JASC 2150

Service difficulty reports · 12,393

Reports filed under 2150 · Cabin Cooling System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2150'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20150329009Control Valve · faultyAIR INTERRUPT, RETURNED & EMER DECLARED. LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB FLIGHT ATTENDANTS REPORTED VISUAL SMOKE IN CABIN & FLIGHT CREW OBSERVED, R ENG BLEED OFF, EICAS MSG DISPLAYED INTERMITTENTLY. ACCOMPLISHED WC 05-96-70 & PACK BURMar 29, 2015 · N39365 · Boeing 767323SDR ASAA2015032911163Control Valve · malfunctionedRIGHT PACK LIGHT ILLUMINATED ON CLIMBOUT. IAW QRH 2.7 LIGHT EXTINGUISHES WHEN MASTER CAUTION SYSTEM IS RESET. ACFT GROUNDED. BITE TEST ON NR 2 PACK, ZONE TEMP CONTROLLER REF AMM TASK 21-61-00 SHOWS NUMEROUS RT TCV FAULTS. REPLACED RT PACK TCV 2,V141, REF AMMar 29, 2015 · N403AS · Boeing 737990ERSDR ASAA2015032811143Warning Light · false activationON CHECKLIST RECALL, OBSERVED "PACK" ANNUNCIATOR LIGHT. ACCOMPLISHED AIR SYS PACK LIGHT QRH, PG-2.7 PROCEDURE. AFTER STEP 2- BOTH PACK LIGHTS REMAINED EXTINGUISHED. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONT BITE TEST. PREVIOUS FLT SHOWED RT PACK TCV FAMar 28, 2015 · N403AS · Boeing 737990ERSDR ASAA2015032811139Control Valve · failedLEFT PACK LIGHT ILLUMINATED WITH RECALL EXTINGUISHES ON RESET. ACFT GROUNDED. INSPECTED FAN BYPASS CHECK VALVE ON LT PACK PRIMARY PLENUM/DIFUSER ASSY FOR OPERATION AND SECURITY. BYPASS CHECK VALVE CHECK IS NORMAL. ACCOMPLISHED BITE PROCEDURE OF NR 1 PACK/ZOMar 28, 2015 · N413AS · Boeing 737990ERSDR ASAA2015032711142Warning Light · false activationON TAXI OUT, RT PACK LIGHT ILLUMINATED, NOT DURING RECALL, TRIP RESET DID NOT EXTINGUISH LIGHT. ACFT GROUNDED. ACCOMPLISH FIM 21-62, TASK 801 NO FAULTS FOUND ALL TEST PASS NO PACK LIGHT ILLUMINATED AT COCKPIT OR ON RECALL. OK FOR SERVICE.Mar 27, 2015 · N403AS · Boeing 737990ERSDR GLBA2015033000508Acm · wornPILOT REPORTED THAT THE PRESSURIZATION OPERATIONS CHECKED GOOD DURING RUN-UP, UPON CLIMB PRESSURIZED TO APPROX DIFF OF 3.0 & FAILED TO FURTHER PRESSURIZE. CABIN ALTITUDE HIGH ANNUNCIATOR ILLUMINATED, DEPLOYED OXYGEN MASKS, DECLARED AN EMERGENCY & RETURNED. Mar 27, 2015 · N201GL · Beech 1900DSDR MASA2015032712982A/C Pack · smokeAT GATE, COCKPIT & CABIN FILLED WITH SMOKE, LT PACK.Mar 27, 2015 · N248LR · Cndair CL6002D24SDR ASAA2015032411102Warning Light · false activationLEFT PACK LIGHT COMES ON AT RECALL, GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. NR 1 CONT. BITE SHOWED RAM AIR ACTUATOR FAULT, RESET FAULT. SECOND BITE, NO FAULTS, REF FIM 