N516MC, cancelled Jun 6, 2011
Service difficulty reports · 104
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N516MC' AND deregistration_id = 'N516MC-2011-06-06' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N516MC' AND deregistration_id = 'N516MC-2011-06-06' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA200700182Fitting · crackedM/D RT BS 840 FRAME TO TENSION TIE CONNECTION FOUND NR 8 HOLE CRACK AT TENSION TIE AFT CHANNEL. CRACKED AFT CHANNEL REPAIRED AS PER BOEING MSG 1-303978264-2.SDR UIEA200700185Attach Fitting · crackedM/D RT BS 880 FRAME TO TENSION TIE CONNECTION FOUND NR 6 HOLE CRACK AT TENSION TIE FWD CHANNEL. CRACKED AFT CHANNEL REPAIRED AS PER BOEING MSG 1-303986330-2.SDR UIEA200700184Attach Fitting · crackedM/D LT BS 840 FRAME TO TENSION TIE CONNECTION FOUND NR 5 HOLE CRACK AT TENSION TIE AFT CHANNEL. M/D LT BS 840 FRAME TO TENSION TIE CONNECTION TENSION TIE AFT CRACKED CHANNEL REPAIRED AS PER BOEING MSG 1-303978264-2.SDR UIEA200700183Attach Fitting · crackedM/D LT BS 840 FRAME TO TENSION TIE CONNECTION FOUND NR 4 HOLE CRACK AT TENSION TIE FWD CHANNEL. CRACK FWD CHANNEL REPAIRED AS PER BOEING MSG 1-303978264-2.SDR UIEA20070039Duct · crackedNR 3 PYLON AIR VALVE INDICATES 10-PSI IN CRUISE WITH 95 PERCENT N1 SET IS NOT REGULATING CORRECTLY WITH ISOLATION VALVE OPEN. THE LEFT AND RIGHT MANIFOLD PRESSURE ONLY INDICATE 26-PSI. LEAK CHECK FOUND NO FAULT ON ENGINE AREA. SUSPECT CRACKED DUCT ON THE WISDR UIEA200600302Connector · dirtyON DESCENT, NR 2 ENGINE EGT WENT TO ZERO WITH A VISIBLE BARBER POLE. CLEANED CONNECTOR ON FORWARD LEAD GROUND, OPS CHECKED PER 77-21-00, CHECKED OKAY.SDR UIEA200600299Gcu · failedAIRCRAFT DIVERTED TO JFK DUE TO NR 3 ENGINE GEN BUS TIE OPEN, FIELD OFF LIGHT ON. ZERO VOLTAGE ZERO FREQS. THEN NR 4 BUS TIE GEN OPEN FIELD OFF LIGHT ON, VOLTS AND FREQS NORMAL. REPLACED NR 3 GCU AND REPLACED THE RT BPCU BOTH ENGINES, OPS CHECKED OKAY AND ASDR UIEA200600296Sensor · unserviceableUNABLE TO MAKE COMPUTED T/O N1 FOR NR 2 ENGINE. REMOVED AND REPLACED NR 2 ENGINE CIT SENSOR IAW MM 73-21-02. CHECKED CDP LINE FOR BLOCKAGE. ACCOMPLISHED VSV/VBV RIG CHECK IAW MM 75-30-00. LEAK CHECK GOOD.SDR UIEA200600295Skin · corrodedCORROSION FOUND BETWEEN UPPER WING SKIN REAR SPAR AREA AND FLYING PANEL AT STATION 406. REPAIR CARRIED OUT IAW XEO 57-112106 AND SRM 57-30-01 FIG 1.SDR UIEA200600294Skin · corrodedCORROSION FOUND ON RT WING REAR EDGE BETWEEN REAR SPAR UPPER SKIN AND FWD EDGE OF FLYING PANEL. PANELS AT STA 456 AND 586. LEVEL 1 CORROSION. REPAIR CARRIED OUT PER XEO 57-112206 AND SRM 57-30-01 FIG 1.SDR UIEA200600253Control Valve · failedBLOCK TURN BACK, DUE TO SMOKE IN COCKPIT APPEARS TO BE BLEED AIR SMOKE. NR 3 PACK VALVE