SDR QXEA2012082100846Frame · corrodedFRAME X-18.25 FLANGES BETWEEN STRS 30P-33, BUBBLING PAINT/PROBABLE CORROSION. REMOVED RIVETS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-01. MIN REMAINING THICKNESS NOTED .038" REF NTM 51-00-04-910-801 PT 1. PERFORMED THICKNESS GRID OSDR QXEA2012082100847Stringer · corrodedSTRINGER 31S, BETWEEN FRAMES X-39 TO X49.5 MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED MAY INCLUDE FWD ATTACH FITTING. CLEAN IAW SRM 51-26-10-02-01. REMOVED 10 RIVETS IAW SRM 51-42-05-02-01, AND REMOVED CORROSION IAWSDR QXEA2012082100853Stringer Clip · corrodedSTRINGER CLIP, STRINGER 32P AT FRAME X136, BUBBLING PAINT/PROBABLE CORROSION. STRINGER CLIP FOUND TO BE OUT OF LIMITS IAW SRM 53-20-15-00-01 ITEM 225, NO ALLOWABLE DAMAGE. REMOVED STRINGER CLIP IAW SRM 51-42-05-02-01. INSTALLED NEW STRINGER CLIP IAW SRM 51-SDR QXEA2012082100854Frame · corrodedFRAME X1.0 FROM RT INBD SEAT TRACK RUNNING OTBD, MULTIPLE CORRODING FASTENERS. CLEANED AREA IAW SRM 51-26-10-02-01. REMOVED RIVETS FOM. BLENDED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS .046", CONFIRMED AFFECTED AREA CRACSDR QXEA2012082100863Bulb · inoperativeF/A EMERGENCY LIGHT SWITCH NOT ILLUMINATED IN NORMAL POSITION. RELAMPED F/A EMERGENCY LIGHT SWITCH NORMAL LIGHTS. OP CHECKED GOOD. RETURNED TO SERVICE.SDR QXEA2012082100889Stringer · corrodedSTRINGER 28P BETWEEN FRAMES X-39 TO X49.5 MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED. REMOVED RIVETS, CLEANED AND REMOVED PAINT IAW SRM 51-42-05-02-01, 51-21-00-00-02 AND 51-26-00-02-01. REMAINING THICKNESS NOTED .048SDR QXEA2012082100904Stringer Clip · corrodedSTRINGER CLIP FRAME X-18.25 AND STRINGERS 26S, BUBBLING PAINT PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED. REMOVED CORROSION FROM STRINGER CLIP IAW SRM 51-21-00-00-02. STRINGER CLIP FOUND OUT OF LIMITS IAW SRM 53-20-15-00-01. MATCH DRILLED NEW STRSDR QXEA2012082100843Seat Track · damagedSEAT TRACK NR 18 MULTIPLE AREAS OF CORROSION OR OTHER DAMAGE. BLENDED DAMAGE IAW RD 8/4-53-884 AND SRM 51-21-00-00-02. BLENDING IS WITHIN LIMITS IAW RD 8/4-53-884. CONFIRMED AFFECTED AREAS CRACK FREE CONDITION REF NTM 51-00-06-910-801 PT 1. APPLIED SURFACE SDR QXEA2012082100974Frame · corrodedFRAME X136, FLANGES BETWEEN STRS 26P-33 BUBBLING PAINT PROBABLE CORROSION. REMOVED FASTENERS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .037" REF NTM 51-00-04-910-801 PT 1. MATERIAL LOSS FOUND OUT OSDR CA120823004Bypass Valve · failed(CAN) DURING FLIGHT, FL 120, OIL TEMPERATURE RAISED. AFTER 6 MIN OIL TEMP RAISED AGAIN EVEN BY REDUCING THE POWER SETTING INTO THE RED BAND. TEMPERATURE GREATER THEN 125 DEGREE C. THE CREW DECIDED TO SHUTDOWN THE ENGINE AND DECLARED EMERGENCY. TROUBLESHOOTINSDR QXEA2012082000825Access Panel · damagedLEFT WING FUEL ACCESS PANEL LANDING AT APPROX STA YW48.000 HAS A BOLT HOLE WITH EDGE DAMAGE. MEASURED DAMAGE AND FOUND OUT OF LIMITS IAW RD 8/4-57-526. CONFIRMED AFFECTED AREA CRACK FREE CONDITION REF NTM 51-00-05-250-801 PT 6. COMPLIED WITH REPAIR IAW RD 8/SDR QXEA2012082000826Arm · damagedFWD BAGGAGE DOOR, HINGE ARM HAS MULTIPLE AREAS OF CHAFE DAMAGE TO LOWER EDGE. SMOOTHED DAMAGE IAW SRM 51-14-00-02-04. NO LIMITS FOR DAMAGE TO HINGE, MAPPED FOR ENGINEERING. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. BLEND DAMAGE 4.4 SDR QXEA2012082000827Arm · damagedSERVICE DOOR HINGE ARM HAS CHAFE DAMAGE ON LOWER SURFACE. SMOOTHED DAMAGE IAW SRM 51-14-00-02-04. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-60-00. DAMAGE FOUND 1.1" BY .4" BY .030" DEEP AND IN LIMITS IAW RD 8/4-52-811. ALODINED, PRIMED AND PAINTED IAW SDR QXEA2012082000828Frame · corrodedFRAME X258, FLANGES BETWEEN STRS 25S-26S AND 28S-32S BUBBLING PAINT/PROBABLE CORROSION. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED 4 RIVETS, PAINT PRIMER AND CORROSION IAW SRM 51-42-05-02-01, AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .039" CONFIRMSDR QXEA2012082000829Stringer · corrodedSTRINGER 29S BETWEEN FRAMES X236 TO X373.1, MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED, MAY INCLUDE FWD ATTACH FITTING. CLEAN IAW SRM 51-26-10-02-01. REMOVED 35 CORRODED RIVETS IAW SRM 51-40-07-02-01. INSTALLED 35 SDR QXEA2012082000831Stanchion · corrodedFRAME X413 STANCHION AT STR 31S SHOWS CORROSION. REMOVED CORRODED STANCHION AND MATCH DRILLED NEW STANCHION REF SRM 51-42-05-02-01, 51-40-15-02-01 AND 51-40-07-02-01. INSTALLED NEW STANCHION IAW SRM 51-42-05-02-01. APPLIED PRIMER AND ALUMINIZED TOPCOAT IAW SDR QXEA2012082000832Cleat · corrodedCLEAT AT FRAME X32.4, STR 26P IS CORRODED. REMOVED CLEAT IAW SRM 51-42-05-02-01. CLEAT FOUND TO BE OUT OF LIMITS IAW SRM 51-14-00-00-01. MATCH DRILLED NEW CLEAT IAW SRM 51-40-07-02-01. INSTALLED CLEAT IAW SRM 51-42-05-02-01, 51-25-10-02-01 AND 51-25-15-02-SDR QXEA2012082000833Seat Track · corrodedRT INBD SEAT TRACK HAS CORROSION AT FR 401. BLENDED CORROSION ON RT INBD SEAT TRACK AT FR 401 IAW RD 8/4-53-884. BLEND FOUND IN LIMITS IAW RD WITH .020" MAX MATERIAL LOSS CENTER AND .013" MAX MATERIAL LOSS CLAW LUG. CONFIRMED AFFECTED AREAS CRACK FREE REF NSDR QXEA2012082000834Seat Track · corrodedSEAT TRACK NR 1, MULTIPLE AREAS OF CORROSION OR OTHER DAMAGE. BLENDED CORROSION OUT OF MULTIPLE AREAS ON SEAT TRACK NR 1 REF SRM 51-21-00-00-02. FOUND BLENDS WITHIN LIMITS IAW RD 8/4-53-884. CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-06-910-801 PT 1.SDR QXEA2012082000839Floor Support · corrodedFRAME X1.0 AND AFT CORRODED FLOOR SUPPORT CHANNEL JUST OTBD OF LT INBD SEAT TRACK. REMOVED OLD SHEAR PANEL IAW SRM 51-42-05-02-01. MATCH DRILLED NEW PART IAW SRM 51-40-07-02-01. INSTALLED NEW SHEAR PANEL IAW SRM 51-42-05-02-01.SDR QXEA2012082000840Frame · corrodedFRAME X1.0 FLANGES BETWEEN STRS 30S-33 BUBBLING PAINT/PROBABLE CORROSION. REMOVED FOUR RIVETS AND BLENDED CORROSION IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS NOTED .045" REF NTM 51-00-04-910-801 PT 1. VERIFIED BLENDED AREAS TO BE CRSDR QXEA2012082000841Floorbeam · corrodedFRAME X-18.25 AND CENTERLINE AT FLOORBOARDS, FLOORBOARD ATTACH T AND FASTENERS, CORRODED. REMOVED FLOORBOARD ATTACH T, FOUND OUT OF LIMITS IAW SRM 51-42-05-02-01 AND 53-20-43-00-01. CORROSION LIMITED TO T BRACKET ONLY, MATCH DRILLED NEW BRACKET IAW SRM 51-40SDR QXEA2012082000842Seat Track · corrodedFRAMES X689 TO X714 L INBD SEAT TRACK FLOWING OBO HORIZ FLOOR WEB SHOWS MANY AREAS OF LIFTING PAINT/PROBABLE CORROSION SURFACE PROTECTION ISSUES. CLEANED AREA IAW SRM 51-26-10-02-01 AND 51-21-00-00-02. REMOVED CORROSION IAW SRM 51-21-00-00-01. MIN REMAININGSDR QXEA2012082000848Frame · corrodedCLEANED FRAME AND FLANGES IAW SRM 51-26-00-02-01. REMOVED RIVETS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. CORROSION FOUND OUT OF LIMITS IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .029", CONFIRMED AFFECTED AREA CRACKSDR QXEA2012082000852Stringer · corrodedSTRINGER 31S BETWEEN FRAMES X49.5 TO 236, MULTIPLE AREAS OF BUBBLING PAINT, PROBABLY CORROSION AND/OR SURFACE PROTECTION NEEDED, MAY INCLUDE FWD ATTACH ITEMS. CLEANED AREA IAW SRM 51-26-00-02-01, REMOVED CORROSION IAW SRM 51-21-00-02-01. STRINGER SPLICE FOUNSDR QXEA2012082000855Frame · corrodedFRAME X19.4 FLANGES BETWEEN STRS 32P-33, BUBBLING PAINT/PROBABLE CORROSION. CLEANED FLANGES IAW SRM 51-26-00-02-01. REMOVED FASTENERS AND CORROSION IAW RD 8/4-53-2344. FRAME FOUND TO BE OUT OF LIMTS IAW SRM 53-20-15-00-01. REMOVED FRAME SECTION AND INTERCOSSDR QXEA2012082100857Frame · corrodedFRAME X176 FLANGES BETWEEN STRS 26S-33 BUBBLING PAINT/PROBABLE CORROSION. REMOVED RESERVOIR TANK FOM IAW AMM 52-12-01-000-801. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED FASTENERS TO ACCESS CORROSION IAW 51-40-07-02-01. REMOVED CORROSION IAW SRM 51-21-00SDR QXEA2012082000866Flap System · malfunctionedFLAP POWER CAUTION WHEN SELECTING FLAPS TO 35 DEGREES. FLAPS STAYED AT 15 DEGREES. FOLLOWED EAC CHECKLIST, FLAP POWER CAUTION RETURNED. LANDING UNEVENTFUL. PERFORMED FIM TASK 27-50-00-810-802. FAULT NOTED AS CURRENT - ECU CONTINUOUS BIT. PERFORMED FIM TASK 27SDR QXEA2012082000885Stringer · corrodedSTRINGER 32P BETWEEN FRAMES X-39 TO X49.5, MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED. RMOVED RIVETS AS NECESSARY IAW SRM 51-42-05-02-01 AND CLEANED IAW SRM 51-21-00-00-02 AND 51-26-00-02-01. CORROSION LIMITED TO Z-JSDR QXEA2012082000892Seat Track · corrodedSEAT TRACK NR 16, MULTIPLE AREAS OF DAMAGE/CORROSION. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-884. REMOVED SEAT TRACK IAW SRM 51-41-05-00-01, 51-42-05-02-01. MATCH DRILLED NEW TRACK IAW SRM 51-40-07-02-01. INSTALLED SEAT TRACK 316 IAWSDR QXEA2012082000912Seat Track · corrodedSEAT TRACK NR 20 MULTIPLE AREAS OF CORROSION OR OTHER DAMAGE. BLENDED OUT DAMAGE IAW RD 8/4-53-884 AND FOUND WITHIN LIMITS OF RD 8/4-53-884. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. APPLIED SURFACE PROTECTION IAW RD 8/4-53-884.SDR QXEA2012082000913Seat Track · corrodedSEAT TRACK NR 3 MULTIPLE AREAS OF CORROSION OR OTHER DAMAGE. CLEANED AREA AND BLENDED OUT CORROSION IAW SRM 51-26-00-02-01 AND 51-21-00-00-02. BLENDS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-884. CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-06-910-801 PSDR QXEA2012082000978Arm · chafedSERVICE DOOR HINGE ARM HAS CHAFE DAMAGE ON LOWER SURFACE. SMOOTHED DAMAGE IAW SRM 51-14-00-02-04. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-60-00. DAMAGE FOUND TO BE 1.1" X .4" X .030" DEEP AND IN LIMITS IAW RD 8/4-52-811. ALODINED, PRIMED AND APPLIED SDR QXEA2012081500819Structure · crackedCRACKS IN LEFT OTBD FLAP T/E FORWARD ABOUT 8 INCHES. INSPECTED AREA NO CRACKS NOTED, FOUND MISSING SEALANT. REMOVED LOOSE SEALANT FROM SEAM APPLIED SEALANT AND ALLOWED TO CURE TO TACK FREE STATE, APPLIED SPEED TAPE IAW SL-51-001. LOCATED APPROX 36 INCHES INBSDR QXEA2012081900822Intercostal · corrodedCORROSION FOUND ON INTERCOSTAL BETWEEN STATIONS 1.000-19.500 ON STRINGER 28P. NO REPAIR ALLOWED TO INTERCOSTAL IAW SRM 53-20-17-00-01, REMOVED COOLING FAN SUPPORT STRUCTURE AND INTERCOSTAL IAW SRM 51-42-05-02-01. MATCH DRILLED NEW PARTS IAW SRM 51-40-07-02-0SDR QXEA2012081900823Angle · corrodedAFT BAGGAGE COMPARTMENT, LT REINFORCEMENT ANGLE AT BOTTOM OF STEP UP AT STA X783 HAS AREAS OF CORROSION. REMOVED 7 RIVETS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. NO REPAIRS ALLOWED IAW SRM 53-40-15-00-01. REMOVED DAMAGED ANGLE IAWSDR QXEA2012081900851Stringer · corrodedSTRINGER 29P BETWEEN FRAMES X-39 TO X49.5, MULTIPLE AREA OF BUBBLING PAINT, PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED, MAY INCLUDE FWD ATTACH FITTING. REMOVED DAMAGE SURFACE PROTECTION AND BUBBLING PAINT IAW SRM 51-26-00-02-03 AND 51-26-00-02-01. RSDR QXEA2012081900896Seat Track · corrodedSEAT TRACK NR 7 MULTIPLE AREAS OF DAMAGE/CORROSION. BLENDED OUT CORROSION IAW SRM 51-18-00-00-01, MEASURED AND FOUND DAMAGE TO BE OUT OF LIMITS IAW RD 8/4-53-884. REMOVED SEAT TRACK IAW SRM 51-42-05-02-01, MATCH DRILLED NEW TRACK IAW SRM 51-40-07-02-01. INSDR CA120820002Cable · frayed(CAN) DURING SCHEDULED INSPECTION OF THE EXPOSED AILERON CONTROL CABLES ALONG THE WING REAR SPAR TASK 000-27-900-705, A FRAYED CABLE WAS FOUND ON THE LT WING JUST OTBD OF BS YW-191.200. THE DAMAGE WAS FOUND TO BE BEYOND WEAR LIMITS. THE CABLE IS A .1250 DIAMSDR QXEA2012081800812Intercostal · corrodedCORROSION ON INTERCOSTAL INBD OF STR 30P APPROX 3 INCH FWD OF FR -54.00. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BESDR QXEA2012081800814Frame · corrodedFRAME 32.4 UPPER FLANGE IS CORRODED STR 30S -33. REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-4708. ALODINED, PRIMED AND APPLIED ALUMINIZED PAINT ANSDR QXEA2012081800817Frame · corrodedFRAME X32.4, FLANGES, BETWEEN STRS 30S - 33 BUBBLING PAINT/PROBABLE CORROSION. REMOVED 17 RIVETS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .029 REF NTM 51-00-04-910-801 PT 1 AND RD 8/4-53-4708. VERIFIED FRAMESDR QXEA2012081800821Fairing · dentedLEFT FWD WING TO FUSELAGE TOUCHDOWN FAIRING HAS MULTIPLE DENTS BETWEEN STATIONS X301.000 AND 341.000. DENTS FOUND TO EXCEED LIMITS OF RD 8/4-53-2231. CONFIRMED DENTS IN ALUMINUM PORTION OF FAIRING, CRACK FREE REF NTM 51-00-06-910-801 PT 1. INSPECTED COMPOSSDR QXEA2012081800830Threshold · corrodedAFT BAGGAGE COMPARTMENT THRESHOLD STRAP AT BS 763.602 HAS CORROSION. NO ALLOWABLE DAMAGE IN SRM, FOUND TO BE OUT OF LIMITS. REMOVED STRAP DOUBLER IAW SRM 51-42-05-02-01. MATCH DRILLED REPLACEMENT STRAP DOUBLER IAW SRM 51-40-07-02-01. INSTALLED THRESHOLD STSDR QXEA2012081800864Warning Message · multiple failAFTER STARTING NR 1 ENGINE, CONDITION LEVERS TO MAX. NR 1 PEC, NR 1 AC GENERATOR CAUTIONS ILLUMINATED, NR 1 PROPELLER FEATHERED ON ITS OWN. THE ED DISPLAYS A POWERPLANT MESSAGE. INTERROGATED CDS. FOUND FAULT CODES 130 AND 134 CH A AND B NR 1 ENGINE. COMPLIESDR CA120820003Skin · dented(CAN) AFTER LANDING, EVIDENCE OF A BIRD STRIKE TO THE LT WING L/E INBD SECTION WAS NOTICED. THERE WAS SOME DAMAGE TO THE L/E SO IT WAS REPLACED. L/E PN 85720220-003.SDR CA120822008Pump · failed(CAN) ON APPROACH, NR 1 HYDRAULIC CAUTION LIGHT ILLUMINATED ALONG WITH NR 1 HYDRAULIC FLUID LEVEL QUICKLY DROPPING FROM 75 PERCENT TO 70 PERCENT, 40 PERCENT. ON ARRIVAL ADDITIONAL REPORT OF NR 1 HYDRAULIC FLUID QTY UP 100 PERCENT, THEN QUICKLY DROPPING FROM 7SDR QXEA2012081700808Seat Track · damagedSEAT TRACK 17 HAS TOOLING DAMAGE AND CORROSION. REMOVED DAMAGE IAW RD 8/4-53-884. SEAT TRACK FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-884, MIN REMAINING THICKNESS .387". CONFIRMED AFFECTED ARE CRACK FREE REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND WISDR QXEA2012081700811Floor Support · corrodedCENTER LINE FLOORBOARD ATTACH TEE AND ASSOCIATED STRUCTURE AND HARDWARE AT FRAME X1.0 IS CORRODED. REMOVED CENTER LINE FLOORBOARD ATTACH T FOR REPLACEMENT IAW SRM 51-42-15-02-01. ATTACH T FOUND TO BE OUT OF LIMITS IAW SRM 53-20-43-00-01. CORROSION LIMITED TSDR QXEA2012081700815Stanchion · corrodedCORROSION MIGRATED TO STANCHION FROM FRAME 116.000 AT STRINGER 31S. FOUND STANCHION TO BE OUT OF LIMITS. REMOVED STANCHION IAW SRM 51-42-05-02-01. MATCH DRILLED NEW PART IAW SRM 51-40-07-02-01. TREATED AND PRIMED HOLES IAW SRM 51-21-10-02-01 AND SRM 51-25-1
Back to Pratt & Whitney Canada PW150A