21-62-00-810-801. GROUND VERIFICATION SUCCESSFUL REF MM 21-61-00. NO HISTORY 30Mar 24, 2015 · N519AS · Boeing 737890SDR ASAA2015032411100Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED. PERFORMED QRH AND THE LIGHT EXTINGUISHED. ACFT GROUNDED. PERFORMED PACK/ZONE TEMPERATURE CONTROLLER BITE PROCEDURE, REF FIM 21-62 TASK 801 WITH NO FAULTS FOUND, WITH NO HISTORY 90 DAYS. REF FIM 21-62, TASK 831, SUSPECT INTERMIMar 24, 2015 · N403AS · Boeing 737990ERSDR ASAA2015032211063Controller · malfunctionedAFTER ENGINE START RECALL, LT PACK LIGHT ILLUMINATES. RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED TEMP CONTROLLER BITE REF FIM 21-62, TASK 801. LT TCV FAULT LOGGED BUT CURRENT STATUS SHOWS IT WORKING NORMALLY. RESET FAULT, FLT DECK TEMP CMar 22, 2015 · N413AS · Boeing 737990ERSDR ASAA2015032211061Valve · malfunctionedFWD SUPPLY DUCT INTERMITTENTLY, UNCONTROLLABLE TEMPERATURE VARIES FROM 16-60 DEGREE C. F/A REPORTED TEMP FLUCTUATIONS IN CABIN. ACFT GROUNDED. RAN PACKS FOR 45 MINUTES, WAS ABLE TO VERIFY FWD SUPPLY DUCT TEMP FLUCTUATES. BITE TEST BOTH CONTROLLERS NR 2 SHOMar 22, 2015 · N435AS · Boeing 737990ERSDR REXA2015032100340Acm · malfunctionedDURING DESCENT A PUFF OF SMOKE FOLLOWED BY WHAT APPEARED TO BE TINY METALLIC PIECES CAME OUT OF FIRST OFFICERS SIDE AIR GASPER. CLEAR BURNING SMELL, ALSO NOTED FOR ABOUT A MINUTE. ENGS WERE APPROX 60% N1. LT PAC PLACED ON DEFERRAL IAW MEL 21-51-01B CATEGORYMar 21, 2015 · N935XJ · Cndair CL6002D24SDR ASAA2015032011039Warning Light · false activationAFTER ENGINE START CHECKLIST RECALL, RT A/C PACK LIGHT ILLUMINATED & EXINGUISHED WHEN MASTER CAUTION RESET WAS PUSHED. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST IAW AMM 21-51-00. VERIFY TEST SHOWS NO FAULTS. NO HISTORY FOR PAST 90 DAYS.Mar 20, 2015 · N583AS · Boeing 737890SDR ASAA2015032011038Valve · malfunctionedAFTER START, ON MASTER CAUTION RECALL, AIR COND AND RT PACK WITH MASTER CAUTION ILLUMINATED ACCOMPLISHED AIR CONDITION. QRH RT PACK TEMP CONTROL INOP. ACFT GROUNDED. ACCOMPLISHED BITE OF NR 2 TEMP CONTROLLER REF AMM 21-61-00-700-806-002. TCV FAULT ILLUMINATEMar 20, 2015 · N531AS · Boeing 737890SDR ASOA20150320027Acm · seizedFLIGHT 6104 THE CREW REPORTED SMOKE IN THE CABIN AND FLIGHT DECK DURING CLIMBOUT IN ICING CONDITIONS. THE ACFT RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE ACFT AND R & R THE NR 1 ACM, OPS CHECKS WERE PERFORMED WITH NO DEMar 20, 2015 · N14198 · Emb EMB145XRSDR DALA2015032202272A/C Pack · odorRECEIVED A BURNING ODOR AND HAZE WHEN LEFT PACK MOVED FROM FULL HOT TO COLD IN AUTO OR MANUAL. R & R TIMER RELAY, FAN, GROUND BLOWER AND