SDR DLM88101278Light · inoperativeMX FOUND THE SEAT MOUNTED EMERGENCY LIGHT AT SEAT 30D TO BE INOPERATIVE. MX REPLACED THE LIGHT ASSY. AN OPS CHECK WAS PERFORMED AND THE ACFT WAS RETURNED TO SERVICE.SDR DLM88101277Wire Harness · brokenMX NOTICED THAT THE EMERGENCY LIGHT AT 14DE WAS FOUND TO BE INOPERATIVE. MX FOUND A BROKEN HARNESS AND INSTALLED A SPLICE. AN OPS CHECK WAS PERFORMED AND THE ACFT WAS RETURNED TO SERVICE.SDR DLM88101247Battery Pack · inoperativeMX FOUND THE EMERGENCY TRACK LIGHTS TO BE INOPERATIVE. MX REPLACED THE BATTERIES. AN OPS CHECK WAS PERFORMED AND THE ACFT WAS RETURNED TO SERVICE.SDR FDEA201005141731Skin · gougedGOUGES IN MCD INNER DOUBLER SKIN STA 620-640 STRINGERS 5L - 8L REMOVED INNER WEB SKIN IAW P-F SRM 51-30-2. FABRICATED INNER WEB SKIN FROM 2024T3 .125" DIM. 80" X 48" IAW P-F SRM 53-10-2. INSTALLED INNER WEB SKIN IAW P-F SRM 51-30-2.SDR DALA1011950998Skin · corrodedCORROSION ON FUSELAGE SKIN STA 1150-1154, BTW L29RT AND L29LT. REPAIR ACCOMPLISHED REPAIR IAW 481749-14 REV.SDR DLM88101230Structure · damagedVERTICAL STAB HOLES WORN ON LT SIDE CHORD COMMON TO L/E PANEL STRUCTURE WAS REPAIRED IAW ERA 481678-14.SDR DLM88101232Spar · damagedVERTICAL STAB FRONT SPAR UPPER RT CHORD HAD OVERSIZED HOLES AND WAS REPAIRED IAW ERA 482312-14.SDR DLM88101233Threshold · corrodedCTR CARGO THRESHOLD WAS CORRODED AND REPAIRED IAW ERA 482343-14.SDR DALA1011990998Structure · corrodedPITTING CORROSION INSIDE BARREL NUT BORE UPPER MID PLATE RT HORTZ STAB BOX. BORE OF NR 13 BARREL NUT HOLE CORRODED. REMOVED AND REPAIRED IAW ERA 481750-14 REV ORIG. (DLM88101402)SDR DLM88101241Wire Harness · disconnectedMX FOUND THE EMERGENCY LIGHT AT SEAT 29D TO BE INOPERATIVE. MX RECONNECTED THE HARNESS. AN OPS CHECK WAS PERFORMED AND THE ACFT WAS RETURNED TO SERVICE.SDR ABXR2010090700038Cargo Track · corrodedDURING A HEAVY MX VISIT, THE AFT LOWER CARGO SEAT TRACK (CARGO TRACK), UPPER OTBD EDGE ABOVE LONGERON 28 LT WAS FOUND CORRODED BEYOND LIMITS. FABRICATED REPAIR PARTS FROM 7075 T-6 0.050" AND HEAT TREATED REPAIR PIECED TO T-6 TEMPER. SPLICED IN NEW WECTION OF TSDR DLM88101115Frame · dentedDURING HMV FOUND A 1 INCH DENT AT STA 237 L-18-L ON EXISTING REPAIR. FOUND DENT IN REPAIR DOUBLER TO BE OUT OF LIMITS DUE TO CREASE. FOUND FORMER STA 237 L18L -17L DENTED AND BENT. REMOVED, OBTAINED AND INSTALLED NEW FORMER 9911524U3 IAW SRM 51-30-2, 51-30-5, SDR