N914WN
Service difficulty reports · 256
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N914WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N914WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021120646630Gusset · crackedGUSSET CRACKED IN FWD CARGO BAY BS 500D STR 19L ; / [01] GUSSET REMOVED IN FORWARD CARGO BAY BTW BS 500D; STR19L IAW SRM 51-40-02-0G-0. THE PART HAS NO ALLOWABLE DAMAGE IN SRM WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PARAG. 9.C.; [02] LOCATED AND SDR SWAA2021120745739Web · crackedAFT CARGO DOOR CUTOUT FWD CLOSE OUT WEB PANEL#142KW HAVE MULTIPLE CRACKS. ; / [01] NO ALLOWABLE DAMAGE FOUND ON SRM; PART REQUIRED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0; PAR.9.C.; [02] VERIFIED PART CAN BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-SDR SWAA2021120644396Skin · crackedFOUND 1 INCH CRACK ON THE HORIZONTAL STABILIZER LOWER IN-SPAR SKIN AT STATION 184.70 RIB; 9 INCHES I/B OF THE REAR SPAR. AREA MARKED. ; LOCATED AT RH HORIZONTAL STAB. / [01] REMOVED ACCESS PANEL 341BZ IAW SRM 51-40-02; [02] REMOVED THE DAMAGE PART AT DISCREPANSDR SWAA2021120644171Frame · corrodedWHILE INSPECTING FOR CORROSION IN ACB; FOUND CRACKED DRILL START ON UNDERSIDE OF FRAME AT BS 947; RBL 20; BELOW RH FLOOR-TO-SIDEWALL SUPPORT (MARKED) ; / [01] AFTER FURTHER EVALUATION FRAME ACB AT BS 947; RBL20 FOUND TO BE OUT LIMIT; CRACK LENGHT 0.500' IAW SRSDR SWAA2021120644150Support · corrodedCORROSION ON ACB LH FLOOR-TO-SIDEWALL SUPPORT; BS 727B+6'; BS 727B+10' AND BS 727B+14'; LBL 22 (ALL MARKED) ; / [01] REMOVED CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT; BS727B+6'; BS 727B+10' AND BS 727B+14'; LBL22. MEASURES BS 727B+14': L=0.700'; W=0.500'; D=SDR SWAA2021120644151Support · corrodedCORROSION ON ACB LH FLOOR-TO-SIDEWALL SUPPORT; BS 727D+10' TO BS 727D+14'; AND BS727D+18'; LBL 22 (ALL MARKED) ; / [01] REMOVED CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT; BS727D+10'; BS 727D+14' AND BS 727D+18' LBL22. MEASURES BS 727D+18': L=0.600'; W=0.450';SDR SWAA2021120644152Support · corrodedCORROSION ON ACB LH FLOOR-TO-SIDEWALL SUPPORT; BS 727D+3' TO BS 727D+7'; LBL 22 (ALL MARKED) ; / [01] REMOVED CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT; BS727D+3'; BS 727D+7'; LBL22. MEASURES BS 727D+7': L=0.800'; W=0.600'; D=0.011'. ORIGINAL THICKNESS 0.040'SDR SWAA2021120644153Support · corrodedCORROSION ON ACB LH FLOOR-TO-SIDEWALL SUPPORT; BS 727E+2' AND BS 727E+6'; LBL 22 (ALL MARKED) ; / [01] REMOVED CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT; BS727E+2'; BS 727E+6'; LBL22. MEASURES BS 727D+6': L=0.750'; W=0.500'; D=0.012'. ORIGINAL THICKNESS 0.040SDR SWAA2021120644157Support · corrodedCORROSION ON ACB RH FLOOR-TO-SIDEWALL SUPPORT, BS 727E+8'; 727E+12; 727E+15 AND 727E+18'; RBL 21. REMOVED CORROSION AND FOUND TO BE OUT LIMITS AT BS.727E+8';L=1.800' W=0.600' D=0.011' ORIGINAL THICKNESS 0.040'REMAINING THICKNESS 0.029 IAW SRM 53-00-53-1A-2 SDR SWAA2021120644162Shield · corrodedCORROSION ON FCB AFT SHIELD; UNDER