R2-4. OPS CHECKED GOOD.Mar 17, 2015 · N963DN · Doug MD9030SDR ASAA2015031710990Actuator · failedLEFT "PACK" LIGHT ILLUMINATES ON RECALL. ACFT GROUNDED. REPLACED RAM AIR INLET ACTUATOR REF AMM 21-51-21-400-80.Mar 17, 2015 · N569AS · Boeing 737490SDR ASAA2015031510968Valve · malfunctionedAT CRUISE FL 360, MASTER CAUTION ILLUMINATED W/ LT PACK LIGHT. RAN QRH AND LIGHT EXTINGUISHED WHEN MASTER CAUTION PUSHED. NO PACK OVERHEAT NOTED. ACFT GROUNDED. REPLACED LT PACK TEMP CONTROL VALVE. TEST, BITE TEST, LEAK CHECK ALL GOOD REF MM 21-51-10.Mar 15, 2015 · N408AS · Boeing 737990ERSDR ASAA2015031510966Valve · malfunctionedRIGHT PACK LIGHT ILLUMINATED DURING RECALL AND RESETS. ACFT GROUNDED. FOUND TEMPERATURE CONTROL VALVE FAILED BITE CHECK. REPLACED TEMPERATURE CONTROL VALVE ON RT PACK IAW MM 21-51-10.Mar 15, 2015 · N519AS · Boeing 737890SDR AALA20150314001Regulator Valve · faultyAIR INTERRUPT, RETURNED & EMER DECLARED. LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB FLIGHT CREW NOTED FUMES & ODOR IN COCKPIT. R & R LT & RT AIR CONDITIONING PRESS REGULATOR VLVS IAW AMM 21-31-01. R & R LT & RT COALESCER BAGS IAW AMM 21-20-02. Mar 14, 2015 · N9627R · Doug DC983SDR CA150316007Pulley · loose(CAN) ON ENGINE SHUTDOWN A CLICKING SOUND WAS HERD UNDER ENGINE COWLING. UPON INVESTIGATION IT WAS NOTICED THAT THE AIR CONDITIONER COMPRESSOR DRIVE PULLEY ALLEN SCREW HAD LOOSENED OFF AND THE DRIVE PULLEY WAS SLIPPING. DRIVE PULLEY, DRIVE PAD ASSY AND BELT WMar 13, 2015 · Airtrc AT402BSDR ASAA2015031310941Warning Light · false activationAFTER PUSH AND START RT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. ACCOMPLISHED GROUND VERIFICATION AND OPS TEST, TESTED 5 TIMES, OPS NORMAL ALL THE TIME REF MM 21-61-00-700-806-002.Mar 13, 2015 · N532AS · Boeing 737890SDR ASAA2015031310940Warning Light · false activationLEFT PACK LIGHT ILLUMINATES ON RECALL. ACFT GROUNDED. ACCOMPLISHED GROUND VERIFICATION AND OPS TEST. TESTED 5 TIMES, OPS CHECK NOMAL ALL THE TIME REF MM 21-61-00-700-806-002.Mar 13, 2015 · N532AS · Boeing 737890SDR ASAA2015031210939Controller · failedRIGHT PACK LIGHT ILLUMINATES ON MASTER CAUTION RECALL. LIGHT EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED NR 2 PACK ZONE TEMP CONTROLLER BITE REF AMM 21-62, TASK 801 AND VERIFIED SHOWING PACK ZONE CONTROLLER FAULT ON ALL SAVED LEGS. R & R Mar 12, 2015 · N413AS · Boeing 737990ERSDR ASOA20150311014Acm · odorCREW REPORTED NR 1 PACK NOT WORKING AND PRODUCING A STRONG ELECTRICAL SMELL DURING FLIGHT. ITEM WAS INTIALLY PLACED ON MEL. ON 3/15/15 MX R & R THE NR 1 ACM WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Mar 