JASC 2150
Service difficulty reports · 12,393
Reports filed under 2150 · Cabin Cooling System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2014022106940Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED ON RECALL, RESET. ACFT GROUNDED. BITE OF RIGHT PACK/ZONE TEMP CONTROLLER IAW FIM 21-62, TASK 801 SHOWED RAM AIR ACTUATOR FAULT BUT VERIFY TEST DID NOT CONFIRM FAULT. ACCOMPLISHED T/C FOR RIGHT RAM AIR ACTUATOR FAULT IAW FIM 21-6SDR ASAA2014022106936Actuator · faultedLEFT PACK ANNUNCIATION ON MASTER CAUTION RECALL DURING DECENT. ANNUNCIATION EXTINGUISHED ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISH PACK - ZONE TEMP. CONTROLLER BITE TEST, NR 1 CONTROLLER SHOWS FAULT FOR LT RAM AIR ACTUATOR IAW MM 21-61-00-700-806-SDR ASAA2014021906914Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. PERFORMED RESET ON CPC NR 1 AND RAN PRESSURIZATION SYS GROUND TEST WITH NO FURTHER FAULTS NOTED IAW AMM 21-31-00-700-802.SDR ASAA2014021906913A/C Pack · warning lightRT PACK LIGHT ILLUMINATED. WOULD NOT RESET, PACK TUTRNED OFF. ACFT GROUNDED.SDR CALA2014022190415A/C Pack · faultedPACK 2 FAULT DISPLAYED ON UPPER ECAM SCREEN, AIR. RESTARTED ENGS AT THE GATE. PACK 2 OPERATED NORMAL, NO FAULTS.SDR ASAA2014021706880Warning Light · illuminatedRIGHT PACK LIGHT ILLUMINATED. QRH PROCEDURE COMPLIED WITH. PACK LIGHT EXTINGUISHED ON RESET. NO OPS RESTORED. ACFT GROUNDED. BITE CHECKED RT PACK-ZONE TEMP CONTROLLER, NO FAULTS NOTED NO HISTORY PAST 30 DAYS. OK FOR SERVICE.SDR ASAA2014021406849Warning Light · false activationAIR CONDITIONING, AUTO FAIL LIGHT CAME ON WHILE TAXING IN. ACFT GROUNDED. BITE CHECKED NR 1 AND NR 2 CPC FIM 21-31, TASK 827, 802 FOUND NR 2 CPC OFV LRU FAIL. OPS CHECKED NR 2 CPC IAW AMM 2131-00-710-801 AND AMM 21-31-00-700-802, ALL GROUND FUNCTIONAL TESTS SDR ASAA2014021306850Actuator · failedDURING LANDING, RT PACK LIGHT ILLUMINATED ON RECALL. NO OTHER DEFECTS NOTED. ACFT GROUNDED. BITE CKD RT PACK ZONE TEMP REF AMM 21-61-00. FOUND FAULT ON RT PACK RAM AIR ACTUATOR. R & R RT PACK RAM AIR ACTUATOR, REF AMM 21-51-21-000-801 AND AMM 21-51-21-400-SDR SIMA20140213002Acm · failedBLACK SMOKE COMING OUT OF GLARE SHIELD JUST ABOVE EYEBALL VENT. R & R LT ACM. OPERATIONS CHECKED GOOD AT THIS TIME IAW AMM 21-51-03.SDR ASAA2014021006818A/C Pack · unknownF/A REPORTS ROWS 13-14, EXTREMELY WARM. TO GET TEMP COMFORTABLE IN ROWS 13-14 THE REST OF THE PLANE WAS COLD. ACFT GROUNDED. OPERATED AIR-CONDITIONING PACKS LT AND RT USING APU AIR. CONFIGURED TEMP CONTROL TO VARIOUS TEMP SETTINGS FOR EACH ZONE. USING