N919FD
Service difficulty reports · 203
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N919FD' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N919FD' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 08FDEA03630Channel · corrodedLT FUSELAGE PANEL 197EL CENTER SUPPORT FRAME CHANNEL FACE HAS CORROSION. CORROSION FOUND EXCEEDED ALLOWABLE SRM LIMITS. CHANNEL REMOVED AND REPLACED IAW B757-200 SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03557Skin · dentedTWO DENTS FOUND ON FUSELAGE SKIN AT RT STA 395, WL208.10. REPAIR CARRIED OUT IAW FEDEX EA NR F-5330-111008. REPEAT INSPECTION REQUIRED WHEN AIRFRAME ACCUMULATES 37,500 FC AND THEREAFTER AT 12,000 FC INTERVAL. REPAIR IS CLASSIFIED AS MAJOR PER GMM 6-2-100 SDR 08FDEA03561Spar · corrodedLT AFT MAIN TANK BOOST PUMP HEAVY CORROSION ON SPAR. CORROSION REMOVED AND AREA TREATED IAW FEDEX EA NR F-5710-124306. REPAIR IS CLASSIFIED AS MAJOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03560Strap · corrodedAFT CARGO CORROSION ON SKIN STRAP AT BS 1400, RBL 20 BETWEEN S27R AND S28R. MINOR CORROSION ON STRAP REMOVED AND AREA TREATED IAW SRM 51-10-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100.SDR 08FDEA03559Floorbeam · corrodedMAIN CARGO FLOORBEAM HAS CORROSION AT BS 345, LBL 21 TO 34. MINOR CORROSION REMOVED, TREATED AND IS WITHIN ALLOWABLE DAMAGE LIMIT IAW SRM 53-00-51 REV. 93, FIG. 101. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03558Floorbeam · corrodedMAIN CARGO FLOORBEAM AT BS 377, LBL 22 HAS CORROSION. MINOR CORROSION ON FLOORBEAM REMOVED, TREATED, AND IS WITHIN ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-51 REV 93, FIG 101. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03508Sill · corrodedL1 DOOR SILL FACE HAS LIGHT CORROSION IN SEVERAL AREAS. MINOR CORROSION BLENDED OUT AND AREA TREATED, FOUND WITHIN ALLOWABLE LIMITS IAW SRM 53-00-01 REV 93, DETAIL II FIG 101. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03497Stringer · corrodedCORROSION ON STRINGER 6R AT BS 686 IN MAIN CABIN. CORROSION FOUND BEYOND SRM LIMITS. REPAIR CARRIED OUT IAW SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100.SDR 08FDEA03491Sill · corrodedR2 DOOR LOWER SILL HAS SEVERAL SPOTS OF SURFACE CORROSION. MINOR SURFACE CORROSION REMOVED IAW SRM 51-10-02 REV 93 AND FOUND WITHIN ALLOWABLE LIMITS. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03465Floorbeam · corrodedCABIN FLOORBEAM AT BS 350, LBL8, HAS CORROSION. MINOR SURFACE CORROSION BLENDED OUT AND SURFACE TREATED AND FOUND TO BE WITHIN ALLOWABLE LIMITS IAW B757-200, SRM 53-00-51 REV 93 DETAIL III, FIG 101. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03464Floorbeam · corrodedCORROSION ON CABIN FLOORBEAM AT BS 324, LBL 20. MINOR SURFACE CORROSION BLENDED OUT AND SURFACE TREATED, FOUND WITHIN ALLOWABLE LIMIT IAW B757-200 SRM 53-00-51 REV. 93 DETAIL III FIG 101. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03373Support · corrodedLT FUSELAGE BS 780-799, S-30 HAS CORROSION ON FWD SUPPORT FRAME AT SEVERAL PLACES. CORROSION FOUND EXCEEDED SRM LIMITS. REMOVED AND REPLACED SUPPORT FRAME IAW SRM 51-40-02 REV. 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03372Floor Support · corrodedMAIN CABIN RT FLOOR SUPPORT ANGLE FROM BS 630 TO BS 640, RBL 64 HAS CORROSION. CORROSION FOUND EXCEEDED SRM LIMITS. REMOVED AND REPLACED FLOOR SUPPORT ANGLE IAW B757-200 SRM 51-70-12 DETAIL VI. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03294Floorbeam · corrodedAT BS 1630, 63LBL, FLOOR SUPPORT ANGLE HAS CORROSION. CORROSION FOUND EXCEED SRM LIMITS. REPAIR CARRIED OUT IAW B757-200 SRM 51-70-12 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03226Skin · damagedLT LWR FUSELAGE FROM BS 1460 TO 1480 BETWEEN STR 27L AND 28L HAS EXISTING LIGHTNING STRIKE REPAIR. EXISTING REPAIR EVALUATED AS PER EO F-5100-7-5001 PT 1. FOUND ACCOMPLISHED IAW B757-200 REM 53-00-01 FIG 201, REPAIR 6 SECT 1, BASED ON EXTERNAL VISUAL EVALUSDR 08FDEA03225Skin · damagedLT LWR FUSELAGE FROM BS 1480 TO BS 1500, STR 27L AND 28L HAS EXISTING LIGHTNING STRIKE REPAIR. EXISTING REPAIR EVALUATED AS PER EO F-5100-7-5001 PT1 ATTACHMENT B, FOUND ACCOMPLISHED IAW B757-200 SRM 53-00-01 FIG 201 REPAIR 6 SECT 1, BASED ON EXTERNAL VISUAL ESDR 08FDEA03224Floorbeam · corrodedAT BS 650 RBL 8, CORROSION ON FLOOR SUPPORT BEAM. CORROSION FOUND EXCEEDED SRM LIMITS. STRINGER REMOVED AND REPLACED IAW B757-200 SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100.SDR 08FDEA03223Floorbeam · corrodedBS 1640 RBL 20 TO LBL 20 BULKHEAD FLOOR SUPPORT ANGLE HAS CORROSION. ANGLE ASSY AT BS 1640 BULKHEAD IS REPLACED UNDER EO F-2550-7-5001 PT 1: EQUIPMENT/FURNISHINGS, CARGO COMPARTMENT/LOADING SYSTEMS. REPLACE BS 1640 BULKHEAD, AFT CARGO COMPARTMENT SB 757-25SDR 08FDEA03222Skin · corrodedMINOR CORROSION FOUND ON WING LOWER INTERNAL SURFACE ACCESS 531AB WHILE CARRYING OUT TREATMENT. CORROSION REMOVED IAW SRM 57-20-01 REV 93 REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03221Frame · corrodedLOWER FUSELAGE LEFT MID SUPPORT FRAME FOR FAIRING 197LL HAS SURFACE CORROSION. REPAIR CARRIED OUT ON WING-TO-BODY FUSELAGE STRUCTURE LOWER CHORD IAW EA NR F-5320-124303. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100.SDR 08FDEA03205Fairing · crackedNR 1 PYLON STRUT AFT FAIRING LOWER PAN SKIN, AFT FOUND WITH A CRACK ABOUT 1/2 INCHES LONG. CRACKED SKIN REMOVED AND REPLACED IAW B757-200 SRM 54-50-70 REV 93 AND AMM 20-11-00 REV 2. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03204Fairing · crackedNR 2 PYLON STRUT AFT FAIRING LOWER PAN SKIN, AFT HAS ABOUT 1/3 INCH LONG CRACK NEAR PPSTA 276. CRACKED SKIN REMOVED AND REPLACED IAW B757-200 SSRM 54-50-70 REV 93 AND AMM 20-11-00 REV 2. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03203Floor Support · corrodedFLOOR SUPPORT AT BS 750 RBL 8 HAS CORROSION. CORROSION FOUND EXCEED SRM LIMITS. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-10-02 AND SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100.SDR 08FDEA03201Skin · damagedAT BS 860, STR 7L. DAMAGE REPAIR CARRIED OUT IAW SRM 53-00-01 REV 93, FIG 201, REPAIR 6, SECT I PARA 3. REPAIR IS CLASSIFIED AS MAJOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03200Skin · damagedLIGHTNING STRIKE AT BS 810, S7L. LIGHTNING STRIKE DAMAGE REPAIR CARRIED OUT IAW SRM 53-00-01 REV 93, FIG 201 REPAIR 6, SECT II PARA 3. REPAIR IS CLASSIFIED AS MAJOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03163Skin · corrodedSURGE TANK ACCESS PANEL CUTOUT 643BB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01, REV 93, REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03162Skin · corrodedFUEL ACCESS PANEL CUTOUT 543AB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93, REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03160Skin · corrodedFUEL ACCESS PANEL CUTOUT 543BB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV, 93 REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03159Skin · corrodedFUEL ACCESS PANEL CUTOUT 541EB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93 REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100.SDR 08FDEA03158Skin · corrodedFUEL ACCESS PANEL CUTOUT 541DB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93, REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03157Skin · corrodedFUEL ACCESS PANEL CUTOUT 