SDR AMTA200301324Actuator · inoperativePASSENGER DOOR DOES NOT OPEN ELECTRICALLY, MECHANICALLY, OR MANUALLY. REMOVED AND REPLACED L1 DOOR ACTUATOR IAW MM 52-12-01. OK FOR FLIGHT.SDR 751PA0024Spring · failedL1, R1, AND L4 DOOR GIRT BAR LEAF SPRINGS FAILED INSPECTION IAW MM-7200-03-00917 AND PACE MO NR B757-52-21003. REPLACED LEAF SPRINGS IAW MM 25-66-14.SDR UPS03541389Pressure Switch · malfunctionedINSPECTION TYPE:N/A C HYD SYS PRESS EICAS MESSAGE IN FLIGHT. SYS PRESS LIGHT ON OVERHEAD P PANEL ILLUMINATED. PERFORMED TEST OF CENTER HYD SYS IAW B-757 FIM 29-11-00. OPS CHECK NORMAL. COULD NOT DUPLICATE FAILURE. CTR SYS CASE DRAIN MODULE SYS PRESS SWITCSDR AWXA200301198Gear · wornON TAKEOFF ROLL, THE CAPTS AIRSPEED IND FAILED. VMO AIRSPEED MACH FLAGS IN VIEW, & AIRSPEED POINTER OFF SCALE & INOP IND VIEW, REJECTED TAKEOFF BELOW 100 KTS. MAINT PERFORMED A BITE TEST OF LT ADC IAW BMM. R & INSP CONNECTOR TO CAPTS AIRSPEED IND, NO DEFECTS NSDR AWXA200301196Fan · failedON DEPARTURE OUT OF PHX EN ROUTE FOR DFW ELECTRICAL ODOR FILLED THE FLIGHT DECK, TURNED BACK & LANDED WITHOUT FURTHER EVENT. FLT ATTENDANT REPORTED A BURNING ELECTRICAL ODOR FROM SEAT ROW 27 AFT. MAINTENANCE INSPECTED BOTH FORWARD AND AFT EQUIPMENT CENTERS, NSDR AUS20031028Engine · malfunctioned(AUS) RT ENGINE FAILED TO ACHIEVE TAKEOFF POWER. THRUST SHORTFALL REQUIRED WAS 1.73 BUT ONLY 1.71 WAS ACHIEVED WITH ASSOCIATED EICAS MESSAGE RT ENGINE RPM LIMIT. TAKE OFF WAS ABORTED AT 110 KNOTS GROUND SPEED.SDR AUS20031019Bolt · sheared(AUS) NR 2 MAIN WHEEL ASSEMBLY TIE BOLT (1OFF) SHEARED AND MISSING.SDR AMTA200301250Skin · corrodedFUSELAGE SKIN CORRODED AT LOWER ATC ANTENNA MATING SURFACE. REPAIRED SKIN IAW MFG ER 03-3513.(K)SDR AALA20031075Fuel Line · damagedMIA - FLT 863 - EN ROUTE SJU-STL, AIRCRAFT DEVELOPED FUEL LEAK ON THE NR 1 ENGINE. DECLARED EMERGENCY SHUT DOWN ENGINE AND LANDED WITHOUT INCIDENT. INSPECTED AIRCRAFT FOR OVERWEIGHT LANDING. REPLACED THE FUEL LINE BETWEEN THE FUEL OIL COOLER AND THE HIGH PRSDR AWXA200301108Governor · faultyDURING TAKEOFF, PILOT REPORTED THAT THE NR 1 ENGINE WOULD NOT MAKE T/O POWER. MAINT R&R NR 1 ENGINE FUEL FLOW GOVERNOR & PERFORMED T/O POWER TEST NR 13 IAW BMM. OPERATIONAL CHECK GOOD. EVALUATION OF FUEL FLOW GOVERNOR CONFIRMED FAILURE OF UNIT. ROTARY FACE SSDR AUS20030993Controller · faulty(AUS) RT ENGINE STALLED. ENGINE MOVED INTO RED ZONE (115 PERCENT N1). INVESTIGATION FOUND VIGV CONTROLLER FAULTY. LT AND RT VIGV ACTUATORS ALSO FAULTY.SDR CALA0300542Skin · dentedINSPECTION FOUND LT FUSELAGE SKIN DENTED AT BS 730, STRINGER 16L. THE SKIN WAS REPAIRED IAW ECRA 5330-03281.SDR AMTA200301248Floorbeam · corrodedMAIN CABIN FLOORBEAM UPPER CHORD CORRODED. REPAIRED FLOORBEAM IAW ER033585.