DLM88101125Fitting · leakingF/A REPORTED BOTH AFT SMOKE DET GOING AND HAZE IN CABIN. FOUND FITTING ON LT AUTOBRAKE MANIFOLD LEAKING. REPLACED O-RING ON FITTING. LK CKS GOOD. ALSO SEE ITEM 5 THIS LOG PAGE. ACFT OK FOR SERVICE.SDR DALA1011970998Skin · corrodedEXFOLIATION CORROSION ON FUS SKIN STA 579-587 BTW LONGS 30 AND 29 LT. REPAIR IAW SRM 53-04D FIG 12C.SDR DALA1011960998Door Frame · corrodedCORROSION LWR DOOR JAMB BEAM PREVIOUS REPAIR STA1155-1212. REPAIR WAS ACCOMPLISHED IAW SRM 53-05, FIG 123. (DLM88101399)SDR DLM88101122Power Supply · inoperativeDURING LAYOVER CHECK, MX FOUND AFT CABIN EMERGENCY LIGHTS INOP ROWS 30 AND AFT. MX REPLACED THE BATTERY PACK AND POWER SUPPLY FUSES FOR THE AFT CABIN EMERGENCY LIGHTS, WHICH WAS NO HELP. MX REPLACED THE AFT CABIN EMERGENCY LIGHT POWER SUPPLY. ALL EMERGENCY LSDR AALA20100223TUL02Controller · faultedIAD - INFLIGHT DFW-DCA. CREW REPORTED ANTI-SKID INOPERTAIVE LIGHT ILLUMINATED. FLIGHT DIVERTED IAD LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED ANTI-SKID CONTROLLER. SYSTEM GROUND CHECK NORMAL OPERATION.SDR DLM88100451Connector · brokenSEAT MOUNTED EMERGENCY ESCAPE LIGHT AT 25 DE INOP. FOUND CONNECTOR BROKEN ON PIGTAIL. RETERMINATED WIRE CKS GOOD.SDR DLM88100452Charger · inoperativeFOUND AISLE EMERGENCY LIGHT SECTION 4 INOP. R & R BATTERY CHARGER AT THE SAME LOCATION IAW AMM. CKS NORMAL.SDR DLM88092003Skin · crackedDURING HMV A CRACK WAS FOUND ON RT UPPER SKIN ON VERTICAL STABILIZER L/E CRACK WAS REPAIRED IAW ERA 478005-14 REV ORIG.SDR HSYA20091109Line · crackedDURING CLIMBOUT, CREW NOTICED TORQUE BEGIN FALLING. AFTER REACHING CRUISE ALTITUDE OF 3,500 MSL THE TORQUE STEADIED AT 975 FT LBS AND CREW DECLARED AN EMERGENCY DUE TO ENG LOSS OF POWER. FLIGHT LANDED AT 2250Z WITHOUT FURTHER INCIDENT. THE CREW REPORTED ITT SDR DLM88091636Tire · wornACFT PULLED TO RT DURING TO ROLL. ENGINES SPOOLED EVENLY- LOW SPEED ABORT AT APPROX 15KTS - RETURNED TO GATE. INSPECTED NOSE GEAR AND SPRAY DEFLECTOR AND TESTED STEERING AT GATE. NO TROUBLE FOUND, REMOVED AND REPLACED LT AND RT NOSE TIRES IAW AMM 32-40-02-SDR YYFA200900006Handset · inoperativeCOCKPIT PA HANDSET DOES NOT BROADCAST TO CABIN.SDR C8GA20090179Actuator · leakingDURING CLIMB OPERATION A TOTAL "A" HYD SYS FAILURE OCCURRED. THE ACFT RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. POST FLIGHT INSP WAS PERFORMED. THE NR 3 SLAT ACTUATOR INBD FITTING