N8084U, cancelled May 17, 2006
Service difficulty reports · 168
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8084U' AND deregistration_id = 'N8084U-2006-05-17' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8084U' AND deregistration_id = 'N8084U-2006-05-17' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA010064Indicator · failedNR 1 EGT REACHED 907 DEGREES C FOR APPROX 8 SEC ON MAX POWER T/O. 92 PERCENT N2 & 28 DEGREES C OAT AT DAY. FOUND NR 1 ENGINE EGT INDICATOR READS 24-34 DEGREES HIGH. NO DEFECTS ON HARNESS R&R NR 1 EGT INICATOR 077-20-1, CK GOOD WITH TEST SET, ENGINE RUN REQSDR RRXA010062Floor Panel · damagedUPPER DECK CARGO FLOOR AT STA 781, 30 AND TO THE RT HAS A HOLE. REPAIRED GOUGE IN FLOOR PANEL IAW DC-8 SRM 53-2-3 FIG 6.SDR RRXA002749Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON FWD SIDE OF FRAME AT STA 20 AT CUSP LINE RT SIDE OF CABIN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRSDR RRXA002719Nut Plate · missingDURING A MAINTENANCE VISIT FOUND A BROKEN NUT PLATE ON THE RIGHT O/B SLOT UPPER SIDE SCREW AT STA XS 515, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW EO NR 00-107 WITH APPROVED 8SDR RRXA002720Link · damagedDURING A MAINTENANCE VISIT FOUND THAT THE FLAP LINK SUPPORT (CANOE FITTING) NEEDS TO BE REPLACED AT STA XW 219.498, 339.723 & 97.906 IAW DC-8 MM 27-51-12 RIGHT SIDE PER S/B 27-260, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-SDR RRXA002718Retainer · misinstalledDURING A MAINTENANCE VISIT FOUND CANOE FITTING BOLT RETAINER INSTALLED ON WRONG SIDE OF FITTING AT STA 340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-107 WITH APPRSDR RRXA002750Bulkhead · damagedDURING A MAINTENANCE VISIT FOUND NUMEROUS PATCHES TO THE FWD LWR CARGO COMPT MID BULKHEAD, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-107 WITH APPROVED 8110-3 DATEDSDR RRXA002738Pressure Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CENTER WING AFT LT TOP PANEL AT STA 848.00 AND LBL 60 TO 58 INCHES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAISDR RRXA002699Skin · dentedDURING A MAINTENANCE VISIT FOUND A DENT TO THE RT. ELEVATOR L/E AT STA XE 120, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. ACCEPTABLE TO RETURN TO SERVICE IAW E.O. 00-107 WITH APPROVED 8110-3 DATED 6-19-00.SDR RRXA002740Drag Link · brokenDURING A MAINTENANCE VISIT FOUND THE ATTACHMENT LUG BROKEN OFF TOP OF RT MAIN LANDING GEAR DRAG LINK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-107 WITH ASDR RRXA002739Bracket · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SUPPORT BRACKET AT STA FS 857 AND LBL 47 LT MAIN W/W, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-107 WITHSDR RRXA002745Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE UPPER CARGO COMPT AT CUSP LINE AT STA 1240 LT XCW 64 INCHES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DSDR RRXA002717Skin · crackedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES AND SMALL CRACK TO THE RT WING CENTER LEADING EDGE O/B SLOT EDGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NSDR RRXA002755Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE BULKHEAD AFT SIDE ANGLE AT STA 70 AND L22R TO L25R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-107SDR RRXA002695Pressure Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LWR CENTER WING AREA/BOTTOM RT PLATE AND BOTTOM LT PLATE SCREWS AND BOLTS AT STA 700 - 781 AND L35L - L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRMSDR RRXA002659Skin · lightning strikeDURING A MAINTENANCE VISIT FOUND LIGHTENING STRIKE DAMAGE TO THE RT WING TIP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-1.SDR RRXA002762Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CIRCUMFERENTIAL FRAME AFT SIDE AT STA 1140 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-1SDR RRXA002692Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK 3 INCHES LONG ON THE LT WING CENTER LEADING EDGE T/E DOUBLER AT STA 339.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO SDR RRXA002716Skin · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE TO THE SURFACE 8 INCHES AFT OF L/E LWR ON THE RT WING L/E AT STA XW 336.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NSDR RRXA002698Skin · damagedDURING A MAINTENANCE VISIT FOUND A DIMPLED WASHER ON THE RT HORZ STAB I/B LEADING EDGE SCREW AT STA XFS 178.7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED PART IAW EO NR 00-107 WITH APPROSDR RRXA002694Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE UNDER PANEL SPACERS ON THE LOWER CENTER WING AREA EXTERNAL AT STA 680 - 700 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTSDR RRXA002774Skin · looseDURING A MAINTENANCE VISIT FOUND ABOUT 75 RIVETS LOOSE AND PULLING ON O/B REVERSER OUTSIDE SKIN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-107 WITH APPRSDR RRXA002760Frame · damagedDURING A MAINTENANCE VISIT FOUND A HOLE IN THE UPPER FLANGE AT STA 1440 ABOVE L34L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-107 WITH APPROVED 8110-3 DSDR RRXA002743Plate · gougedDURING A MAINTENANCE VISIT FOUND A DENTED/GOUGED B PIT KICK PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 53-2-0 AND 51-1-20D.SDR