N934FD
Service difficulty reports · 539
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N934FD' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N934FD' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA200909283411Frame · corrodedAFT CARGO COMPARTMENT, FRAME AT STA 1620, RBL 9, AFT SIDE CORRODED. CORRODED FRAME AT STA 1620 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200909283410Intercostal · corrodedWEB AT STA 1620 - 1640, RBL 8 HAS (2) AREAS OF SURFACE CORROSION. CORRODED INTERCOSTAL WEB FROM STA 1620 TO STA 1640 REMOVED AND REPLACED IAW SRM 51-40-02, REV. 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283409Intercostal · crackedMAIN CABIN BS 480 TO 500, RBL 12 INTERCOSTAL CRACKED. CRACKED INTERCOSTAL WEB AT MAIN CABIN BS 480 TO 500 REMOVED AND REPLACED IAW SRM 51-40-02 REV. 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283408Cover · corrodedAFT CARGO BS 1640 TO 1660 LAV WASTE COVER CORRODED. CORRODED WATER SERVICE PANEL BETWEEN BS 1640 AND BS 1660 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283407Floor Panel · corrodedCABIN: STA 1705, LBL 51.0 INCHES, UPPER DECK PLATE HAS CORROSION. REPAIR CARRIED OUT IAW EA F-5320-133410. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283406Floor Panel · corrodedSTA 1715, RBL 36.5 INCHES, UPPER DECK PLATE CORROSION. REPAIR CARRIED OUT IAW EA F-5320-133410. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283405Floor Panel · corrodedBS 1715, RBL 10 INCHES UPPER DECK PLATE HAS CORROSION. REPAIR CARRIED OUT IAW EA F-5320-133410. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283404Support Angle · corrodedAFT CARGO BS 1200, ST 22L TO 26L SIDEWALL SUPPORT ANGLE CORRODED. CORRODED ANGLE AT BS 1200, STR 22L TO 26L REMOVED AND REPLACED IAW SRM 51-40-02, REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283403Floor Support · corrodedAFT CARGO BS 1200, STR 26L TO 26R BULKHEAD TO FLOOR SUPPORT ANGLE CORRODED. CORRODED ANGLE AT BS 1200 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283402Floorbeam · corrodedCABIN: STA 1680, RBL 52.5 INCHES, FLOORBEAM UPPER TEE HAS CORROSION AT BOTTOM SURFACE. REPAIR CARRIED OUT IAW EA NR F-5310-131056. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283401Support · corrodedAFT CARGO BS 1200, STR 22R TO 26R SIDEWALL SUPPORT CORRODED. CORRODED SIDEWALL SUPPORT AT BS 1200 REMOVED AND REPLACED IAW SRM 51-40-02. REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909243379Plate · corrodedSTA 1687, RBL 13.0 INCHES, UPPER DECK PLATE HAS CORROSION. CORROSION ON DECK PLATE FOUND OUT OF SRM LIMITS. CARRIED OUT DOUBLER REPAIR IAW SRM 51-40-02 REV. 98. REPAIR IS CLASSIFIED AS MAJOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909243377Bracket · corrodedRT FWD WING-TO-BODY FAIRING, LT PACK RAM AIR INLET SCOOP HAS A BRACKET CORRODED AT TOP OF SCOOP. RT FWD WING TO BODY FAIRING, RAM AIR INLET SCOOP CORRODED BRACKETS (CHANNELS) REMOVED AND REPLACED IAW SRM 51-40-02 REV. 97 QTY 2 CHANNEL FABRICATED IAW DWG 149SDR FDEA200909233375Support Bracket · corrodedAFT CARGO COMPARTMENT SUPPORT BRACKET BETWEEN FLOOR SUPPORT BEAM CORRODED ON LOWER SURFACE AT STA 1661-1681.9. REMOVED AND REPLACED IAW SRM 51-40-02 REV. 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909233374Intercostal · corrodedAFT CARGO COMPARTMENT INTERCOSTAL CORRODED AT STA 1602-1607, RBL 2.5 AND AT STA 1615-1620, RBL 2.5. CORRODED INTERCOSTAL WEB FROM STA 1600 TO STA 1620 REMOVED AND REPLACED IAW SRM 51-40-02 REV.98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909233373Intercostal · corrodedWEB AT STA 1620, LBL 7 CORRODED. CORRODED INTERCOSTAL WEB FROM STA 1620 TO STA 1640 REMOVED AND REPLACED IAW SRM 51-40-02, REV.98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909223366Skin · corrodedINSIDE NR 1 PYLON HAS EXFOLIATED SKIN, LBL 9.5 INCHES BETWEEN PP STA 125 AND PP STA 144, APPROX PP WL 137. REMOVED AND REPLACED IAW SRM 51-40-02, REV 98. REPAIR IS CLASSIFIED AS MAJOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909223361Angle · corrodedAFT CARGO COMPARTMENT ANGLE CORRODED AT STA 1640 BETWEEN S-26L AND S-27L. CORRODED ANGLE REMOVED AND REPLACED IAW SRM 51-40-02, REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909223360Frame · corrodedAFT CARGO COMPARTMENT FRAME AT STA 1660 CORRODED FROM LBL 18 TO RBL 15. CORRODED FRAME AT STA 1660 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98 REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909223359Bracket · crackedAFT CARGO COMPARTMENT