Pratt & Whitney Canada PW150A
Service difficulty reports · 3,094
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QXEA2012081700824Seat Track · corrodedSEAT TRACK NR 9 HAS CORROSION JUST FWD OF STA X783. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW RD 8/4-53-884. REMOVED SEAT TRACK NR9 IAW SRM 51-42-05-02-01, 51-41-05-00-01 AND SRM 51-40-15-02-01. MATCH DRILL REPLACEMENT SEAT TRACK NR 9 IAW SRM 51-40-07-0SDR QXEA2012081700849Frame · corrodedFRAME X258, FLANGES BETWEEN STRS 27P-33 AND AT STR 24P, BUBBLING PAINT/PROBABLE CORROSION. REMOVED RIVETS, PAINT AND PRIMER IAW SRM 51-42-05-02-01 AND 51-26-10-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .027", CONFIRMED AFFECTESDR QXEA2012081700850Frame · corrodedFRAME X604, FLANGES BETWEEN STRS 29S-32S BUBBLING PAINT/PROBABLE CORROSION. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED RIVETS AS NECESSARY, BLENDED CORROSION IAW RD 8/4-53-2344. REMOVED UPPER FRAME FLANGE IAW SRM 51-42-05-02-01 AND BLENDED CORROSION FROM SDR QXEA2012081700859Seat Track · corrodedSEAT TRACK NR 24, MULTIPLE AREAS OF DAMAGE/CORROSION. REMOVED CORROSION FROM TRACK AND FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2362. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801, PT 1. RESTORED SURFACE PROTECTION IAW RD 8/4-53-2362.SDR CA120822007Solenoid Valve · stuck(CAN) AFTER ARRIVAL ON THE GATE THE MAIN CABIN DOOR WAS VERY DIFFICULT TO OPEN. MAINTENANCE FOUND THAT THE ELECTRO PNEUMATIC SHUTOFF VALVE WAS STUCK IN THE CLOSED POSITION PREVENTING THE PNEUMATIC DOOR SEAL FROM DEFLATING. THE ELECTRO PNEUMATIC SHUTOFF VALVSDR CA120823005Gasket · leaking(CAN) DURING CRUISE, NR 1 HYD QTY INDICATED, 0 AND NR 1 ENGINE HYD PUMP, NR 1 HYD ISO VALVE, ROLL SPOILER INBD HYD, CAUTION LIGHTS ILLUMINATED. THE CREW CARRIED OUT NON-NORMAL PROCEDURE AND DECIDED TO DIVERT BASE. DURING APPROACH, NR 1 HYD QTY INDICATED ABOUTSDR CA120910010Bypass Valve · failed(CAN) DURING CLIMB AT FL 110, OIL TEMPERATURE ROSE UP TO 112C ON ENGINE NR 2. AFTER POWER REDUCTION BY 30 PERCENT, OIL TEMPERATURE STARTED TO DROP AFTER 3-4 MINUTES, AND AFTER 12 MINUTES IT DROPPED BELOW 107C. CREW DECIDED TO DIVERT FLIGHT, ON FL 160 WITH TSDR QXEA2012081600818Light · looseFLOURESCENT STRIP NEAR DOOR IS LOOSE. REMOVED LOOSE STRIP, CLEANED AREA AND REINSTALLED WITH NEW TAPE. RETURNED TO SERVICE.SDR QXEA2012081200816Stringer · corrodedSTRINGER 33, BETWEEN FRAMES X-39 TO X49.5, MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED, MAY INCLUDE FWD ATTACH FITTING AND SKIN ADJACENT TO STRINGER. REMOVED 10 FASTENERS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSIONSDR QXEA2012081600805Stanchion · corrodedSTANCHION AT FRAME X94.8 STRINGER 31P HAS BUBBLING PAINT & PROBABLE CORROSION. REMOVED STANCHION IAW SRM 51-42-05-02-01, FOUND CORROSION ON STANCHION NO REPAIRS ALLOWED IAW SRM 53-20-43-00-01. CLEANED