Service difficulty reports · 37
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR YENA201909270552Crossbeam · corrodedDURING HEAVY MAINTENANCE, AEROMAN REPORTED CORROSION DAMAGE FOUND ON THE UPPER FLANGE ON THE FR16 LH CROSS BEAM AT THE FWD FUSELAGE. SEE REF /1/ EA FOR MORE DETAILS. THE DAMAGE WAS REMOVED BY BLEND OUT PER E190 SRM 51-10-03 AND REMAINING THICKNESSES WERE MEASUSDR YENA201909270551Floorbeam · corrodedDURING HEAVY MAINTENANCE, REF AEROMAN NR 2019-258707. CORROSION FLOOR BEAM FR16 LH SIDE FWD GALLEY AREA; REF NR FOR ALL WORK ACCOMPLISHED. REPLACED FLOOR BEAM FR12-FR20 LH FWD GALLEY AREA IAW SRM 51-40-08 & DWG 170-00822-505-001. CLASSIFIED AS MAJOR REPAIR.SDR YENA201909270550Skin Panel · crackedDURING HEAVY MAINTENANCE, CRACK LOWER SURFACE REAR SPAR AT RIB 4 ON RH WING; AEROMAN WO# 2019-193/1 WCC# 2019-258713 REPAIRED LOWER SKIN PANEL AT REAR SPAR COMMON TO THE RIB 4 ON RH WING IAW EC E190-682-01 AND EA 57-5003-19 REV O (COVER AND PARTS 1-4) THIS REP