FAA incident reports · 6
FAA accident and incident reports matched to this aircraft by N306WA and the event date: up to this one’s cancellation.
Incident 20001116039439IFinal Approach · Colorado Spring, CO(-23) INM0300102-emergency declared during landing at cos. Both generators failed. Unable to reset. A/c landed on battery power. APU start not attempted. After landing fire marshalls conducted exterior check at request of cpt. Nothing found. After landing and…Incident 19980915033689INormal Cruise · Salt Lake City, UT-23 After reviewing the capt statement and confirming his description of t he incident with ATC and fss in cdc, it is concluded this incident occurred while the aircraft, a B-737, was being vectored to final at approximately 8000 MSL. The aircraft encountered…Incident 19890727047939IRoll-Out (Fixed Wing) · Jackson, WYAircraft ran off end of runway during landing. Rubber build up on last part of runway.Incident 19890606040909IForced/Precautionary Landing · Buffalo, NYAirframe vibrations on takeoff. Returned. Found problem with pressurization system. Replaced flow control valve.Incident 19870813056479IDescent · Milford, UTThe aircraft encountered clear air turbulence during descent. One passenger injured.Incident 19860201004089IStarting Engines · Omaha, NEDuring start attempt after pushback engine backfired and would not start. Engine to be changed.
Service difficulty reports · 23
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR DL733060250Stiffener · crackedDURING ACCOMPLISHMENT OF 05-086589-12AD, THE WING CENTER SECTION REAR SPAR STIFFENER AT LBL 6.15 WAS FOUND CRACKED. REPLACED REAR SPAR STIFFENER.SDR DL733050148Skin · crackedTHE FUSELAGE SKIN WAS FOUND WITH A 4 INCH CRACK AT FS 870 JUST ABOVE THE BONDED DOUBLER MILL LINE AT STRINGER 23R. THE CRACK IS TYPICAL OF AD 2004-18-06. THE CRACK WAS REMOVED WITH A CUTOUT AND REPAIRED WITH AN EXTERNAL ALUMINUM REPAIR DOUBLER PER B737-300 SSDR DL733030081Coffeemaker · odorFLT ATTENDANT VERBAL REPORT, LT AFT GALLEY COFFEEMAKER HAS ELECTRIC ODOR. REPLACED COFFEEMAKER, OPS CHECK NORMAL. NO ODOR.
See all 23 reports