FASTENER HOLE; BS 500+2' TO 500+6'; RBL 24 (MARKED) ; / [01] DAMANGE FOUND ON FCB FWD SHIELD BS 500-520 RBL 24 WL156 P/N 143A8126-20 FOUND TO BE OUT OF LIMIT IAW SRM PART WILL BE REPAIRED BY REMPLACEMENT IAW SRM 51-10-02-0G-0SDR SWAA2021120644163Support · corrodedCORROSION OF FWD CARGO LT FLOOR-TO-SIDEWALL SUPPORT, BS 440+2'; 440+10' AND 440+14'; BS 500+14'; LBL 25. REMOVED CORROSION, OUT OF LIMITS IAW SRM 53-00-53-1A-2, ALLOWABLE DAMAGE 2, STEP 4.2A. LOCATED AND DRILLED A NEW SIDE WALL SUPPORT ANGLE AND SPLICE ANGLSDR SWAA2021120644164Shield · corrodedCORROSION ON FCB FWD SHIELD; UNDER FASTENER HOLE; BS 420+2'; RBL 24 (MARKED) ; / [01] DAMANGE FOUND ON FCB FWD SHIELD BS 420-440 RBL 24 WL156 P/N 143A8126-22 FOUND TO BE OUT OF LIMIT IAW SRM PART WILL BE REPAIRED BY REMPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9C; SDR SWAA2021120644165Support · corrodedCORROSION ON FCB RH FLOOR-TO-SIDEWALL SUPPORT; BS 500A+6'; 500A+18'; 500B+14'; 500B+18'; 500C+2'; 500C+6'; 500C+14' RBL 24 (ALL MARKED) ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT RBL2; WL156; BODY;STATION:500A+6; 500A+18; 500B+14; 500B+18; 500C+2;SDR SWAA2021120644166Support · corrodedCORROSION ON FCB AFT BULKHEAD-TO-FLOOR SUPPORT; BS 500D; RBL13; LBL 14; LBL 16; LBL 18 AND LBL 22 (ALL MARKED) ; / [01] REMOVED CORROSION ON BULKHEAD TO FLOOR SUPPORT AT BS 500D'; LBL22; WL 156 ; MEASURE L=5'X W=1'X D=0.010' MAX. MAT LOSS IS 0.010'; REMAINING SDR SWAA2021120644170Support · corrodedCORROSION ON ACB RH FLOOR-TO-SIDEWALL SUPPORT; UNDER AFT FASTENER NUTPLATE; BS 947; RBL 21 (MARKED) ; / [01] REMOVED CORROSION ON FLOOR SIDEWALL SUPPORT ACB AT BS 947 RBL 21; REWORKED AREA; L= 1.5' W= 0.800' D= 0.008' ORIGINAL THICKNESS 0.040' REMAINING THICHNSDR SWAA2021120644172Angle · corrodedCORROSION ON ACB AFT BULKHEAD-TO-FLOOR SUPPORT ANGLE UNDERSIDE; BS 947; RBL 18 (MARKED) ; / [01] EVALUATED DAMAGE ON BULKHEAD ANGLE FLOOR SUPPORT ACB AT BS 947 RBL 18 FOUND TO BE OUT LIMIT DUE NOT LIMIT IN SRM PART WILL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-SDR SWAA2021120644154Support · corrodedCORROSION ON ACB LH FLOOR-TO-SIDEWALL SUPPORT; BS 747+7 - 747+18', LBL 22. REMOVED CORROSION. OUT OF LIMITS IAW SRM 53-00-53-1A-2. DISCREPANCY WILL ACCOMPLISHED ON CARD TTG8Q009BFVR.SDR SWAA2021120644159Strap · corrodedCORROSION ON ACB T-STRAP AT BS 767+5'; RBL 10 (MARKED) ; / [01] EVALUATED CORROSION ON T- STRAP; BS 767+5 RBL 1O' FOUND TO BE OUT LIMITS. DUE NO LIMITS IN SRM PART WILL BE; REPAIRABLE BY REPLACEMENT. IAW 51-10-02-0G-0.; [02] VERIFIED CORROSION REMOVAL FOUND TOSDR SWAA2021120644160Shield · corrodedCORROSION OF AFT CARGO FWD SHIELD, BS 767+11'; RBL 21. CORROSION FOUND TO BE OUT OF LIMITS. REMOVED THE FWD SHIELD AT BS 767 TO BS 786 RBL21 IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED SHIELD IAW SRM 51-40-04 DWG 46A0081. INSTALLED ACB FWD SHIELD IAW SRSDR SWAA2021120644161Strap · corrodedCORROSION ON ACB T-STRAP AT BS 887; RBL 10 (MARKED) ; / [01] EVALUATED CORROSION ON T- STRAP; BS 787 RBL 1O' FOUND