Service difficulty reports · 2
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR 2009F00065Reservoir · failedAPPROX 5 MINUTES INTO DEPARTURE, DURING CLIMBOUT, CREW WAS ALERTED BY AN EICAS MESSAGE "HYD SYS NR 2 OVER TEMP". DECISION WAS MADE TO RETURN TO DEPARTURE. AS THE ACFT DESCENDED, CREW NOTED THE MESSAGE EXTINGUISHED AND THE TEMPS STARTED TO COOL OFF. ACFT MADSDR Q7F2009F00000Actuator · failedAPPROX 6 HRS INTO FLIGHT, CREW REPORTED "HYD 1 LO QTY" MESSAGE POSTED TO EICAS. DECISION WAS ADE TO DIVERT TO PREVENT FURTHER DAMAGE DUE TO PUMP CAVITATIONS SHULD QTY GO TO ZERO. UPON INSP THE RT OTBD MULTI FUNCTIONAL SPOILER ACTUATOR WAS FOUND TO HAVE FAILE