11, 2015 · N13908 · Emb EMB145LRSDR FDEA201503110811Actuator · failedLEFT PACK DEFERRED, THE RT PACK INLET TEMP CLIMBED TO 110 DEGREES C, WITH ASSOCIATED ECAM ADVISORY. FLOW INDICATOR WAS ALSO EXTREMELY UNSTABLE, OSCILLATING FROM STOP TO STOP. RETURNED TO DEPARTURE. R & R NR 1 & 2 PACK RAM TURBINE BYPASS VALVE ACTUATORS IAMar 11, 2015 · N662FE · Airbus A300F4605RSDR AALA20150312006Switch · faultyAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT WAS NOT OVERWEIGHT. DURING CLIMB OUT AT FL180, THE RT PACK ILLUMINATED & DID NOT EXTINGUISH AFTER RESET BUTTON PRESSED, ACFT RETURNED. REPLACED RT TURBINE INLET OVERHEAT SWITCH IAW AMM 21-52-41. REPLACEMar 11, 2015 · N808NN · Boeing 737823SDR AALA20150311019Switch · faultyAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT WAS NOT OVERWEIGHT. DURING CLIMB OUT AT FL180, THE RT PACK ILLUMINATED & DID NOT EXTINGUISH AFTER RESET BUTTON PRESSED, ACFT RETURNED. REPLACED RT TURBINE INLET OVERHEAT SWITCH IAW AMM 21-52-41. REPLACEMar 11, 2015 · N808NN · Boeing 737823SDR R61A201503090159Acm · failedAROUND 10000 FT CREW HEARD A BANG AND THEN SMELLED AND SAW SMOKE. CREW DECLARED AND EMERGENCY AND ELECTED TO RETURN TO DEPARTURE WHERE THEY LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND FOUND PACK 1 ACM LOCKED UP. MAINTENANCE PLACED PACK 1 ON MEL IAW AMMar 9, 2015 · N809MD · Emb ERJ170100SUSDR ASAA2015030710874Valve · false activationON RECALL-RIGHT PACK LIGHT ILLUMINATED. ACFT GROUNDED. ACCOMPLISHED NR 2 PACK / ZONE TEMP CONTROLLER BITE, THIS PACK TCV LIGHT ILLUMINATED, REF FIM 21-62, TASK 801. REPLACED RT PACK TEMP CONTROL VALVE, INSTALLATION TEST OK, NO LEAKS NOTED REF MM 21-51-10 ANMar 7, 2015 · N570AS · Boeing 737890SDR ASOA20150305024Acm · contaminatedTHE CREW REPORTED THAT PACK 1 AND PACK 2 SMELLED LIKE BURNING OIL WHEN ON, ENGINE BLEEDS IN FLIGHT. THE ACFT LANDED WITHOUT INCIDENT, WHERE MAINTENANCE INSPECTED THE ACFT AND FOUND EVIDENCE OF APU INGESTION OF ANTI-ICE FLUID, OPERATIONALLY TESTED BOTH PACKS UMar 5, 2015 · N21129 · Emb EMB145XRSDR ASAA2015030510873Bulb · failedWITH AIR TEMP SELECTOR SELECTED TO LT PACK, GAGE INDICATES OFF SCALE LOW. ACFT GROUNDED. VERIFIED DISCREPANCY. REPLACED LT PACK TEMP BULB, T488. REPAIR CONFIRMATION SATISFACTORY REF FIM 21-61/854.Mar 5, 2015 · N568AS · Boeing 737890SDR ASAA2015030510872Warning Light · false activationLEFT PACK LIGHT ON. ACFT GROUNDED. VERIFIED WITH FLT CREW THAT LIGHT EXTINGUISHED ON MASTER CAUTION RESET. PERFORMED BITE TEST OF BOTH CONTROLLERS IAW FIM TASK 21-61, TASK 801. NO FAULTS FOUND, GROUND VERIFICATION CK'S NORMAL. NO HISTORY PAST 30 DAYS.Mar 5, 