CLOSED ACM OUTLET TEMP 85 DEGREES C, NO TRIP. SUSPECT SMOKE CAME FROM CONTAMINATED AIR DUCT AND DUE TO ACM NR 3 ABOVE 85 DEGREES C. PERFORMED OPS TEST, AIR CONDITIONING SDR UIEA200600178Tire · separatedAIR TURN BACK DUE TO TIRE SEPARATION AFTER TO. UPON ARRIVAL MAINTENANCE FOUND ALL 4EA WHEELS ON LT BODY GEAR SEPARATED. ADDITIONAL DAMAGE FOUND TO LT BODY GEAR TRUCK ASSY, FLAP DRIVE TUBES, LOWER FUSELAGE, NR 2 VHF ANTENNA, HYDRAULIC LINES WHEEL WELL AND BODY SDR UIEA200600174Valve · damagedABORTED TAKEOFF, POOR ACCELERATION. A/C PULLING LEFT AFTER A/C STOPPED ON RUNWAY, ALL BRAKES LOCKED UP AND WOULD NOT RELEASE FOR APPROX 20 SECONDS. LEFT WING AND BODY,LEFT FRONT AND LEFT REAR IN RED SCALE 8+, PULLED VOICE RECORDER C/B. REMOVED AND REPLACED SDR UIEA200600120Pdu · failedAIR TURNBACK, NR 3 LEADING EDGE FLAP LEFT WING WOULDN'T RETRACT ELECTRICALLY. PNEUMATICS WAS DISCONNECTED FOR PREVIOUS WRITE UP PAGE 597439. DUMPED 26.5 KILO OF FUEL. REMOVED AND REPLACED THE LEFT HAND NR 3 L/E PDU IAW MM 27-81-03.SDR UIEA200600019Seat Track · brokenMAIN DECK CARGO COMPT, SEAT TRACK IS MISSING TWO TABS BY THE MAIN CARGO DOOR BS 1800. REPLACED SEAT TRACK PER SRM 53-10-05 AND EO4753A686.SDR UIEA200600016Panel · crackedNR 6 SPOILER HAS A SMALL CRACK AT OUTBOARD SIDE OF ACTUATOR HINGE FITTING ,1ST ROW, FWD HI-LOK, FROM DOUBLER EDGE TO HI-LOK. REMOVED AND REPLACED NR 6 SPOILER PANEL ASSY AS PER 747 MM 27-62-01.SDR UIEA200600005Controller · malfunctionedNR 3 PACK CONTROL CIRCUIT BREAKER ON P6 PANEL TRIPPED AFTER TAKEOF. STRONG ELECTRICAL ODOR DETECTED NEAR POSITION E-L. SMELL DISIPATED AFTER 3 HOURS. CIRCUIT BREAKER NOT RESETSDR UIEA200400202Shutoff Valve · leakingDURING CRUISE, LOSS OF FLUID NR 4 HYD SYSTEM. SYSTEM DEPRESSURIZED AT 2.0 GALS QUALITY. EDP TO SUPPLY OFF. FOUND NR 4 RUDDER CONTROL SHUTOFF VALVE FAILED. (LEAKED) REMOVED AND REPLACED NR 4 RUDDER SHUTOFF VALVE. OPS AND LEAD CHECK GOOD IAW MM. (K)SDR UIEA200400174Connector · inoperativeAIRCRAFT EMERGENCY LIGHT FLICKER MOST OF THE FLIGHT. FOUND SEVERAL PUSHED BACK PINS AT CONNECTOR EMERGENCY LIGHT PANEL. ACCOMPLISHED GROUND CHECK OK PER MM 33-51-10. (M)SDR UIEA200400175Relay · inoperativeEMERGENCY LIGHT FLICKER DURING FLIGHT. FOUND RELAYS ON EMERGENCY LIGHTS UNSECURED, RESECURED RELAYS OPS CHECK OK IAW MM 33-51-07. REMOVED AND REPLACED BOTH RELAYS ON EMERGENCY LIGHT CNTL PANEL LIGHTS OPS OK PER MM 33-51-07. (M)SDR UIEA200400145Skin · scratchedDURING SCHEDULE MAINTENANCE, FUSELAGE SKIN DAMAGE WAS FOUND ADJACENT TO THE CARGO DOOR. THE SKIN DAMAGE WAS REMOVED BY BLENDING OUT THE DAMGAE. NO FASTENERS WRE AFFECTED BY THE BLEND OPERATION. HFEC SURFACE INSPECTED TO ENSURE NO DEFECTS EXIST. BOEING ADVISDR UIEA200400144Floorbeam · crackedDURING INCORPORATION OF SB 747-53A2459, FOUND CRACK AND OR ELONGATED FASTENER HOLES COMMON TO FRAMES AND UPPER DECK FLOORBEAM UPPER CHORDS AT BS 340/360. FLOORBEAM UPPER CHORDS AND WEBS REPAIRED PER SRM. AT BS 340, STOP DRILLED AND REPAIRED FRAME WEB. OPEN SDR P5CA0401085Accumulator · leakingAFTER ENG START, NR 1 AND 4 LOST HYD SYSTEM QTY. REPLACED BRAKE ACCUMULATOR AS PER MM 32-41-23. OPS AND LEAK CK NORMAL. RESTARTED NR 1 AND 4, HYD SYSTEM TO PROPER LEVEL.SDR UIEA200400040Fan · inoperativeDURING TAXI IN, SMELL OF SMOKE FROM THE AIR CONDITIONING SYSTEM. FLIGHT DECK FAN SWITCHED OFF WITH NO FURTHER SMELL. AFTER SHUTDOWN, UNABLE TO SWITCH FAN BACK ON. CIRCUIT BREAKER PULLED AND ITEM TRANSFERRED DMI M04-064. REMOVED AND REPLACED FLIGHT COMPARTMSDR UIEA200300069Fire Loop · shortedNR 2 ENGINE INDICATED FIRE ON APPROACH, SHOT BOTH BOTTLES, INDICATIONS CONTINUED. FOLLOWED FHB PROCEDURES FOR ENGINE FIRE CHECKLISTS. DISCHARGED FIRST BOTTLE, TIMED 30 SECOND LIGHT REMAINED ON. DISCHARGED SECOND BOTTLE, LIGHT REMAINED ON. B-LOOP REMAINED OSDR UIEA200300018Warning Light · false indicationINFLIGHT ENGINE SHUTDOWN, NR 2 ENGINE WAS SHUTDOWN DUE TO FIRE DETECTION LIGHT AND FAULT LIGHT. NR 2 FIRE DETECTION 'A' LOOP WOULD NOT TEST. COMPLETED ENGINE SHUTDOWN CHECKLIST. HYDRAULIC SYSTEM SHUTDOWN FOR 20 MINUTES. INCIDENT TIME FRAME, AIRCRAFT DEPARTSDR UIEA200300002Beam · crackedDURING CURRENT C-CHECK AT SIA, FOUND RT WING LE BEAM WEB CRACKED AT OLES 1200. CRACK REMOVED BY CUTTING THE WEB AT OLES 1190 AND DISCARDING THE INBOARD SECTION FROM OLES 1190 TO 1200. PERFORMED HFEC INSPECTION OF CUT EDGE TO ENSURE CRACK FREE CONDITION. NO SDR UIEA200300005Skin · crackedDURING CURRENT C-CHECK AT SIA, FOUND BS 1241 L/S KICK FITTING AT BOLT HOLE NR 11 CRACKED IN WING SKIN ONLY. REAMED HOLE TO 1.169 INCH. NO CRACK INDICATION. FINAL REAMED HOLE TO 1.284 INCH IN WING SKIN AND CHORD. REAMED STRINGER SPLICE FITTING TO 1.126 INCHSDR UIEA200300003Skin · wrinkledDURING CURRENT C-CHECK AT SIA, FOUND NR 2 PYLON R/S SKIN WRINKLED TWO PLACES FROM 1) NAC 286 TO 300 AT STR 5, 2) NAC 300 TO 316 AT STRINGER6. REPAIR AREA (1) CUTOUT EXISTING DAMAGE IN FLAT BAY AREAS ONLY. HFEC INSPECTED ALL OPEN HOLES, CUT EDGES AND ADJACENTSDR UIEA200300001Spar · corrodedDURING CURRENT C CHECK, FOUND LT STABILIZER REAR SPAR CORRODED AT STABILIZER B/L 372, STA 550. NO ESTABILISHED LEVEL OF CORROSION DECLARED SINCE ITEM DISCOVERED DURING ROUTINE INSPECTION. REMOVED EXISTING SPAR SPLICES LOCATED AT STAB STA. 525 AND 570. REMOVSDR UIEA01071Intercostal · crackedDURING INSPECTION, FOUND MAIN DECK FLOOR LINE INTERCOSTALS FROM STATION 340-380 LEFT CRACKED AT NUMEROUS FASTENER HOLES. TRIMMED OFF SHEAR TIES CONTAINING