TO BE OUT LIMITS. DUE NO LIMITS IN SRM PART WILL BE; REPAIRABLE BY REPLACEMENT. IAW 51-10-02-0G-0.; [02] VERIFIED CORROSION REMOVAL FOUND TO BE OSDR SWAA2021120643687Floor Panel · pulledPASSENGER CABIN FLOOR PANEL 241BF HAS FASTENER INSERT PULLED THROUGH AND HAS LAYER SEPARATION WITH LOOSE STRANDS. DUE TO EXTENT OF DAMAGE TO FLOOR PANEL; FABRICATED FLOOR PANEL. INSTALLED INSERTS, CURED INSERTS; APPLIED TAPE TO LOWER SURFACE IAW SRM 53-00-SDR SWAA2021120643688Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 241AF HAS AREAS OF LAYER SEPARATION WITH LOOSE STRANDS. ; / [01] DUE TO EXTENT OF DAMAGE; FABRICATED NEW PANEL USING BMS 4-17 TY 6 LOT# 1473037-1; INSTALLED FASTENERS USING BMS 5-107 CL 1 LOT# AK0DP4051K; CURED INSERTS; APPLIED TAPESDR SWAA2021120643689Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 242BF HAS AREAS OF LAYER SEPARATION WITH LOOSE STRANDS. ; / [01] DUE TO THE EXTENT OF DAMAGE; BEGAN FABRICATION OF NEW PANEL CUT FROM BMS 4-23TY2 LOT#1472890-1; LOCATED AND DRILLED ALL INSERT LOCATIONS IAW SRM 53-00-50-2R-0 PARA 1A(SDR SWAA2021120643690Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 242AF HAS AREAS OF LAYER SEPARATION WITH LOOSE STRANDS. ; / [01] DUE TO THE EXTENT OF DAMAGE; BEGAN FABRICATION OF NEW PANEL CUT FROM BMS 4-23TY2 LOT#1472890-1; LOCATED AND DRILLED ALL INSERT LOCATIONS IAW SRM 53-00-50-2R-0 PARA 1A(SDR SWAA2021120643681Bulkhead · crackedCRACKED LOWER R/H COMPOSITE BULKHEAD AT BS663 RBL39 WL161. MARKED ; / [01] IDENTIFIED MATERIAL OF VAPOR BARRIER WEB IAW SRM 57-10-10-0I-2 FIGURE 1 AND 2; ITEM# 4; TABLE 2<BR><BR>DAMAGE IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 57-10-10-1A-2 PARA 4.D(1)<BR><BR>SDR SWAA2021120643680Panel · missingAFT CARGO COMP. FLOOR PANEL 140AF HAS 3EA MISSING FASTENERS; MARKED ; / [01] FABRICATED NEW ACB FLOOR PANEL 140AF FROM 090 CONOLITE; LOT# 1469728-2 PER AMM 25-52-01-201-801 AND DWG 453A2610; [02] VERIFIED FABRICATION OF NEW ACB FLOOR PANEL 140AF FROM .090 CONOSDR SWAA2021050366990Floor Panel · tornAFT CARGO BIN FWD FLOOR LINER HAS 22' TEAR 1 3/8' FROM AFT EDGE.' / REMOVED & REPLACED AFT CARGO FWD FLOOR PANEL IAW AMM 25-52-10. CL# 77999SDR SWAA2021042967331Liner · crackedAFT CARGO COMPARTMENT FWD LINER HAS 22 INCH CRACK 1 3/8' FROM FWD EDGE ; AFT CARGO COMPARTMENT FWD LINER HAS 22 INCH CRACK 1 3/8' FROM FWD EDGE / REMOVED AND REPLACED AFT CARGO FWD FLOOR PANEL IAW AMM 25-52-10. CL#77999SDR SWAA2021042665419Bulkhead · crackedCENTER CARGO BULKHEAD PANEL AT STA 731 HAS LARGE CRACK. RR CENTER CARGO BULKHEAD AT STA 731 IAW AMM 255218.SDR SWAA2021072910722Threshold · looseFWD ENTRY DOOR FLOOR THRESHOLD AROUND DRAIN ISN'T SECURED / SECURED FWD ENTRY DOOR FLOOR THRESHOLD PER SRM 53-00-50 & AMM 20-50-11SDR SWAA2021072910721Threshold · looseFWD SERVICE DOOR FLOOR THRESHOLD AROUND DRAIN ISN'T SECURED / SECURED FWD SERVICE DOOR FLOOR THRESHOLD PER SRM 53-00-50 & AMM 20-50-11SDR SWAA2020041336372Battery · dischargedCABIN EMERGENCY LIGHTS FAILED CAPACITY CHECK AT LOCATIONS M1669 AND M1672 / R&R EMERGENCY