ALODINED AND PRIMED IAW 51-21-10-02-01 AND 51-25-10-02-01SDR QXEA2012081600881Web · corrodedAFT BAGGAGE COMPARTMENT LT FLOOR WEB HAS AREAS OF CORROSION FROM STA X714.6 TO X783. REMOVED CORROSION IAW SRM 51-21-00-00-02. FLOOR WEB OUT OF LIMITS IAW SRM 53-40-43-02-01. REMOVED WEB IAW SRM 51-40-15-02-01 AND 51-42-05-02-01. MATCH DRILLED NEW WEB IAW SDR CA120817003Hose · chafed(CAN) DURING SCHEDULED MAINTENANCE, THE PITOT HOSE TO THE INTEGRATED STANDBY INSTRUMENT WAS FOUND CHAFING ON THE FWD OUTFLOW VALVE. THE PITOT HOSE WAS REPLACED. THE INSPECTION BEING CARRIED OUT IS AN IN-HOUSE TASK CARD TO SPECIFICALLY CHECK FOR THIS ISSUE ASSDR QXEA2012081500820Connector · failedAFTER TAKEOFF, THREE RED GEAR UNSAFE INDICATION LIGHTS. ACCOMPLISHED EMERGENCY GEAR EXTENSION IAW CHECKLIST, RETURNED TO FIELD AND LANDED UNEVENTFUL. DURING FUNCTIONAL TEST, NOSE WHEEL DID NOT CENTER FOR STEPS 4.A. (11)(5)- (U0, AMM 32-51-00-720-801. TOOKSDR QXEA2012081500806Stringer · corrodedSTRINGER 24P BETWEEN FRAMES X236 TO X373.1, MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED, MAY INCLUDE FWD ATTACH FITTING. REMOVED CORROSION IAW SRM 51-21-00-00-02. FOUND WITHIN LIMITS IAW RD 8/4-53-4670. APPLIED ALOSDR QXEA2012081500807Support Angle · corrodedCORROSION ON LT WEB SUPPORT ANGLES FWD/AFT AT STATION 747.602. REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-06-910-801 PT 1. MECHANICALLY MEASURED SUPPORT ANGLES, MIN REMAINING THICKNESS FOUND TO BE .046". MASDR QXEA2012081500813Seat Track · damagedSEAT TRACK NR 8 MULTIPLE AREAS OF DAMAGE/CORROSION. REMOVED NR 8 SEAT TRACK IAW SRM 51-42-05-02-01. FOUND SEAT TRACK DAMAGE TO BE OUT OF LIMITS IAW RD 8/4-53-884. MATCH DRILLED NEW SEAT TRACK IAW SRM 51-40-07-02-01. ALODINED, PRIMED HOLES IAW SRM 51-21-10-SDR QXEA2012081500905Support · corrodedCORROSION ON LT WEB SUPPORT BETWEEN STATIONS 763.602 ABOVE STRINGER 28P TOP/BOTTOM. REMOVED CORROSION IAW SRM 51-21-00-00-02. REMOVED NUTPLATE IAW SRM 51-42-05-02-01. MIN REMAINING THICKNESS .048, CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 SDR QXEA2012081400797Stringer Clip · corrodedSTRINGER CLIP, STRINGER 33 AT FRAME 49.5 BUBBLING PAINT PROBABLE CORROSION. REMOVED CLIP DUE TO CORROSION IAW SRM 51-42-05-02-01. MATCH DRILLED NEW CLIP IAW SRM 51-40-07-02-01. INSTALLED CLIP IAW SRM 51-42-05-02-01. APPLIED TOP COAT IAW AMM 51-25-31-370-80SDR QXEA2012081400798Stringer · corrodedSTRINGER 24S BETWEEN FRAMES X236 TO X373.1, MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED MAY INCLUDE FWD ATTACH FITTING. CLEANED IAW SRM 51-26-00-02-01. REMOVED 3 CORRODED RIVETS IAW SRM 51-40-07-02-01. INSTALLED RIVSDR QXEA2012081400799Stringer Clip · corrodedSTRINGER CLIP, STRINGER 24P AT FRAME X258, BUBBLING PAINT/PROBABLE CORROSION. REMOVED STRINGER CLIP IAW SRM 51-42-05-02-01. MATCH DRILLED NEW PART IAW SRM 51-40-07-02-01. INSTALLED STRINGER CLIP IAW SRM 51-42-05-02-01. CLEANED AREA, APPLIED PRIMER, ALUMINISDR QXEA2012081400801Frame · corrodedCORROSION ON FRAME -54.0 BETWEEN STR 29P AND 30P. REMOVED CORROSION IAW SRM 51-21-00-00-02. REMAINING THICKNESS NOTED .038 REF NTM 51-00-04-910-801 PT 1. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. DAMAGE AREA IS WITHIN LIMITS IAW RDSDR QXEA2012081400804Frame · corrodedFRAME X94.8, FLANGES BETWEEN STRINGERS 25P-33, BUBBLING PAINT PROBABLE CORROSION. REMOVED FRAME FLANGE FOM REF RD 8/4-53-017 AND REMOVED CORROSION IAW SRM 51-21-00-00-02. REMAINING THICKNESS .0395 REF NTM 51-00-04-910-801 PT 1. VERIFIED AREA CRACK FREE RESDR QXEA2012081400809Frame · corrodedFRAME X401, FLANGES BETWEEN STRINGERS 30S-33 CORRODED. BLENDED CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .057" CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND WITHIN LIMITS IAW RD 8SDR QXEA2012081400838Support Angle · corrodedCORROSION ON PULLEY SUPPORT ANGLES FWD OF STA 783.102 BTW STR 31P AND 29P. REMOVED CORROSION IAW SRM 51-21-00-00-02. CLEANED AREA IAW SRM 51-26-00-02-01. MIN REMAINING THICKNESS NOTED .036" CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-04-910-801 PT 1 ASDR QXEA2012081400867Stringer · corrodedSTRINGER 25S BETWEEN FRAMES X236 TO X373.1 MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED. REMOVED RIVETS IAW SRM 51-42-05-02-01. CLEANED AREA IAW SRM 51-26-00-02-03. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED ASDR QXEA2012081300786Lamp · inoperativeEMERGENCY LIGHT SWITCH ON, FORWARD F/A CONTROL PANEL IS NOT ILLUMINATING. RELAMPED, OPS CHECK GOOD. NO DEFECTS NOTED. RETURNED TO SERVICE.SDR QXEA2012081300794Support Channel · corrodedCORROSION ON FORWARD WARDROBE INBD CHANNEL JUST FWD OF FWD PAX DOOR. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .045", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 AND51-00-06-910-801 PT 1. REMOVED FLOOR SUPPORT CHANNELSDR QXEA2012081300897Stringer · corrodedSTRINGER 25S, BETWEEN FRAMES X236 TO X373.1 MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED. REMOVED RIVETS AS NECESSARY IAW SRM 51-42-05-02-01. CLEANED AREA IAW SRM 51-26-00-02-03. NO CORROSION NOTED. INSTALLED RIVETSSDR QXEA20120813Stanchion · corrodedFOUND CORROSION ON STANCHION MATING SURFACE AT STA 1.00 AND STR 31P. STANCHION HAS NO REPAIRS ALLOWED IAW SRM 53-20-43-00-01 AND IS OUT OF LIMITS. REMOVED STANCHION IAW SRM 51-42-05-02-01, MATCH DRILLED NEW STANCHION IAW SRM 51-40-07-02-01. INSTALLED STANCHSDR QXEA2012081200802Stringer · corrodedSTRINGER 28S BETWEEN FRAMES X-39 TO 49.5, MULTIPLE AREAS OF CORROSION. REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED BLENDED AREA CRACK FREE, MIN REMAINING THICKNESS .038 REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-SDR QXEA2012081200810Frame · corrodedFRAME X1.0, 4 IN ABOVE STRINGER 26S, FLOOR SUPPORT BEAM CORRODED. CLEANED