR AALA982058Angle · corrodedTUL - FOUND STATION 340-344 RIGHT SKATE ANGLE HAS CORROSION, FOUND UNDER LEVELING COMPOUND WHICH WAS REMOVED TO ACCOMPLISH WORK ON E58 NR 2736701. REMOVAL OF CORROSION WAS BEYOND LIMITS, INSTALLED 12.75 INCH LONG 'L' ANGLE REPAIR PER ESO 11697, DATED 14 OCT 9SDR AALA982057Skin · corrodedTUL - FOUND LOWER WING SKIN CORRODED ABOVE RIGHT PRIMARY HEAT EXCHANGER STATION 834 RBL 30. REMOVED CORROSION, REMOVED NECESSARY FASTENERS, CLEANED, TREATED, PREPARED AREA AND INSTALLED DOUBLER PER SRM 57-30-3, SEALED AREA WITH 1422A/B. (M)SDR AALA982056Skin · corrodedTUL - FOUND INNER SKIN CORRODED JUST ABOVE STRINGER 26R, STATION 1148-1150. INSTALLED DOUBLER REPAIR PER SRM 53-30-3. (M)SDR AALA982055Skin · gougedTUL - DEEP GOUGE IN SKIN STRINGER 174. BLENDED AREA AND INSTALLED DOUBLER PER SRM 53-30-3 FIG 4. (M)SDR AALA982054Skin · corrodedTUL - BULGE IN SKIN AT STRINGER 18L. CUT OUT BULGED AREA AND INSTALLED DOUBLER PER SRM 53-30-3 FIG 4. (M)SDR AALA982053Skin · dentedTUL - DENT IN SKIN STATION 1080 STRINGER 19L. CUTOUT DENTED AREA AND INSTALLED DOUBLER PER SRM 53-30-3 FIG 4. (M)SDR AALA982052Skin · gougedTUL - FOUND INNER SURFACE OF SKIN GOUGED STATION 415 BELOW STRINGER 9 LEFT. BLENDED GOUGE AND INSTALLED DOUBLER PER SRM 53-30-1 PAGES 1-8. (M)SDR AALA982051Skin · gougedTUL - FOUND DEEP GOUGE IN FUSE SKIN AT AFT LOWER CORNER OF LEFT AFT GALLEY DOOR CUTOUT. BLENDED AREA AND INSTALLED DOUBLER PER 53-30-3 FIG 4. (M)SDR AALA982050Skin · corrodedTUL - FOUND CORROSION ON FUSELAGE SKIN OUTBOARD SIDE OF STRINGER 28R, STATION 680-690. INSTALLED EXTERNAL DOUBLER PER SRM 53-30-3 .063 2024 PLUS 3, 21 INCHES BY 11 INCHES. (M)SDR AALA982049Skin · corrodedTUL - FOUND CORROSION AROUND LEFT ICE LIGHT STATION 720B-720C BETWEEN STRINGER 16 LEFT AND 19 LEFT. PERFORMED FUSELAGE SKIN REPAIR AT LEFT WING SCANNING LIGHT CUTOUT PER SRM 53-30-3, ALODINED AND PRIMED PER MM 51-20-0. (M)SDR AALA982048Frame · corrodedTUL - FOUND CORROSION ON BELL FRAME AT STATION 375 RIGHT WL 209.1 JUST ABOVE FLOOR LEVEL. CUT OUT DAMAGE INSTALLED TYPICAL FORMED SECTION. REPAIR PER SRM 51-40-3 FIG 1 SHEET 3, L-ANGLE DOUBLER 7075 T-6 .090, 1.375 INCH BY 2 INCH BY 8.75 INCH, 29 HI-LOCKS TOTSDR AALA982046Shear Tie · crackedTUL - BELLFRAME SHEAR TIE CRACKED AND DEFORMED STA 600 ABOVE STRINGER 16R. REPAIRED SHEAR TIE PER SRM 53-10-4 AND SKIN PER 53-30-3. (M)SDR AALA982045Floorbeam · corrodedTUL - FOUND CORROSION FLOORBEAM STATION 1050 LB 10 TO LB 55. REMOVED CORROSION, CUTOUT, BEYOND LIMITS, AREA AND INSTALLED REPAIR PER SRM 53-10-8 PAGE 9A AND 9B. (M)SDR AALA982044Floorbeam · corrodedFOUND CORROSION ON UNDERSIDE BS 1110 FLOORBEAM UPPER CHORD ADJ TO FASTENER COVERED BY GALLEY. INSTALLED FLOORBEAM REPAIR PER SRM 53-10-8 