AN ISDR ASAA2014021006817Warning Light · false activationAFTER START RECALL, AIR COND AND CONT CAB ZONE TEMP LIGHT ILLUMINATED. LIGHT EXTINGUISH WITH M/C RESET. ACFT GROUNDED. RAN LT & RT PACKS FOR 10 MINS, BITE TEST OF NR 2 TEMP CONTROLLER REF 21-61, TASK 801. NO FAULTS FOUND, NO 30 DAY HISTORY. CLEANED COCKPITSDR MASA2014021030921A/C Pack · overtempPACK OVER TEMP CAUSE SMOKE IN AFT LAVATORY.SDR SWIA201436339Acm · failedSMOKE IN CABIN & RIGHT PACK OVER-TEMP IN MANUAL & AUTO. FLT4597 REPLACED RT ACM PN ON OFF: GG670-95009-5, SN ON 00749 & SN OFF 01472.SDR ASAA2014020906808Control Valve · malfunctionedDURING CLIMB OUT, RT PACK LIGHT ILLUMINATED. QRH PROCEDURE RAN. LIGHT REMAINED. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROL BITE. FOUND RT PACK TCV FAULT. REPLACED RT PACK TCV REF: FIM TASK 21-62 TASK 831, MM 21-51-10. OPS CKD GOOD NO FAULTS, REF: MSDR CA140210002Acm · seized(CAN) CREW REPORTED SMOKE IN THE CABIN WHICH RESULTED IN AN EMERGENCY EVACUATION ON THE TAXIWAY. PASSENGER AND CREW ARE REPORTED TO BE OK. MAINT FOUND LT ACM HAS LOCKED UP SO MOST LIKELY A BEARING LOSS OF FUNCTION. ACM REPLACED.SDR ASAA2014020806802Warning Message · illuminatedLEFT PACK ILLUMINATED ON MASTER RECALL, EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED.SDR ASAA2014020806800Actuator · failedDURING MASTER CAUTION RECALL, LT PACK ANNUNCIATOR ILLUMINATED. PACK ANNUNCIATOR EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. ON AUTO TEMP CONTROLLER BITE TEST LEFT RAM DOOR ACTUATOR FAULT LOGGED. AFTER RESET FAULT, FAULT CAME BACK AGAIN. IAW FIMSDR CALA2014021000171Acm · seizedAFTER TAKEOFF FS ADVISED OF A MISTY FOG IN AFT CABIN WHICH DISAPPEARED RELATIVELY QUICKLY. DID AIR RETURN TO BOS REF LOG 47978572. INSPECTION RT ACM WAS FOUND SEIZED. CORRECTION ON LOG 7550766.SDR YENA20140207030Filter · odorFOUL ODOR, NO BURNING IN CABIN DURING INITIAL DESCENT . ACCOMPLISHED TSM TASK 05-50-00-810, ISOLATED NR 1 PACK CONTAMINATED. R & R NR 1 PACK OZONE FILTER IAW AMM 21-51-41, OPS CHECKED OK.SDR ASAA2014020706789Warning Light · false activationON RECALL, LT PACK ANNUNICATOR ILLUMINATES. EXTINGUISHES WHEN MASTER CAUTION RESET. ACFT GROUNDED. RESET NR 1 PACK TEMP CONTROLLER REF AMM 21-61-00. PERFORMED OPS TEST AT LT PACK REF AMM 21-61-00, OPS CHECK NORMAL, NO FAULTS NOTED.SDR ASAA2014020706788Control Valve · malfunctionedRT PACK LIGHT ILLUMINATES ON RECALL. THE ASSOCIATED LIGHT EXTINGUISHES ON MASTER CAUTION. ACFT GROUNDED. PERFORMED BITE CHECK, FOUND RT TCV INOPERATIVE. R & R TCV REF AMM 21-51-10. PERFORMED OPS/LEAK