FRAME IAW SRM 51-26-10-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .045" CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910SDR QXEA2012081100787Shuttle Valve · inoperativeSPONGY BRAKES. BRAKING IS EQUAL, NO PULLING LT OR RT. BLED ALL FOUR BRAKES WITH MAIN BRAKE SYSTEM IAW AMM TASK 32-42-00-870-801. DURING BLEED PROCESS, FOUND NR 2 FUSE /SHUTTLE VALVE APPEARED TO BE INOPERATIVE. REPLACED NR 2 BRAKE FUSE /SHUTTLE VALVE IAW AMSDR QXEA2012081100800Bypass Valve · malfunctionedON CLIMB OUT, NR 1 OIL TEMP CLIMBED TO 113 FOLLOWED HIGH OIL TEMP CHECKLIST AND REDUCED TORQUE BY 20 PERCENT AND LATER TEMP REDUCED TO 107 AND BELOW. ALL OTHER LIMITATIONS WERE NOT EXCEEDED. RETURNED TO FIELD. LANDING UNEVENTFUL. INTERROGATED CDS, FOUND NO FASDR QXEA2012081000788Light · odorF/A (B) REPORTS AN ELECTRICAL ODOR IN THE AFT GALLEY AFTER BOARDING PASSANGERS COMPLETE. AFT PAX DOOR CLOSED AND LOCKED. FOUND SOURCE TO BE THE AFT CARGO COMPARTMENT LIGHTS.SDR QXEA2012081000783Seat Track · damagedSEAT TRACK NR 25 MULTIPLE AREAS OF DAMAGE/CORROSION. BLENDED TO REMOVE CORROSION IAW RD 8/4-53-884. FOUND WITHIN LIMITS OF RD 8/4-53-884 AND RD 8/4-53-2362. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. RESTORED SURFACE PROTECTION IAW RSDR QXEA2012081000793Seat Track · damagedSEAT TRACK NR 22 HAS MULTIPLE AREAS OF DAMAGE/CORROSION. REMOVED CORROSION, FOUND ALL BLENDS TO BE WITHIN LIMITS IAW RD 8/4-53-2362, CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-06-910-801 PT 1. RESTORED SURFACE PROTECTION PER RD 8/4-53-2362.SDR QXEA2012081000795Stringer Clip · corrodedSTRINGER CLIP, STRINGER 24S AT FRAME X489.5 BUBBLING PAINT PROBABLE CORROSION. REMOVED STR CLIP IAW SRM 51-40-07-02-01. MATCH DRILLED NEW STR CLIP IAW SRM 51-40-07-02-01. INSTALLED STR CLIP IAW SRM 51-42-05-02-01. PAINTED STR CLIP REF SRM 51-25-15-02-01. SDR QXEA2012080900789Light · malfunctionedON POWERING ACFT DOWN EMERGENCY LIGHTS ALL ILLUMINATED WITH SWITCH IN "OFF" POSITION. ACFT POWERED UP, GROUND CREW NOTIFIED TO NOT POWER DOWN ACFT. CYCLED F/A EMERGENCY LIGHTS CONTROL SWITCH ON & OFF. EMERGENCY LIGHTS DISARMED CAUTION LIGHT NOW ILLUMINATED.SDR QXEA2012080900790Unknown · odorOIL ODOR FROM VENTS ON FLT DECK, WITH ENGINES AT REDUCED POWER. ODOR CAME FROM VENTS AFTER REDUCING THROUGH 50 PERCENT TORQUE FOR APPROACH. NO SMOKE WAS APPEARENT. COMPLIED WITH ENGINE RUNS AND BOROSCOPE INSPECTIONS, FINDING NO EVIDENCE OF OIL OR DISCREPANCSDR QXEA2012080900777Seat Track · corrodedSEAT TRACK 19 HAS AREAS OF CORROSION FORWARD OF STA 428.5. REMOVED CORROSION IAW RD 8/4-53-884. FOUND SEAT TRACK WITHIN LIMITS IAW RD 8/4-53-884 AND RD 8/4-53-4676. CONFIRMED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. RESTORED SURFACE PROTECTION IAW RDSDR QXEA2012080900778Seat Track · corrodedSEAT TRACK 19 HAS AREAS OF CORROSION AFT OF STA 428.5. REMOVED CORROSION IAW RD 8/4-53-884. SEAT TRACK FOUND TO BE IN LIMITS IAW RD 8/4-53-4676. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. RESTORED SURFACE PROTECTION IAW RD 8/4-53-884SDR QXEA2012080900779Seat Track · corrodedSEAT TRACK 2 HAS AREAS OF CORROSION FOWARD OF STA 428.5. REMOVED CORROSION IAW RD 8/4-53-884. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. AFTER BLEND OUT OF DAMAGE, REMAINING THICKNESS FOUND IN LIMITS IAW RD 8/4-53-884. MAX MATERIAL RSDR QXEA2012080900780Seat Track · corrodedSEAT TRACK 2 HAS AREAS OF CORROSION AFT OF STA 428.5. REMOVED CORROSION IAW RD 8/4-53-884. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. AFTER BLEND OUT OF DAMAGE, MAX MATERIAL REMOVED .0275", REMAINING THICKNESS FOUND IN LIMITS IAW RD 8SDR QXEA2012080900782Seat Track · corrodedSEAT TRACK 3 HAS AREAS OF CORROSION. REMOVED CORROSION AND FOUND TO BE IN LIMITS IAW RD 8/4-53-884 AND RD 8/4-53-4666. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. RESTORED SURFACE PROTECTION IAW RD 8/4-53-4666. COMPLIED WITH TASK CARD SDR QXEA2012080900784Seat Track · corrodedSEAT TRACK 18 HAS AREAS OF CORROSION. REMOVED CORROSION IAW RD 8/4-53-884. BLENDED AREA FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-884. CONFIRMED AREA AFFECTED CRACK FREE REF NTM 51-00-06-910-801 PT 1. AREAS THAT EXCEEDED LIMITS OF RD 8/4-53-884 ARE IN LIMITSSDR QXEA2012080900785Seat Track · corrodedSEAT TRACK 1 HAS AREAS OF CORROSION. REMOVED CORROSION IAW RD 8/4-53-884, BLENDS FOUND TO BE OUT OF LIMITS. CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS THAT EXCEEDED LIMITS OF RD 8/4-53-884 ARE IN LIMITS IAW RD 8/4-53-46SDR QXEA2012080900791Seat Track · damagedSEAT TRACK NR 5, MULTIPLE AREAS OF DAMAGE/CORROSION. REMOVED CORROSION IAW 53-20-49-02-02. FOUND TO BE WITHIN LIMITS IAW SRM 53-20-49-02-02. CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-06-910-801 PT 1. RESTORED SURFACE PROTECTION IAW SRM 51-21-10-02-0SDR QXEA2012080900792Seat Track · damagedSEAT TRACK NR 6 HAS MULTIPLE AREAS OF DAMAGE/CORROSION. REMOVED CORROSION IAW RD 8/4-53-884, ALL BLENDS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-884. CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-06-910-801 PT 1. RESTORED SURFACE PROTECTION IAW RD 8/4-53-SDR QXEA2012080800773Stringer · corrodedSTRINGER 31S HAS CORROSION JUST AFT OF STA X783. CLEANED, REMOVED RIVETS AS NECESSARY AND REMOVED CORROSION IAW SRM 51-26-10-02-01, 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS .061", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 SDR QXEA2012080800803Stringer · corrodedSTRINGER 24P, BETWEEN FRAMES X373.1 TO X428.5, MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION. CLEANED REMOVED RIVETS AND REMOVED CORROSION IAW SRM 51-26-10-02-01, 51-42-05-02-01 AND SRM 51-21-00-00-02. CONFIRMED AREA IS CRACK FREE REF NTM 51-00-04-91
Back to Pratt & Whitney Canada PW150A