WAS CRACKED. REMOVED AND REPLACED THE NR 3 SLAT ACTUATOR, REMOVEDSDR AALA20090729DFW01Bulb · inoperativeDURING CLIMBOUT AT CLIMB POWER, LEFT ENGINE OIL TEMP REACHED 166 DEGREES. OIL QUANTITY & OIL PRESS NORMAL. SHUT LEFT ENGINE DOWN AND WAS SHUT DOWN FOR 18 MINS FLIGHT DURATION. ACCOMPLISHED CARDS 71-92-11 AND 71-91-11. REPLACED LEFT ENGINE OIL TEMP BULB, OPSDR CA090618008Angle · broken(CAN) ON ARRIVAL, BLOW-OUT PANEL NR 3302L WAS FOUND OPEN. THIS PANEL PROVIDES ACCESS TO THE RAM AIR DUCT. INSP OF AREA FOUND ANGLE PN 65-49573-23 BROKEN. THIS ALLOWED RAM AIR TO LEAK INTO THE PANEL AREA AND CAUSE PANEL NR 3302L TO BLOW OPEN.SDR DLM88090862Cusp Web · corrodedRT CUSP WEB STA 503 TO 598 CORRODED OUT OF LIMITS. REPAIRED BY REPLACEMENT IAW 51-30-02 ON AAR NR 246207.SDR C8GA20090001Valve · inoperativeSHORTLY AFTER TAKEOFF THE CAPTAIN'S RMI OFF FLAG WITH HDG LIGHT ON COMPARATOR. ACFT RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. POST FLIGHT INSP WAS PERFORMED. THE NR 2 COMPASS RACK AND RT FLUX VALVE WAS REMOVED AND REPLACED. OPS CHECK OF THE NR 2 SDR C8GA20080085Intercostal · brokenWHILE IN HEAVY MAINTENANCE PERFORMING INSPECTIONS IT WAS NOTED THAT THE INTERCOSTAL SKIN ATTACH FLANGE WAS BROKEN AT BS 950A - 950B STR 28L. REMOVED BROKEN INTERCOSTAL AND FABRICATED NEW. INSTALLED FABRICATED INTERCOSTAL IAW SRM 53-10-2 AND 51-20-1. NO OTHESDR C8GA20080067Stringer · corrodedWHILE IN HEAVY MX PERFORMING INSP IT WAS NOTED THAT STRINGER 29R WAS CORRODED UNDER BS 950E FRAME EXTENDING TO BS 1000. CORROSION AT STR. 29R WAS OUT OF LIMITS. CUT OUT DAMAGED STR 29R AT BS 950 TO 1006. INSTALLED NEW STRINGER P/N 65-56441-8. WORK PERFORMED IASDR C8GA20080070Stringer · corrodedWHILE IN HEAVY MX PERFORMING INSP, IT WAS NOTED THAT STRINGER 29L STA 950C - 1000 IS CORRODED. REMOVED AND REPLACED STRINGER 29L P/N 65-56441-7. INSTALLED STRINGER IAW SB 727-53-0179. NO OTHER DEFECTS WERE NOTED. ACFT WAS RETURNED TO SERVICE.SDR C8GA20080074Support Angle · corrodedWHILE IN HEAVY MX PERFORMING INSP IT WAS NOTED THAT THE SUPPORT ANGLE LOCATED ABOVE STRINGER 26R AT BS 558 HAS SURFACE CORROSION. REMOVED CORRODED SUPPORT ANGLE AND FABRICATED SUPPORT ANGLE FROM 7075 O -.040 INCH (9 INCHES X 4.5 INCHES) HEAT TREATED TO T6. INSSDR C8GA20080080Shear Tie · corrodedWHILE IN HEAVY MAINTENANCE PERFORMING INSPECTIONS IT WAS NOTED THAT SHEAR TIE LOCATED AT STATION 580 STRINGER 26R-27R