CHECK, OPS/LEAK CHECK GOOD. PERFORMED BITE CHECK, BITE CSDR DALA14007810951Acm · odorDURING CLIMB, CREW BEGAN DETECTING FUMES. THE ODOR INCREASED AT CRUISE FLIGHT AND WAS WORSE IN THE REAR CABIN AREA. FLIGHT WAS DIVERTED, WHEN THE FUMES INFILTRATED COCKPIT TO SUCH A DEGREE THAT THE FLIGHT CREW DONNED MASKS. MAINTENANCE REPLACED THE LT AIR CYSDR ASAA2014020606791Control Valve · malfunctionedDURING TAXI, RIGHT PACK LIGHT ILLUMINATED ON RECALL, WILL NOT RESET. ACFT GROUNDED. BITE TEST OF RT PACK ZONE TEMP CONTROLLER FAULTS RT TCV. REF FIM 21-62, TASK 831. REPLACED RT PACK TEMP CONTROL VALVE REF AMM 21-51-10. NO LEAKS NOTED. PERFORMED PACK ZONESDR ASAA2014020606790Control Valve · warning lightDURING PUSH BACK, ON RECALL LT PACK LIGHT ILLUMINATED, EXTINGUISHED ON MASTER CAUTION RESET. ACFT GROUNDED. BITE CHECK FAULTED TCV ON LT PACK. R & R TCV IAW AMM 21-51-10. OPS CHECKED GOOD, NO LEAKS NOTED.SDR UIEA2014020600045Control Valve · faultyLEFT PACK INOPERATIVE. R & R LT PACK CONTROL VLV IAW AMM 21-51-01 401. OPERATIONS CHECKED OK. PN OFF 396462, SN OFF 7100.SDR UIEA2014020600044Unknown · malfunctionedLEFT PACK INOPERATIVE LIGHT ON IN AUTO. PERFORMED BITE TEST ON PACK CONTROLLER PE AMM 21-25-00 NO FAULTS. MANUALLY CYCLED PACK CONTROL VLV OPERATIONS CHECKED NORMAL.SDR CA140214003Brushes · worn(CAN) VAPOR CYCLE COMPRESSOR BRUSHES OVER WORN CAUSING THE MOTOR TO OVERHEAT WHICH IN TURN MELTED THE PLASTIC COVER, THIS CAUSED THE COOLING FAN BLADES TO CONTACT THE COVER AND BEND/TEAR. THE BRUSHES HAD 270.7 TT, INSPECTION CRITERIA IS TO INSPECT EVERY 300 HSDR ASAA2014020306760Control Valve · malfunctionedRIGHT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. GROUND TEST CONFIRMED RT TEMP CONTROL BITE, FAILED THIS PACK TCV IAW FIM 21-62/801. RESET TEMP CONTROLLER. R & R TEMPERATURE CONTROL VALVE RT IAW AMM 21-51-10. OPS CHECKED GOOD.SDR ASAA2014020206755Control Valve · faultedAFTER ENGINE START, ON RECALL, RT PACK LIGHT ILLUMINATED. QRH PROCEDURE FOLLOWED. PACK LIGHT EXTINGUISHED ON MASTER CAUTION RESET. ACFT GROUNDED. PACK-ZONE TEMP CONTROLLER BITE CHECKED IAW FIM 21-62, TASK 801, SHOWED RT PACK TEMP CONTROL VALVE FAULT AND VERSDR ASAA2014020106728Warning Light · false indicationRT PACK LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. PERFORMED FIM BITE OF PACK-ZONE TEMP CONTROLLER 21-62, TASK 801. NO FAULTS, RAN PACKS 20 MINUTES THRU FULL TEMP COMMANDS, RAN FIM TASK 21-62, TASK 801, NO FAULTS AND NO RECENT HISTORY.SDR ASAA2014020106725Warning Light · intermittentLEFT RAM DOOR FULL OPEN LIGHT REMAINED