LIGHT BATTERIES AT LOCATIONS M1669 AND M1672 PER MM 33-51-06SDR SWAA2020041336375Slide · out of adjustFWD ENTRY DOOR SLIDE GIRT REQUIRES ADJUSTMENT / ADJUSTED FWD ENTRY DOOR SLIDE GIRT PER AMM 25-66-01.SDR SWAA2020041336376Slide · out of adjustAFT ENTRY DOOR SLIDE GIRT REQUIRES ADJUSTMENT / ADJUSTED AFT ENTRY DOOR SLIDE GIRT PER AMM 25-66-01.SDR SWAA2021050636370Slider · crackedLH HORIZONTAL STABILIZER FWD UPPER SLIDER IS CRACKED / R&R LH HORIZONTAL STABILIZER FWD UPPER SLIDER REF AMM 53-31-31.SDR SWAA2021050636371Slider · crackedRH HORIZONTAL STABILIZER FWD UPPER SLIDER IS CRACKED / R&R RH HORIZONTAL STABILIZER FWD UPPER SLIDER REF AMM 53-31-31.SDR SWAA2020011540474Sign · unsecureEMERGENCY EXIT SIGN FELL OFF ADJACENT TO LT SIDE OVERWING EMERGENCY EXIT DOOR. R&R SIGN ASSEMBLY PER MM.SDR SWAA2019112539131Bracket · looseLOOSE FLOOR DOOR MOUNTED EVACUATION SLIDE BRACKET R/H SIDE AT FORWARD GALLEY AREA. / SECURED BRACKET IAW AMM.SDR SWAA2019111338798Support · crackedAFT CARGO COMPARTMENT SUPPORT ZEE CRACKED AT BS. 727E, STR. 25R. / REPAIRED SUPPORT ZEE IAW SRM.SDR SWAA2019110638649Rib · crackedCRACK INSPAR RIB STA 129.50 AT 18 INCH FROM, FRONT SPAR LT HORIZONTAL STAB (1 EA). / REPAIRED INSPAR RIB IAW B737-700 SRM 55-10-09-2R-4 REPAIR 4.SDR SWAA2019111138759Splice Angle · corrodedEQUIPMENT ELECTRONIC COMPARTMENT SPLICE ANGLE CORRODED AT BS. 360+5, STR. 28L. / R&R SPLICE ANGLE IAW SRM AND DWG.SDR SWAA2019111138758Stringer Splice · corrodedEQUIPMENT ELECTRONIC COMPARTMENT STRINGER SPLICE CORRODED AT BS. 360+4, STR. 28L. / R&R STRINGER SPLICE IAW SRM AND DWG.SDR SWAA2022032360696Bracket · crackedCRACK BRACKET BS947.5 AT LEVEL STR26L AT AFT CARGO COMPARTMENT (1 EA) / REPLACED BRACKET AND FASTENERS LOC. BS 947.5 AT LEVEL STR26L AT AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 149A8103 REV ASDR SWAA2019110838712Cargo Track · crackedCRACK TRACK RBBL 13.84 BTW BS727E AND BS 747 AT AFT CARGO COMPARTMENT (2EA). / REPAIRED CARGO TRACK RBBL 13.84 BTW BS727E AND BS747 AT AFT CARGO COMPARTMENT IAW SRM B737-700 53-00-53-2R-3 REPAIR 3.SDR SWAA2019110138457Rib · crackedR/H HORIZONTAL STABILIZER INSPAR RIB CRACKED AT STAB. STA. 123.85, 36" FROM FRONT SPAR. / R&R INSPAR RIB IAW SRM.SDR SWAA2019110138407Intercostal · crackedAFT CARGO COMPARTMENT WEB-INTERCOSTAL CRACKED BETWEEN BS. 927 TO BS. 947.5, STR. 25R. / R&R WEB-INTERCOSTAL IAW DWG AND SRM.SDR SWAA2019110138406Beam · crackedR1 DOOR UPPER BEAM CRACKED CLOSE TO FIRST FASTENER HOLE ON INBOARD SIDE AT FORWARD GALLEY AREA. / R&R UPPER BEAM IAW DWG & SRM.SDR SWAA2019103138399Beam · crackedR1 DOOR THE LOWER BEAM CLOSE TO FIRST FASTENER HOLE ON INBOARD SIDE AT FORWARD GALLEY AREA CRACKED. / R&R LOWER BEAM IAW DWG & SRM.SDR SWAA2019103038375Rib · crackedL/H HORIZONTAL STABILIZER CRACKED INSPAR RIB STAB. STA. 123.85 36" FROM FRONT SPAR. / REPAIRED RIB IAW SRM.SDR SWAA2019103038374Rib · crackedL/H HORIZONTAL STABILIZER STRUCTURE INSPAR RIB CRACKED AT STAB. STA. 123.85, 19" FROM FRONT SPAR. / REPAIRED RIB IAW SRM.
Back to N914WN