(K)SDR CALA0300537Skin · crackedINSPECTION FOUND AN 8 INCHES CRACK IN LT WING FIXED LEADING EDGE SKIN AT OSS 421-471. THE SKIN WAS REPAIRED IAW ECRA 5721-01010, REV. D.SDR CALA0300541Skin · corrodedINSPECTION FOUND RT I/B MAIN FLAP SKIN PANEL CORRODED ON LOWER SURFACE. REPAIRED SKIN IAW ECRA 5750-03811.SDR AWXA200301189Floor Panel · delaminatedLCQ - MAJOR REPAIR - DURING C-09 CHECK CABIN FLOOR PANEL N-2 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL IAW DWG 146N5330, AND INSTALLED INSERTS IAW AWA E.R. 19-5322-03267-SS1.SDR AWXA200301190Floor Panel · delaminatedLCQ - MAJOR REPAIR - DURING C-09 CHECK CABIN FLOOR PANEL K-4 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL IAW DWG 144N5330, AND INSTALLED INSERTS IAW AWA E.R. 19-5322-03267-SS1.SDR AWXA200301191Stringer · corrodedDURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND AROUND NUT PLATE HOLES ON FLOOR STRINGER IN AFT CARGO COMPARTMENT BS 1500 TO BS 1560, LBL 18 TO RBL 18. MAINTENANCE CUTOUT CORRODED AREAS OF FLOOR STRINGER BS 1500 TO BS 1560, LBL 18 TO RBL 18; FABRICATED RESDR AWXA200301192Stringer · corrodedDURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND AROUND NUT PLATE HOLES ON FLOOR STRINGER IN AFT CARGO COMPARTMENT BS 1280 TO BS 1360, LBL 18 TO RBL 20. MAINTENANCE CUTOUT CORRODED AREAS OF FLOOR STRINGER BS 1280 TO BS 1360, LBL 18 TO RBL 20; FABRICATED RESDR AWXA200301193Floor Panel · delaminatedDURING C-09 CHECK CABIN FLOOR PANEL M-5 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL IAW DWG 144N5330, AND INSTALLED INSERTS IAW AWA E.R. 19-5322-03267-SS1.SDR AWXA200301194Floor Panel · delaminatedDURING C-09 CHECK CABIN FLOOR PANEL T-3 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL IAW DWG 146N5750, AND INSTALLED INSERTS IAW AWA E.R. 19-5322-03267-SS1.SDR AWXA200301195Floor Panel · delaminatedDURING C-09 CHECK CABIN FLOOR PANEL K-3 WAS FOUND DELAMINATED BEYOND LIMITS. MAINTENANCE FABRICATED A NEW REPLACEMENT FLOOR PANEL IAW DWG 146N5330, AND INSTALLED INSERTS IAW AWA E.R. 19-5322-03267-SS1.SDR AMTA200301127Engine · vibrationNR 2 ENGINE INDICATES HIGH VIBS ON BOTH CHANNELS, VIBS ARE LOW SIDE AND FOLLOW THE THROTTLES. ENGINE VIBE ON TAKEOFF WERE 2.3 ON B-CHANNEL AND 2.4 ON A-CHANNEL. DURING CLIMB, VIBE DECREASED TO APPROX 1.5 BOTH CHANNEL. PERFORMED TRIM BALANCE PER M11-72-52. SDR AWXA200300979Pump · inoperativeON PUSH BACK AT GATE THE NR 2 ENGINE AUTO SHUTDOWN, RT ENGINE LOW PRESSURE FUEL PUMP DISPLAYED ON EICAS. MAINT TROUBLESHOT & REPLACED NR 2 ENGINE FUEL FLOW GOVERNER IAW T/C R5M73603, OPS CHECK GOOD IAW T/C F5M73601. REPLACED NR 2 ENGINE HIGH PRESSURE FUEL PUMPSDR AWXA200300975Limiter · inoperativeON TAKEOFF AT DFW EN ROUTE FOR PHX THE NR 1 ENGINE LIMITER LIGHT ILLUMINATED WITH EICAS MESSAGE LT ENGINE LIMITER DISPLAYED. NR 1 ENGINE WOULD NOT DEVELOP TAKEOFF THRUST, REJECTED TAKEOFF AND RETURNED TO BLOCK. MAINTENANCE REMOVED THE NR 1 ENGINE ELECTRONIC COSDR AALA20030824Wire · shortedFIRST CLASS GALLEY EMERGENCY LIGHTS INOPERATIVE. FOUND FORWARD LEFT LIGHT WIRES SHORTED. REPAIRED WIRES. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AMTA200301021Skin · gougedFUSELAGE SKIN HAS GOUGES AT CROWN. REPAIRED SKIN IAW ER/A 757-53R-5239.SDR CALA0300368Wire Harness · damagedINSPECTION FOUND FLOOR PROXIMITY LIGHT WIRE HARNESS DAMAGED IN SEVERAL PLACES BETWEEN ROWS 26-35. THE WIRE HARNESS WAS REPLACED IAW DRAWING ACM BR2013-P-757CO/-1/-2/-3.SDR USA2004F00020Switch · out of adjustENROUTE, WITH THE LEFT GENERATOR ON MEL FOR RT GENERATOR NOT PICKING UP THE LT GENERATOR LOAD, AND APU OPERATING, THE APU PERFORMED AN AUTO SHUTDOWN. FLIGHT DIVERTED TO PIT AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE LT GCU, AND SUBSEQUENTLSDR AWXA200300631Governor · inoperativeON CLIMB OUT, NR 1 ENG WAS UNABLE TO MAINTAIN FULL CLIMB POWER, THRUST LEVERS SPLIT APPROX 5 INCHES, NR 2 ENG WAS ABLE TO MAINTAIN FULL CLIMB POWER, NR 1 ENG FULL FWD AGAINST STOPS. CLIMB WAS 1.54, NR 1 ENG INDICATED 1.44, FL 230. ENG LIMITER INOP LIGHT ILLUMISDR AWXA200300326Bleed Valve · failedON TAKEOFF FROM PHX EN ROUTE FOR LAX AS THROTTLES ADVANCED HEARD A LOUD BANG, REJECTED TAKEOFF DUE TO POSSIBLE NR 2 ENGINE COMPRESSOR STALL. PAX ALSO REPORTED SEEING FLAMES COMING OUT REAR OF ENGINE. MAINT PERFORMED ENGINE SURGE PROCEDURES AND BORESCOPED THE NSDR AUS20030332Blocker Door · damaged(AUS) NR 2 ENGINE THRUST REVERSER DAMAGED. INSPECTION FOUND THREE BLOCKER DOORS AT THE 8 O'CLOCK AND 9 O'CLOCK POSITIONS DAMAGED OR MISSING AND THE SHROUD ON THE PIPE CLUSTER AT THE 6 O'CLOCK POSITION MISSING.SDR USAABB03034Battery · dischargedFOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS, 1,4, 6 AND 9, INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES.SDR USAABB03033Light · inoperativeFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 1, INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY.SDR USAABB03030Battery Pack · dischargedFOUND EVACUATION LIGHT AT L3 DOOR, INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK.SDR USAABB03027Battery · dischargedFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 22, INOPERATIVE. MAINTENANCE REPLACED THE BATTERY.SDR USAABB03028Battery · dischargedFOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 23, INOPERATIVE.SDR AWXA200300128Floorbeam · corrodedMAJOR REPAIR, DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND ON A MAIN CABIN FLOORBEAM AT BS 1640, BS 0 TO LBL 5. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS OUT OF LIMITS; REMOVED EXISTING REPAIR FROM FORWARD SIDE OF FLOORBEAM AND TRIMMED OUT SDR AWXA200300131Floor Support · corrodedMAJOR REPAIR - DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND AT SCREW HOLE ON THE AFT CARGO COMPARTMENT FLOOR SUPPORT BS 1340, WL 148, RBL 2, STR 29 R/H. MAINTENANCE REMOVED CORRODED SECTION OF FLOOR SUPPORT BS 1340, WL 148, RBL 2, STR 29 RIGHT; FABRICATSDR AMTA200300196Doubler · corrodedAFT FUSELAGE SECT, INTERNAL DOUBLER HAS CORROSION AFT OF C2 DOOR CUT OUT, STA 1625 BETWEEN STR 16, 17. REPAIRED CORROSION DAMAGE IAW EAR.SDR HN62003F00000Cable · chafedNR 2 ENGINE GENERATOR FEEDER CABLES ARE CHAFING ON NR 6 SLAT INBOARD AUXILLARY TRACK. MOUNT PLATE FOR CLAMP IS MISPOSITIONED BELOW AUXILLARY TRACK. THERE ARE 2 POSITIONS FOR THE MOUNT PLATE, IN THE UPPER POSITION THE AUXILLARY TRACK CHAFES THE FEEDER CABLE. SDR 2003F00097Panel · inoperativeEVAC WARNING PANEL AT L1 DOOR HAS NO TONE DURING TEST. REMOVED AND REPLACED EVAC WARNING PANEL AT L1 DOOR.SDR 2003F00090Gcu · failed(ORIG-CLOSED) FLT 431. ON TAKEOFF ROLL BELOW 40 KTS, RT GENERATOR TRIPPED OFF. AIRCRAFT RETURNED TO GATE. MAINTENANCE REMOVED AND REPLACED THE RT GCU IAW MM. PERFORMED GENERATOR CONTROL ADJUSTMENT AND TEST IAW AMM OPERATIONAL CHECKS NORMAL.SDR 2003F00095Wire · loose(ORIG-CLOSED) DURING SCHEDULED MAINTENANCE EGRESS LIGHTING INOPERATIVE FROM ROWS 14 THROUGH 21. MAINTENANCE FOUND LOOSE WIRE AND RESECURED THE WIRE. EGRESS LIGHTING OPERATIONAL CHECK NORMAL.SDR 2003F00072Connector · inoperativeEVAC HORN AT L1 DOOR DOES NOT SOUND DURING TEST. RESEATED CONNECTOR PLUG ON EVAC BOX AT L1 AS REQUIRED.SDR 2003F00078Light · inoperativeEMERGENCY LIGHTING AT FORWARD GALLEY AND ROW 2HJK INOPERATIVE. REMOVED AND REPLACED LEAD ASSEMBLY AT SEAT 2 HJK FROM WALL TO EGRESS LITE.SDR 2003F00074Light · inoperativeEGRESS PATHWAY LIGHTING AT ROW 1-5 RIGHT, INOPERATIVE INCLUDING FORWARD GALLEY. REMOVED MOISTURE AND CLEANED CONTACTS ON EGRESS PATHWAY LIGHTING ROW 5 THRU FORWARD GALLEY RIGHT SIDE.SDR 2003F00075Lamp · inoperativeEGRESS PATHWAY LIGHTING AT ROW 1 LT INOPERATIVE. REPLACED MISSING EGRESS PATHWAY LIGHTING AT ROW 1 L/H AS REQUIRED.SDR 2003F00093Wire · disconnected(ORIG-CLOSED) DURING SCEDULED MAINTENANCE EMERGENCY EGRESS LIGHTS AT ROW 38 INOPERATIVE. MAINTENANCE RECONNECTED WIRE AT ROW 38 EGRESS LIGHTS ASSEMBLY. OPERATIONAL CHECK NORMAL.SDR 2003F00094Wire · disconnected(ORIG-CLOSED) DURING SCHEDULED MAINTENANCE EMERGENCY EGRESS LIGHTS AT ROW 29 INOPERATIVE. MAINTENANCE RECONNECTED WIRE AT EGRESS LIGHT ASSEMBLY ROW 29. OPERATIONAL CHECKS GOOD.
Back to Rolls-Royce RB-211 series