ILLUMINATED DURING CLIMB AND CRUISE. ACFT GROUNDED. BITE TEST OF TEMP CONTROLLERS, FOUND OK. NO FAULTS. ACCOMPLISHED GROUND VERIFICATION IAW FIM 21-51, TASK 803. FOUND TO BE INTERMITTENT FAULT.SDR ASAA2014013106723Control Valve · faultedRIGHT PACK LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. RESET OK, LIGHT EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED BITE OF RT PACK-ZONE TEMPERATURE CONTROLLER IAW FIM 21-62, TSK 801. CONTROLLER FAULTED THE TCV. R & R THE TCV REF MMSDR ASOA20140131016Acm · inoperativeDURING FLIGHT, CREW REPORTED SMOKE IN COCKPIT. ACFT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND R & R THE NR 2 ACM, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASAA2014013006726Warning Light · false activationLEFT PACK LIGHT ILLUMINATED DURING RECAL, EXTINGUSHIES ON RESET. ACFT GROUNDED. LEFT PRIMARY TEMP CONTROL INOPERATIVE, BITE CHECK PERFORMED. LEFT TCV, VERIFY PASS & RESET. NO HISTORY 90 DAYS. OPS GOOD IAW MM 21-61-00-700-806.SDR HALA2014013000020A/C Pack · overheatedNR 1 A/C PACK OVERHEATED, STAYED AT 100 DEGREES. ECAM MESSAGE APPEARED DURING TAXI, RETURNED TO GATE. FOLLOWED TSM 21-52-00-810-820-A, SYS RESET AND PERFORMED SYSTEM TEST OF TEMP CONTROL SYS ON MCDU (ATA21) AND THEN TEST OK. OK FOR SERVICE IAW TSM 21-52-00-SDR ASAA2014012812508Warning Light · false activationDURING CRUISE, RT SIDE RAM DOOR FULL OPEN LIGHT ILLUMINATED. ACFT GROUNDED. NO FAULTS LOGGED ON ZONE CONTROLLER, BITE TEST PASS, SYS OPS CHECKED NORMAL IAW FIM TASK 21-51, 803, GROUND CONFIRMATION SUCCESSFUL.SDR HALA2014012600013Sensor · malfunctionedLEFT PACK TEMP, LT PACK OFF ILLUMINATED, COOLED FIVE MINUTES THEN RESET. LEFT PACK TEMP, TEMP OFF ILLUMINATED AGAIN. R & R LT PACK COMPRESSOR OUTLET SENSOR IAW AMM 21-51-06. OPS CHECKED GOOD, OK FOR SERVICE.SDR DALA14005399007Acm · leakingTHE CREW REPORTED A HOT ODOR AND VISIBLE HAZE IN THE CABIN ENROUTE. NO EMERGENCY DECLARED AND THE HAZE AND ODOR DISSIPATED AFTER THE RT PACK WAS TURNED OFF. MAINTENANCE PERFORMED CABIN SMOKE-ODOR TROUBLESHOOTING AND FOUND THE RT ACM LEAKING. MAINTENANCE RSDR VNAA2014012500016Acm · odorCREW REPORTED SMOKE TOILET MESSAGE IN FLIGHT. MESSAGE CLEARED BEFORE RUNNING QRH. CREW RETURNED TO FIELD. MAINTENANCE INSPECTED, R & R LT AND RT ACM, WATER SEPARATOR COALESCER SOCKS AND PERFORMED CHECKS. ACFT RELEASED FOR SERVICE. WORK ACCOMPLISHED IAW AMMSDR HALA2014012300011Actuator · faultedNR 2 AIR PACK REGULATOR FAULT, NR 2 PACK RAM DOOR CLOSED. DEACTIVATED RAM AIR INLET ACTUATOR AND CIRCUIT BREAKER PULLED. RAM AIR INLET