541FB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93, REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03156Skin · corrodedFUEL ACCESS PANEL CUTOUT 541GB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93, REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03155Skin · corrodedFUEL ACCESS PANEL CUTOUT 541HB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93, REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100.SDR 08FDEA03154Skin · corrodedFUEL PANEL ACCESS CUTOUT 541JB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93, REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03153Skin · corrodedFUEL ACCESS PANEL CUTOUT 541KB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93, REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03152Skin · corrodedFUEL ACCESS PANEL CUTOUT 541LB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93 REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03151Skin · corrodedFUEL ACCESS PANEL CUTOUT 541MB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93 REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03150Skin · corrodedFUEL ACCESS PANEL CUTOUT 542AB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93 REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03149Skin · corrodedFUEL PANEL ACCESS CUTOUT 542CB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93 REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03148Skin · corrodedFUEL PANEL ACCESS CUTOUT 542DB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93. REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03122Floor Support · corrodedFLOOR SUPPORT FROM BS 653 TO BS 700, LBL 8, HAS CORROSION. CORROSION FOUND EXCEED SRM LIMITS. REMOVED AND REPLACED STRINGER IAW SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03121Floor Support · corrodedFLOOR SUPPORT FROM BS 653 TO BS 700, RBL 16, HAS CORROSION. CORROSION FOUND EXCEEDED SRM LIMITS. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03120Floor Support · corrodedFLOOR SUPPORT FROM BS 653 TO BS 700, RBL 10, FOUND WITH CORROSION. CORROSION FOUND EXCEED ALLOWABLE LIMITS IN SRM. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03105Panel · corrodedLEFT SIDE TRANSITION PANEL FROM BS 1200 TO BS 1310 HAS CORROSION. CORROSION FOUND OUTSIDE ALLOWABLE LIMITS IN SRM. PANEL REMOVED AND REPLACED IAW B757-200 SRM 51-10-02 AND SRM 51-40-02 REV 93. REPAIR IS CLASSIFED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03104Panel · corrodedRIGHT TRANSITION PANEL FROM BS 760 TO BS 845 HAS CORROSION. CORROSION FOUND OUTSIDE ALLOWABLE SRM LIMITS. PANEL REMOVED AND REPLACED IAW B757-200 SRM 51-10-02 AND SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03103Panel · corrodedRIGHT TRANSITION PANEL FROM BS 640 TO BS 765 HAS CORROSION. CORROSION FOUND OUTSIDE ALLOWABLE SRM LIMITS. PANEL REMOVED AND REPLACED IAW B757-200 51-10-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03102Panel · corrodedTRANSITION PANEL FROM BS 560 TO BS 645.75 HAS CORROSION. CORROSION FOUND BEYOND ALLOWABLE LIMITS IN B757-200 SRM 51-10-02. PANEL REPLACED IAW B757-200 51-10-02 AND 51-40-02. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03054Skin · corrodedFUEL TANK ACCESS CUTOUT 641EB HAS CORROSION. REPAIR CARRIED OUT IAW SRM 57-20-01 REV 93 REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03068Skin · corrodedFUEL ACCESS PANEL CUTOUT 541CB HAS CORROSION. REPAIR CARRIED OUT IAW B757-200 SRM 57-20-01 REV 93 REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03067Skin · corrodedFUEL ACCESS PANEL CUTOUT 541BB HAS CORROSION. REPAIR CARRIED OUT IAW B757-200 SRM 57-20-01 REV 93 REPAIR 5. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.
Back to N919FD