RRXA002742Skin · damagedDURING A MAINTENANCE VISIT FOUND SHEARED EXTERIOR FASTENERS AT STA 305 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-107 WITH APPROVED 8110-3 DATED 5-3-00.SDR RRXA002741Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT UPPER T/E FLAP WELL FITTING AT STA XW-47, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-107 WITH APPROVEDSDR RRXA002713Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND ELONGATED HOLES TO THE CAN''T PRESS WEB PANEL AT STA 508 AND XCW 463, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8SDR RRXA002704Finger Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER DOUBLER AND REINFORCEMENT BRACKET AT STA 8 TO -12-X59-Z-10 RT SIDE OF CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND SDR RRXA002689Fitting · damagedDURING A MAINTENANCE VISIT FOUND A BROKEN TAB AND GOUGED FITTING ON THE 508 CAN''T WEB SUPPORT ATTACHMENT FITTING TO FRONT SPAR LOWER ATTACHMENT AT STA XCW 463, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-SDR RRXA002688Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND HOLES ELONGATED ON THE 508 CAN''T PRESSURE WEB PANEL AT STA XCW 463, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NRSDR RRXA002665Skin · damagedDURING A MAINTENANCE VISIT FOUND I/B EDGE SKIN BROKEN OFF WHERE FLIGHT SPOILER RETRACTS DOWN ON THE LT UPPER TRAILING SURFACE O/B AT STA 340 AT XRS 367, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FASDR RRXA002655Doubler · damagedDURING A MAINTENANCE VISIT FOUND A PATCH REPAIR THAT IS TORN NEAR SEAL ON THE LT MLG DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-1-21A, SDR RRXA002775Fairing · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ABOUT 2 INCHES LONG ON THE O/B REV TOP FAIRING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-107 WITH APPROVED 8110-3 DATED 6-7SDR RRXA002767Plate · gougedDURING A MAINTENANCE VISIT FOUND SEVERAL DENTS/GOUGES AROUND D PIT DOOR EXTERNAL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 AND 51-1-21.SDR RRXA002715Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CANOE FITTING ON THE RT WING AT STA 410, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8 AND EO NR 00-107 WITH APPROVED 8110-3 DATED 6-6-00. (CORROSDR RRXA002710Vane · damagedDURING A MAINTENANCE VISIT FOUND ENLARGED SCREW HOLES ON THE NR 2 RT FLAP VANE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-3-2 AND EO NR 00-107 WITH APPROVED 8110-SDR RRXA002690Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CANOE FITTING AT STA 410 LT WING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8 AND EO NR 00-107 WITH APPROVED 8110-3 DATED 6-6-00. (CORROSION DASDR RRXA002776Skin · cutDURING A MAINTENANCE VISIT FOUND SEVERAL CUTS IN NR 4 ENG O/B T/R INTER RING COWL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-107 WITH APPROVED 8110-3 DATESDR RRXA002714Skin · damagedDURING A MAINTENANCE VISIT FOUND OVERSIZED ATTACH HOLES TO THE STUB WING OVER NR 3 ENG O/B UPPER SURFACE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-107 WITH APPROVEDSDR RRXA002707Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED NR 11 RIB ON THE RT WING NR 3 STUB LWR LT RIB ANGLE AT STA XS 246, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-SDR RRXA002691Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SCREW HOLE 33 INCHES FROM LEADING FROM SPAR LWR, ON LT CENTER SECTION L/E AT STA 520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALSDR RRXA002662Skin · damagedDURING A MAINTENANCE VISIT FOUND LOOSE SCREWS ON THE LEFT O/B SLOT L/E AT STA 520 33 INCHES FROM FRONT SPAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-1SDR RRXA002656Panel · bulgedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE T/E UPPER SURFACE AT STA XE 245, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21 AND EO NR 00-107 WITH APPROSDR RRXA002759Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE TOP OF CIRCUMFERENTIAL FRAME AT STA 1400 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-SDR RRXA002752Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FWD LWR CARGO BILGE AT STA 350 AND L35R LT SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2SDR RRXA002726Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK THROUGH UNDER GUSSET ON THE NR 11 LOWER RIB ON THE RT WING L/E MIDDLE SECTION AT STA XFS 350, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTASDR RRXA002701Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND CRACK TO LONGERON 31R AT STA 8 TO -67, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PART IAW DC-8 SRM 51-1-0 AND 51-1-2SDR RRXA002790Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE INSIDE LONGERON UNDER CIRCUMFERENTIAL FRAME AT STA 600 AND L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA002770Frame · brokenDURING A MAINTENANCE VISIT FOUND A BROKEN FRAME AND SEAT TRACK AT STA 240 3RD SEAT TRACK FROM LT SIDE OF CABIN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 0SDR RRXA002766Rib · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE TO THE LT SIDE L2 DOOR LWR RIB FWD NUT PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-107 WITH APPROVED 8110-3
Back to N8084U, cancelled May 17, 2006