BRACKET CRACKED AT STA 1380, STR 26L, LBL 29. CRACKED BRACKET REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909223358Frame · corrodedAFT CARGO BS 1640 STR 26L TO 26R FRAME CORRODED. CORRODED FRAME AT BS 1640 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MAJOR IAW GMM 6-2-100.SDR FDEA200909223357Stringer · corrodedAFT CARGO BS 1640, STR 26L CORRODED. CORRODED STR 26L REPAIRED IAW EA F-5310-131055. REPAIR IS CLASSIFIED AS MAJOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909183324Frame · damagedMAIN CABIN BS 1100 STR 6L FRAME HAS DOUBLE HOLE. DAMAGE REPAIRED IAW EA NR F-5310-133412 : INSTALLATION OF PLUG IN AN EXISTING ELONGATE HOLE AT BS 1100 S-6L. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909173313Angle · crackedAFT CARGO COMPARTMENT INTERCOSTAL LWR ANGLE CRACKED AT STA 1437, RBL 13.5. CRACKED ANGLE AT STA 1437, RBL 13.5 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909143295Angle · crackedMAIN CABIN BS 1660 TO 1680 RBL 10 INTERCOSTAL CRACKED. CRACKED INTERCOSTAL ANGLE REMOVED AND REPLACED IAW SRM 51-40-02 REV.98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909133294Intercostal · corrodedWING-TO-BODY FAIRING FRAME SPLICE BETWEEN BS 780 AND BS 800, BL 0 HAS EXFOLIATION CORROSION WITH SIXTEEN CORRODED NUTPLATES. EVALUATE AND RECTIFY. WING-TO-BODY FAIRING FRAME SPLICE AT BS 780 TO BS 800 REMOVED AND REPLACED IAW SRM 51-40-02 REV. 97. INTERCOSTSDR FDEA200909103284Floorbeam · crackedMAIN DECK BS 1014, LBL 24 TO LBL 45 FLOOR SUPPORT SHIM CRACKED. CRACKED COVER PLATE AT BS 1014 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR GMM 6-2-100 CRITERIA.SDR FDEA200909103283Floorbeam · crackedMAIN DECK BS 900, RBL 24 TO RBL 45 FLOOR SUPPORT SHIM CRACKED. CRACKED COVER PLATE AT BS 900 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909103282Floorbeam · crackedMAIN DECK BS 1060, LBL 24 TO LBL 45 FLOOR SUPPORT SHIM CRACKED. CRACKED COVER PLATE AT BS 1060 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909103281Floorbeam · crackedMAIN DECK BS 1014, RBL 24 TO RBL 45 FLOOR SUPPORT SHIM CRACKED. CRACKED SHIM PLATE AT BS 1014 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909103280Shim · crackedMAIN DECK BS 1054 RBL 24 TO RBL 45 FLOORBEAM SHIM CRACKED. REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909093276Floorbeam · corrodedMAIN CABIN BS 334 LBL 20 FLOORBEAM CORRODED. CABIN BS 334, LBL 20 FLOOR MOUNT FITTING REMOVED AND REPLACED IAW SRM 51-40-02 REV. 97. THIS REPAIR IS CLASSIFIED AS MINOR GMM 6-2-100 CRITERIA.SDR FDEA200909093275Floor Support · corrodedMAIN CABIN BS 353 TO BS 365, LBL 60 FLOOR SUPPORT "U" CHANNEL CORRODED. MAIN CABIN BS 353 TO BS 365, LBL 60 FLOOR SUPPORT "U" CHANNEL REMOVED AND REPLACED IAW SRM 51-40-02. THIS REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909093274Floor Support · corrodedMAIN CABIN BS 342 TO BS 365, RBL 60 FLOOR SUPPORT "U" CHANNEL CORRODED. MAIN CABIN BS 342 TO BS 365, RBL 60 FLOOR SUPPORT "U" CHANNEL REMOVED AND REPLACED IAW SRM 51-40-02 REV. 98. THIS REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909093273Frame · gougedMAIN CABIN BS 1280 STR 10R FRAME DOUBLER GOUGED. REPAIR DOUBLERS FABRICATED IAW SRM 53-00-07 REPAIR 1 REV 98. REPAIR DOBLER REMOVED AND REPLACED AS PER SRM 53-00-07, REPAIR 1 REV 98. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909093272Frame · gougedMAIN CABIN BS 1280, STR 11L TO 12L FRAME DOUBLER GOUGED. REPAIR DOUBLERS FABRICATED IAW SRM 53-00-07 REPAIR 1 REV. 98. REPAIR DOUBLERS REMOVED AND REPLACED IAW SRM 53-00-07 REPAIR 1 REV. 98. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909093271Tee Fitting · crackedRH WTB UNDERWING FAIRING SUPPORT STRUCTURE CHANNEL FITTING IS CRACKED AT BS 1070, RBL 67", BELOW ELECTRIC MOTOR PUMP RIGHT SYSTEMS. RT WING-TO-BODY UNDERWING FAIRING SUPPORT STRUCTURE CHANNEL, REMOVED AND REPLACED PER SRM 51-40-02 REV. 97. REPAIR IS CLSDR FDEA200908313196Frame · corrodedLT FWD WING-TO-BODY FAIRING SPLICE FRAME BETWEEN BS 800 TO BS 820, BL 0 HAS EXFOLIATION CORROSION. EVALUATE AND RECTIFY. LT FWD WING TO BODY FAIRING SPLICE FRAME AT BS 800 TO BS 820, BL 0, UPPER INTERCOSTAL FRAME REMOVED AND REPLACED IAW SRM 51-40-02 REV 9SDR FDEA200908313195Intercostal · corrodedWING-TO-BODY FAIRING LWR INTERCOSTAL TEE FRAME SPLICE BETWEEN BS 800 TO BS 820, BL 0, HAS INTERGRANULAR CORROSION. EVALUATE AND RECTIFY. WING-TO-BODY FAIRING, FRAME SPLICE LR INTERCOSTAL TEE REMOVED AND REPLACED IAW SRM 51-40-02 REV. 97. INTERCOSTAL TEE FABR
Back to N934FD