2015 · N408AS · Boeing 737990ERSDR UHLA2015030500150Warning Light · false activationTHE CREW REPORTED THAT THEY RECEIVED A RAM AIR VALVE FAIL MESSAGE IN FLIGHT. THE CREW RETURNED TO FIELD AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE DEFERRED THE RAM AIR VALVE. THE DEFERRAL WAS CLEARED LATER THAT DAY WHEN THE RAM AIR VALVE SUCCESSFULLY Mar 5, 2015 · N273SK · Emb EMB145LRSDR SIMA20150303005Sleeve · blownWHILE RUNNING PROCEDURES FOR ITEM NR 1, RECEIVED PACK 2 OVLD, FOLLOWED BY BURNING SMELL. FOUND BLOWN SLEEVE FWD OF D C V CAUSING BURNING SMELL. R & R SLEEVE AMM 21-60-01. LEAK CHECK & OPERATIONS CHECKED GOOD AT THIS TIME.Mar 3, 2015 · N601DW · Emb EMB145LRSDR ASAA2015030310838Valve · malfunctionedON RECALL AFTER ENGINE STARTS, RT PACK LT ILLUMINATES. LIGHT EXTINGUISHES ON RESET. ACFT GROUNDED. FOUND RT TEMP CONTROL VALVE FAILED BITE TEST. REPLACED RT TEMP CONTROL VALVE IAW MM 21-51-10.Mar 3, 2015 · N461AS · Boeing 737990ERSDR SIMA20150303004Clamp · failedDURING CLIMB CREW RECEIVED PACK 1 OVLD MSG FOLLOWED BY PACK 1 OVLD MSG. CREW COMPLIED WITH AOM VOL 1 PROCEDURES, DECLARED AN EMER & RETURNED WITHOUT INCIDENT. FOUND BROKEN CLAMP AT PACK 1 VALVE. R & R CLAMP IAW AMM 21-51-01. LEAK & OPS CHECKED GOOD.Mar 3, 2015 · N601DW · Emb EMB145LRSDR SIMA20150301003Acm · seizedSMOKE IN CABIN, PERFORMED OPS CHECK OF LT PACKS IAW AMM 21-51-00. LT PACK CHECKED GOOD, CONFIRMED SMOKE TO BE FROM INOPERATIVE NR 2 PACK. . RT ACM APPEARS TO BE SEIZED & INOPERATIVE. REMOVED AND REPLACED RT ACM IAW AMM 21-51-08. OPS CHECKED GOOD.Mar 1, 2015 · N545PB · Cndair CL6002C10SDR UIEA2015030100156Valve · faultyBOTH PACKS RUNNING, UNABLE TO MAINTAIN CABIN TEMP BELOW OAT. DURING INSP FOUND RT PACK LOW LIMIT VLV FAULTY. R & R IAW AMM 21-51-11 201. OPERATIONS CHECKED OK.Mar 1, 2015 · N641GT · Boeing 76738ESDR DALA2015030201779Acm · contaminatedEXCESSIVE ODOR FROM PACKS ON TAKEOFF AND CLIMBOUT. SLOW TO DISSIPATE. NR 1 ENGINE - PULLED FAN HUB CAP AND FOUND OIL PUDDLE ALSO OIL WETTING IN 2.5 BLEED PORTS IAW AMM 72-30. PERFORMED SMOKE INSP IAW AMM 05-51-56. PERFORMED OIL CONT. REMOVAL OF AIR CONDITIFeb 27, 2015 · N698DL · Boeing 757232SDR ASAA2015022610794Actuator · failedRT PACK ILLUMS ON RECALL. EXTINGUISHES ON RESET. ACFT GROUNDED. WHILE ON DEFERRAL, RT RAM DOOR FULL OPEN LIGHT ILLUMINATED THROUGHOUT FLIGHT WITH ALTERNATE PACK CONTROLLER IN USE. RT TEMP CONTROLLER BITE CK FAULTS. REPLACED RT RAM AIR EXHAUST ACTUATOR IAW MFeb 26, 2015 · N461AS · Boeing 737990ERSDR CALA2015022700133A/C Pack · smokeBAD ODOR & SMOKE OCCURRED IN THE CABIN AFTER TAKEOFF. RETURNED TO FIELD. FOLLOWED TASK 