WAS CORRODED. REMOVED DAMAGED SHEAR TIE. FABRICATED NEW SHEAR TIE FROM 7075-O .071 INCH (8 INCHES X 2 INCHES) HEAT TREATED TO T6. INSTALLED NESDR C8GA20080069Stringer · corrodedWHILE IN HEAVY MX PERFORMING INSP IT WAS NOTED THAT STRINGER 22L STA, 1183 ATTACH FITTING HAS EXFOLIATION CORROSION. REMOVED AND REPLACED ATTACH FITTING. PN 65-24276-29 IAW SRM 51-30-2. NO OTHER DEFECTS WERE NOTED. ACFT WAS RETURNED TO SERVICE.SDR C8GA20080075Angle · corrodedWHILE IN HEAVY MX PERFORMING INSP IT WAS NOTED THAT THE L-ANGLE LOCATED BETWEEN STRINGER 27L - 28L IS CORRODED AT STA 740. REMOVED CORRODED L-ANGLE AND FABRICATED NEW FROM 7075 O -.090" (10.6250 INCH X 7.6258 INCH)HEAT TREATED TO T6. INSTALLED (L) ANGLE. IAW DSDR C8GA20080076Angle · corrodedWHILE IN HEAVY MX, PERFORMING INSP IT WAS NOTED THAT AN L-ANGLE LOCATED AT STA 740 STR 27R-28R WAS CORRODED. REMOVED DAMAGED ANGLE AND FABRICATED NEW ANGLE FROM 7075-O .190 INCH (12 INCH X 10.5 INCH) HEAT TREATED TO T6. INSTALLED L-ANGLE IAW 727 DRAWING NR 65-SDR DHLA200800114Accessory Unit · failedON CLIMBOUT AT 300KIAS PASSING FL200 RED DOORS LIGHT ON FWD PANEL & NOSE GEAR DOOR LIGHT ON S/O'S PANEL ILLUMINATED. FELT HEAVY VIBRATION PERFORMED ABNORMAL PROCEDURE AFTER SLOWING TO 260KTS LIGHT WENT OUT /VIBRATION REMAINED. MX INSTRUCTED, CYCLE GEAR UPON SDR C8GA20080072Stringer · corrodedWHILE IN HEAVY MX PERFORMING INSP IT WAS NOTED THAT STRINGER 28L STA 492 HAD CORROSION. CUT OUT DAMAGE AT STA 492 FABRICATED NEW ANGLE SUPPORT FROM 7075 T6 18, .5 INCH, FABRICATED STRINGER REPAIR STA. 480 -510 FROM P/N BAC 1498-141 7075 T6, FABRICATED 2EA SPLSDR C8GA20080071Stringer · corrodedWHILE IN HEAVY MX PERFORMING INSP, IT WAS NOTED THAT STRINGER 26L STATION 540 - 560 IS CORRODED.
CUT OUT DAMAGE AT STA 533-550. FABRICATED STRINGER FROM BAC 1498-143 7075T6, 16 INCH, FABRICATED 2 EA SPLICE PLATES FROM BAC 1498-132 7075 T6, 13 INCHES INSTALLED SDR C8GA20080081Shear Tie · corrodedWHILE IN HEAVY MX PERFORMING INSP IT WAS NOTED THAT SHEAR TIE LOCATED AT STA 990 STRINGER 29R WAS CRACKED. REMOVED DAMAGED SHEAR TIE. FABRICATED NEW SHEAR TIE FROM 7075-O .063 INCH (4.380 INCH X 2 INCH) HEAT TREATED TO T6. INSTALLED NEW SHEAR TIE IAW 53-10-4, SDR C8GA20080066Stringer · corrodedWHILE IN HEAVY MX PERFORMING INSP IT WAS NOTED THAT RIVETS WERE PULLING THROUGH THE SKIN EXTERIOR AT BS 1010 STR 28R. CORROSION ON STR 28R TO BE OUT OF LIMITS. CUT