ACTUATOR CONNECTOR DISCONNECTED AND TIED, DOOR FULLY OPENED. R & R NR 2 PACK AIR INLET FLAP ACTUATOR IAW AMM 21-53-51-00SDR ASAA2014012312468Warning Message · false activationLEFT PACK LIGHT COMES ON AT RECALL, OUT WITH RESET MASTER CAUTION. ACFT GROUNDED. ACCOMPLISHED PACK-ZONE TEMP CONTROLLER BITE AMM 21-61-02. OPS CHECKED NORMAL, GROUNDED, VERIFICATION SUCCESSFUL.SDR ASAA2014012012425Actuator · failedFLIGHT CREW REPORTED RT RAM AIR INLET DEFLECTOR DOOR NOT DEPLOYED. ACFT GROUNDED. CONFIRMED ACTUATOR IS INOPERATIVE. REPLACED ACTUATOR IAW TASK 21-51-21-400-801. OP CHECKS GOOD. TEMP CONTROLLER BITE TEST PASSES.SDR ASAA2014011912407A/C Pack · faultedDURING LANDING, MASTER CAUTION LIGHT ILLUMINATED FOR A RT PACK, EXTINGUISHED WITH RESET. ACFT GROUNDED. IAW FIM 21-62, TASK 801, SHOWS INTERMITTENT RT RAM ACTUATOR FAULT. VERIFICATION TEST OK. FAULT RESET, RT PACK LIGHT REMAINS EXTINGUISHED ON RECALL.SDR UIEA2014011800014Control Valve · defectiveRIGHT PACK TEMP CONTROL INOPERATIVE AUTO, STBY OK. R & R RT PACK TEMP CONTROL VLV IAW AMM 21-51-12. OPERATIONS & LEAK CHECKED GOOD.SDR ASAA2014011712405Control Valve · failedRIGHT PACK LIGHT ILLUMINATES ON RECALL, EXTINGUISHES ON RESET. ACFT GROUNDED. R & R RT TEMP CONTROL VALVE IAW AMM 21-51-10. OPS CHECKED GOOD.SDR CALA2014011690170A/C Pack · malfunctionedPACK 2 EICAS ADVISORY MESSAGE DISPLAYED. NEITHER PTC IN CONTROL OF PACK 2 FOR 30 SECONDS OR PACK COMPONENT FAILURE OR OVERHEAT OR PACK TRIP DUE TO OVERHEAT OR OUT OF SEQUENCE. HAD SYS FAULT LIGHT WITH PACK 2 EICAS MESSAGE. PACK 2 RESET OK IAW QRH PROCEDURE.SDR CA140115006Acm · leaking(CAN) ACFT WAS ACCELERATING FOR TAKEOFF WHEN THE CREW REJECTED TAKEOFF AT LOW SPEED, ABOUT 10 SECONDS AFTER APPLYING TAKEOFF THRUST, AFTER THE CAPTAIN SMELLED SMOKE IN THE COCKPIT. THE ACFT STOPPED ON THE RUNWAY, FLIGHT AND CABIN CREW ESTABLISHED THERE WAS SMSDR UIEA2014011400010Controller · malfunctionedLEFT PACK INOPERATIVE LIGHT ON IN AUTO POSITION. R & R LT PACK TEMP CONTROLLER IAW AMM 21-51-14, OPERATIONS OK.SDR ASAA2014011212378Actuator · warning messageON APPROACH, RT PACK LIGHT ILLUMINATED. LIGHT EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. REPLACED RT RAM AIR DOOR ACTUATOR, REF MM 21-51-21. OPS CK GOOD.SDR ASAA2014011212377Warning Message · false activationRT A/C PACK LIGHT ILLUMINATES ON RECALL THEN EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. IAW FIM 21-62, TASK 803, INITIAL BITE SHOWS RAM ACTUATOR FAULT, VERIFICATION TESTED NORMAL. FAULT EXTINGUISHED. HAS NO OTHER RECENT HISTORY.
Back to JASC 2150