05-51-26-800-801C1. ISOLATED SMELL TO RT PACK, NO TRACE OF OIL IN RT DUCTS. RAN ENGS AT 65% - 70% POWER. UNABLE TO REMOVE SMELL FROM RT PACK. 40 MIN ENG RUN & NO SMOKE Feb 26, 2015 · N37274 · Boeing 737824SDR ASMF201503018Acm · malfunctionedDURING TRANSIT CHECK, SMOKE WAS DETECTED IN CREW & PAX CABINS. PERFORMED FAULT ISOLATION PROCEDURE IAW DMC-B787-A-24-10-F5-G4A-421A-A, DETECTING THE MSG CABIN AIR CPRSR R1 STATUS & MSGS 21-41510 & 21-65211. SO THE ACM WAS REPLACED IAW DMC-B787-A-21-52-02-01AFeb 25, 2015 · N961AM · Boeing 7878SDR ASAA2015022510782Unknown · unknownRIGHT PACK LIGHT ILLUMINATED ON MASTER CAUTION RECALL DURING LANDING CHECKLIST. PACK LIGHT WENT OUT WITH MASTER CAUTION RESET. ACFT GROUNDED. RELEASED IAW MEL 21-32B. AFTER FLAP RETRACTION, RT SIDE RAM DOOR FULL OPEN BLUE LIGHT REMAINED ILLUMINATED. INTERROFeb 25, 2015 · N461AS · Boeing 737990ERSDR DXTA2015022505986Acm · unserviceableACRID SMELL NOTED DURING DESCENT. AT AUTOPILOT DISCONNECT, NO TONE AND BOTH PFDS SWITCHED UNCOMMANDED AFTER TOUCHDOWN TO SHORT RANGE CROSS SIDE INDICATION FROM FMS MODE. STARTED TROUBLE SHOOTING SYSTEM BY GAINING ACCESS TO MAINTENANCE PAGE AND CHECKING SYSTEMFeb 24, 2015 · N938QS · Cessna 750SDR ASAA2015022410759Actuator · failedLEFT PACK AMBER LIGHT ILLUMINATED ON APPROACH INTO SEATTLE. QRH RUN. LIGHT EXTINGUISHED. PACK LIGHT ILLUMINATED AGAIN ON LANDING. RESET ON TAXI IN. ACFT GROUNDED, BITE TEST OF LT PACK/ZONE TEMP CONTROLLER, M1442, FAULTS RAM AIR INLET ACTUATOR. REPLACED LFeb 24, 2015 · N530AS · Boeing 737890SDR ASAA2015022310749Actuator · failedLEFT RAM DOOR FULL OPEN LIGHT REMAINED ILLUMINATED. ACFT GROUNDED. WHILE APPLYING MEL FOUND LT AC BAY EXHAUST DUCT, TO LOUVERS, TORN. REPLACED FLEX DUCT IAW MM 21-51-24-400-801, STEP I 3, C&D, LEAK CHECKED GOOD. RAM AIR EXHAUST ACTUATOR INSTALL STEP 6 GROUNFeb 23, 2015 · N431AS · Boeing 737990ERSDR MASA2015022112913A/C Pack · failedSMOKE IN THE CABIN. RIGHT ACM FAIL.Feb 22, 2015 · N926LR · Cndair CL6002D24SDR ASAA2015022110711Valve · failedON PRESSING RECALL ON AFTER START CHECKLIST RT OVERHEAD AMBER LIGHT ILLUMINATED PACK LIGHT EXTINGUISHED PACK ON MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST REF MM TASK 21-61-00. FOUND RT PACK TCV VALVE INOPERATIVE. R Feb 21, 2015 · N533AS · Boeing 737890SDR SIMA20150221002Acm · seizedSMOKE IN THE CABIN & COCKPIT AT 24000. FLIGHT ATTENDANT NOTED A HAZY SMOKE FROM THE REAR CABIN. SMOKE FROM EL RELAY BOX BEHIND FIRST OFFICERS SEAT. SMOKE DISSIPATING ON DESCEND TRANSFERRED TO NRWC 613-RSW-02186. REF NRWC 613-RSW-02186 FOR DETAILS. FOUND LFeb 21, 2015 · N613AE · Emb EMB145LR
Back to JASC 2150