OUT DAMAGED STR 28R AT B.S 1010 TO + 11.375. FABRICATED NEW STRINGER REPAIR SPLICE FROM BAC 1498SDR C8GA20080077Shear Tie · corrodedWHILE IN HEAVY MX PERFORMING INSP IT WAS NOTED THAT SHEAR TIE LOCATED AT STA 620 STRINGER 26L-27L WAS CORRODED. REMOVED DAMAGED SHEAR TIE. FABRICATED NEW SHEAR TIE FROM BAC 1506-1630 7075-T6 (6.75 INCHES) INSTALLED SHEAR TIE IAW 51-30-2, 53-10-2. NO OTHER DEFESDR C8GA20080078Shear Tie · corrodedWHILE IN HEAVY MX PERFORMING INSP IT WAS NOTED THAT SHEAR TIE LOCATED AT STA 640 STRINGER 26L-27L WAS CORRODED. REMOVED DAMAGED SHEAR TIE. FABRICATED NEW SHEAR TIE FROM BAC 1506-1630 7075-T6 (6.75 INCH) INSTALLED SHEAR TIE IAW 51-30-2, 53-10-2. NO OTHER DEFECTSDR C8GA20080079Shear Tie · corrodedWHILE IN HEAVY MX PERFORMING INSP IT WAS NOTED THAT SHEAR TIE LOCATED AT STA 660 STRINGER 26R-27R WAS CORRODED. REMOVED DAMAGED SHEAR TIE. FABRICATED NEW SHEAR TIE FROM BAC 1506-1630 7075-T6 (6.5 INCH) INSTALLED SHEAR TIE IAW 51-30-2, 51-10-2. NO OTHER DEFECTSSDR MEW2008F00000Battery Pack · inoperativeEMERGENCY LIGHTS ABOVE, ON COCKPIT CEILING ARE INOPERATIVE. REMOVED AND REPLACED BATTERY PACK. (K)SDR MWE2008F00027Smoke Detector · inoperativeRT LAVATORY SMOKE DETECTOR SYSTEM IS INOPERATIVE WHEN TEST SWITCH WAS ACTIVATED. AFTER RESETTING RELEVANT CIRCUIT BREAKER ONE TIME IN COCKPIT AND ACTIVATING TEST SWITCH AGAIN, ALL INDICATIONS ARE NORMAL. SMOKE DETECTOR SYSTEM IN RT LAVATORY IS FULLY OPERATIOSDR 2008FA0000515Inlet · crackedDURING SCHEDULED INSP, FOUND VERTICAL STABILIZER L/E AT HEAT EXCHANGER INLET IS CRACKED APPROX 6.5 INCHES LONG ON LT SIDE. FOUND TO BE OUT OF LIMITS IAW SRM 55-05 FIG 3. (K)SDR MWE2008F00022Oil System · leakingFAINT ODOR DETECTED AND RIGHT AFT LAVATORY SMOKE DETECTOR WENT OFF AND LIGHT GRAY SMOKE WAS VISUAL. FOUND THE OIL LEAK WAS NOT CLEANED ENOUGH FROM PREVIOUS ISSUE ON 7/25/2008, REMOVED AND REPLACED APU. (K)SDR MWE2008F00026Coalescer Bag · contaminatedFWD LAVATORY SMOKE DETECTOR WENT OFF AND THERE WAS VISUAL GRAY SMOKE IN CABIN AND COCKPIT. REMOVED AND REPLACED WATER SOCKS DUE TO OIL CONTAMINATION FROM NOTED APU OIL LEAK. (K)SDR C8G2008F00008Antenna · faultedAFTER TAKEOFF, THE RADAR WAS SPOKING AND WOULD NOT PAINT KNOWN BAD WEATHER. THE AC RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. POST FLIGHT INSP REVEALED THE RADAR ANTENNA AT FAULT. REMOVED AND REPLACED RADAR ANTENNA, PERFORMED OPS CHECKS GOOD.