PAGE 9E. (M)SDR AALA982043Stringer · crackedTUL - FOUND STRINGER 15R CRACKED FORWARD OF ICE LIGHT AT STATION 720B PLUS 4 INCHES. REPAIRED CRACKED STRINGER IAW SRM 53-10-3 PAGE 3-4B. (M)SDR AALA982042Stringer · crackedTUL - FOUND STRINGER 5 RT CRACKED IN TWO PLACES UPPER FLANGES WHERE CLIP ATTACHES STATION 344. STOP DRILLED CRACKS AND INSTALLED DOUBLERS PER SRM 53-10-3 PAGE 4C-6. (M)SDR AALA982039Stringer · corrodedTUL - FOUND CORROSION INSIDE STRINGER CHANNEL BETWEEN RIVITS. INSTALLED STRINGER SPLICE SAME AS ORIGINAL MATERIAL PRODUCTION SPLICE EXCEPT EXTENDED THE SAME NR FASTENERS PAST DAMAGE PER ESO 11697 DATED 10/15/98. (M)SDR AALA982038Floorbeam · corrodedTUL - FOUND CORROSION ON FLOORBEAM AT STATION 1070, BL 0 - LBL 22. REMOVED CORRODED UPPER PORTION OF FLOORBEAM AND INSTALLED FLOORBEAM REPAIR PER SRM 53-10-8. (M)SDR AALA982037Stringer · corrodedTUL - FOUND CORROSION ON OUTSIDE OF STRINGER 29L STATION 950A TO 970. REMOVED CORROSION AND INSTALLED .071, 7075-T6 REPAIR STRAP PER ECO 11697 DATED 10-14-98. (M)SDR AALA982047Shear Tie · corrodedTUL - AFT SIDE OF SHEAR TIE IS CORRODED. REPLACED SHEAR TIE STRINGER 28L-29L, STATION 1166. (M)SDR AALA982041Stringer · crackedTUL - FOUND CRACK AT END OF STRINGER LAST RIVIT. CUT OUT BAD SECTION OF STRINGER AND SPLICED IN NEW SECTION PER SRM 53-10-3 FIG 5 ESO 11697. (M)SDR AALA982040Web · corrodedTUL - FOUND STATION 351 HAS CORROSION AROUND SEVERAL FASTENERS AT LOWER END OF WEB, FORWARD SIDE. REPAIRED WEB IAW ESO 11697 AND SRM 53-10-9. ENGINEER APPROVED ACCEPTABLE TO NT TRIM OUT BLEND AREA. (M)SDR AALA981965Frame · dentedTUL - BELLFRAME DENTED STATION 520 TOP SIDE INTO RADIUS, WEB STRINGER 22 AREA. REMOVED DAMAGED AREA AND INSTALLED REPAIR, SRM 51-40-3 .050 7075-T6, REPAIR MATERILA AND .1875 FLUSH AND PAN 'D' RIVETS. (M)SDR AALA981966Frame · dentedTUL - BELLFRAME DENTED TOPSIDE FORWARD RADIUS STATION 660 STRINGER 24R. REMOVED DAMAGE AREA AND INSTALLED REPAIR PER SRM 51-40-3 USING .050, 7075-T6 MATERIAL WITH .1875 BUTTON HEAD AND COUNTERSUNK 'D' RIVETS. (M)SDR AALA981964Frame · dentedTUL - BELLFRAME DENTED TOPSIDE, RADIUS AND INTO WEB STATION 660 STRINGER 22L AREA. REMOVED DAMAGED AREA AND INSTALLED REPAIR PER SRM 51-40-3, USING .050 7075-T6 MATERIAL WITH .1875 BUTTON HEAD AND COUNTERSUNK 'D' RIVETS. (M)SDR AALA981963Frame · dentedTUL - BELLFRAME DENTED TOP SIDE, RADIUS AND INTO WEB STATION 660 STRINGER 20L AREA. REMOVED DAMAGE AND INSTALLED REPAIR PER SRM 51-40-3 USING .050, 7075-T6 MATERIAL WITH .1875 BUTTON HEAD AND COUNTERSUNK 'D' RIVETS. (M)SDR AALA981676Light · inoperativeORD - DURING OVERNIGHT MAINTENANCE, FORWARD EMERGENCY EXIT FLOOR PATH LIGHTING AT ROWS 29 AND 30 INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Back to N880AA