CRACKED FASTENER HOLES. PERFORMED HFEC INSPECTION AT CUT LINE TO ENSURE NO CRACKS. NO CRACKS FOUND. FSDR UIEA01070Frame · crackedDURING INSPECTION, FOUND FRAME WEB AND DOUBLER STATION 440 CRACKED AT STRINGER 13R, CRACK ENDS IN EXISTING FASTENER LOCATION. PERFORMED OPEN HOLE HFEC INSPECTION TO ENSURE CRACK CONTAINMENT. FABRICATED DOUBLERS AND FILLERS. INSTALLED PER STANDARD PRACTICES SDR UIEA01069Frame · crackedDURING INSPECTION, FOUND FRAME WEB STATION 220 CRACKED AT STRINGER 14R, 1.2 INCH COMMON TO THE TRIANGULAR CUTOUT. STOP DRILLED CRACK. PERFORMED OPEN HOLE HFEC INSPECTION TO ENSURE CRACK CONTAINMENT IN STOP HOLE. FABRICATED DOUBLER AND INSTALLED PER STANDARDSDR UIEA01068Frame · crackedDURING INSPECTION, FOUND FRAME AND DOUBLER STATION 520 CRACKED AT STRINGER 10A (L) AND 11L COMMON TO THE STRINGER CUT-OUT AT 10A(L) AND 11L. FABRICATED DOUBLERS AND INSTALLED PER STANDARD PRACTICES IAW SRM 53-10-04. CLIP REPLACED. REINSPECT AREA PER SB 747-SDR UIEA01067Frame · crackedDURING INSPECTION, FOUND FRAME DOUBLER AND CLIP COMMON TO STATION 500 CRACKED AT STRINGER 10A (L) AND 11L. FABRICATED DOUBLERS AND INSTALLED PER STANDARD PRACTICES IAW SRM 53-10-04. CLIP REPLACED. REINSPECT AREA PER SB 747-53A2265 AT 3000 CYCLE INTERVALS. SDR UIEA01066Frame · crackedDURING INSPECTION, FOUND FRAME WEB DOUBLER STATION 420 CRACKED AT STRINGER 16L COMMON TO THE STRINGER CUT-OUT. CRACK NOT STOP DRILLED DUE TO CRACK PROXIMITY TO EDGE OF THE PART. FABRICATED DOUBLER AND INSTALLED PER STANDARD PRACTICES IAW SRM 53-10-04. REINSSDR UIEA01065Doubler · crackedDURING INSPECTION, FOUND FRAME STATION 420 CRACKED AT STRINGER 14 (E)L AND STRINGER 15L AT THE SHEAR DOUBLER COMMON TO THE STRINGER CUTOUT. TRIMMED AWAY TWO FASTENER ROWS OF THE OUTBOARD REINFORCING ANGLE. STOP DRILLED CRACKS. FABRICATED FILLER, DOUBLERS ANSDR UIEA01064Frame · crackedDURING HFEC INSPECTION, FOUND FRAME STATION 800 CRACKED AT STRINGER 17R COMMON TO THE AFT INNER CHORD AT A FASTENER HOLE. TRIMMED OUT CRACK. FABRICATED FILLER AND REPAIR STRAPS AND INSTALLED PER STANDARD PRACTICES IAW SRM 53-10-04 FIG 114. HFEC (FLAT SURFACSDR UIEA01063Frame · crackedDURING INSPECTION FOUND FRAME STATION 480 CRACKED AT STRINGER 14R COMMON TO THE CUTOUT. STOP DRILLED CRACK. FABRICATED REPAIR DOUBLER AND INSTALLED PER STANDARD PRACTICES IAW SRM 53-10-04. REINSPECTION TO BE ACCOMPLISHED AT 3000 CYCLES AND REPETITIVE AT 300SDR UIEA01062Skin · crackedDURING HFEC INSPECTION, FOUND THE LOWER AFT CARGO COMPARTMENT DOOR CUT-OUT, UPPER FORWARD CORNER SKIN CRACKED. CRACK TRIMMED AWAY. FILLER AND REPAIR DOUBLERS FABRICATED AND INSTALLED PER STANDARD PRACTICES IAW SRM 53-30-03 FIG 60, TYPE II. REINSPECTION IS RSDR UIEA00053Turbine · failedATB - FLT 3120 - CREW HEARD A LOUD BANG FROM RIGHT SIDE OF AIRCRAFT, THEN NR 4 ENGINE SHUTOFF. UPON RETURN TO LAX, IT WAS DISCOVERED THAT NR 4 ENGINE TURBINE SECTION HAS FAILED AND THE ENGINE HAS INTERNAL DAMAGE. SEVERAL BLADES FOUND DAMAGED DURING BORESCOPESDR UIEA00049Engine · flamed outFLT 9027 - BOM-MAA - NR 2 ENGINE FLAME OUT AT FL370. ALL ENGINE INDICATIONS WERE NORMAL AND ENGINE WAS RUNNING FINE. ACCOMPLISHED IN FLIGHT RESTART AT FL290. MAINTENANCE CHECKED ENGINE INLET AND EXHAUST AREA AND NO DEFECTS WERE FOUND. INSPECTED ENGINE TUBISDR UIEA0017Skin · damagedDURING INTERNAL INSPECTION OF PYLON NR 1, NR 2, NR 3 STRUCTURE SURROUNDING THE PRECOOLER EXHAUST EXIT AREA FOUND METAL DISCOLORED AND EXTERNAL SKIN CREASED. OVER TEMPERATURE ANALYSIS INDICATED TEMPER LOSS AND HEAT RELATED DAMAGE. AFFECTED STRUCTURE AND SKIN SDR UIEA0011Intercostal · crackedFOUND NR 3 LEFT/RIGHT MAIN ENTRY DOOR FRAME CRACKED AT BS 1265. LEFT CRACKED 1.6875 INCH ON EACH SIDE OF RIVET. PER BOEING SB 747-53A2416 TRIMMED OUT CRACKED AREA AND FILLER REPAIRED FRAME. REFERENCE KLM DRAWING KLM-AMS-99-0913RE FOR REPAIRS UP TO 3 INCHES.SDR UIEA0012Fitting · corrodedRIGHT STATION 1480 BULKHEAD CORROSION REPAIR COMMON TO STRINGER 38R. FOUND HOLES NR 2, 3, 5, 7, AND NR 10 CRACKED. REAMED HOLES OVERSIZE, ALL WITHIN LIMITS PER SB 747-53A2390. OVERSIZED FASTENERS INSTALLED. (M)SDR UIEA0013Fitting · crackedLEFT STATION 1480 BULKHEAD CORROSION REPAIR COMMON TO STRINGER 38L. FOUND HOLES NR 3, 4, 7, 8, 9, 10 AND NR 11 CRACKED. REAMED HOLES OVERSIZE, AND INSTALLED BUSHING REPAIRS AT LOCATION NR 3, 7, 8, 9, 11. OVERSIZED FASTENERS INSTALLED PER SB 747-53A2390. (MSDR UIEA0014Splice · damagedLEFT STATION BULKHEAD CHORD SPLICE FITTING 65B14682-3 FOUND TOOLING MARKS DURING DISASSEMBLY. PER BOEING TELEX TLS-TPE-00-00047F, BLEND ALL TOOLING MARKS. ALL TOOL MARKS BLENDED. (M)SDR UIEA0015Spar · corrodedSURFACE CORROSION DETECTED CENTER SECTION REAR SPAR LEFT/RIGHT. CORROSION MAPPED, MEASURED, CLEANED AND TREATED BY BOEING FIELD TEAM. ALL WITHIN LIMITS. AREAS OF REWORK ARE; LEFT FASTENERS NR 7, 8, 9, RIGHT FASTERNERS NR 2, 3, 4, 5, 6, 7, 8, 9, 13, 14, 23 ASDR 20000505AP036Spar · corrodedFOUND CORROSION ON WING CTR SECTION REAR SPAR RBL 99, COMMON TO REAR BULKHEAD FITTING AND INBOARD WEB OF LEG TO TWO BOLT HOLES WHILE PERFORMING SB 747-57-2263. CLEANED, TREATED, MEASURED CORROSION. APPLIED FINISH. ALL WITHIN ACCEPTABLE LIMITS. (M)SDR UIEA9947Manifold · crackedORD/MXP - FLT AZ9163/02 - DURING CLIMB-OUT AT 4,000 FEET, NR 4 ENGINE NACELLE TEMPERATURES INDICATED 7.6 DEGREES ON BOTH 'A' AND 'B' LOOPS. TEMPERATURE DECREASED WHEN THROTTLE WAS RETARDED. CLOSED BLEED VALVE ACCORDING TO FHB PROCEDURE. AS NR 4 THROTTLE WAS