JASC 2160
Service difficulty reports · 3,040
Reports filed under 2160 · Cabin Temperature Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2024082608424Sensor · dirtyTRIM AIR VALVE FAIL CAUTION ON ENGINE START. COCKPIT TRIM DUCT TEMP RAN UP TO 230 DEGREES F BEFORE FAIL AND FLIGHT CREW NOTED A BURNING SMELL. CAUTION WENT OUT W/ QRH PROCEDURE. STARTED ODI SMOKE AND FUMES WORK CARD 0550-2001. NO ODORS FOUND. PER MCC REQUIRES SDR QMLA2024081620101Control Valve · failedALL OF CREW NOTED A MELTING OR BURNING PLASTIC SMELL. WE WERE ABOUT TO BEGIN OUR DESCENT FOR BASE, AND WERE ONLY ABOUT 15 MINUTES OUT, WITH MULTIPLE ALTERNATIVE AIRPORTS BELOW/NEAR US IF THE SMELL GOT WORSE AND I BECAME MORE CONCERNED ABOUT AN IMMINENT CHANCE SDR AALA202408141621Ecs · malfunctionedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: IMMEDIATELY AFTER TAKEOFF THE CONTROL CABIN TEMPERATURE BECAME EXCESSIVELY HOT AND THE CONTROL CABIN ZONE TEMP OVERHEAD LIGHT ILLUMINATED; AIRCRAFT AIR INTERRUPTED BACK TO AND LANDED SAFELY AT DFW.**SUPPSDR AALA202408123351Shutoff Valve · inoperativeAIRCRAFT WAS NOT GROUNDED: 21-20A MCDR SHUTOFF VALVE - NO FLOW LIGHT ILLUMINATED "SUPPLY AIRFLOW OFF" RESET NO HELP. MID FLT ATTENDANT CREW REST. DECESION WAS MADE TO DIVERT TO LAX. **SUPPLEMENTAL REPORT FOR SDR AALA202408093351.** (CLOSED) MAINTENANCE REPLACESDR UIEA2024072500749Valve · failedFWD TRIM VALVE FAIL.(<P>FWD TRIM VALVE WAS REPLACED IAW AMM 21-61-07-404-011-003 REV. 142 DATE 22 APR 24. TORQUE APPLIED 45 LB-IN S/N 0823900243 DATE 15 NOV 24. BONDING TEST WAS SATISFACTORY 2.2 MILLIOMHMS S/N DC- 005040 DATE 12 DEC 24. OPERATIONAL TEST WAS SASDR HALA20240729200Sensor · faultedETOPS - COCKPIT TEMP CANT HOLD A TEM. IT FLUCTUATES BETWEEN 50-100 DEGREES ALL FLIGHT. REMOVED AND REPLACED COCKPIT TEMP SENSOR 650HK REF AMM 21-63-17. OPS CHECK GOOD.SDR DALA2024070906938Sensor · faultedSHIP 3234 - ATO - AT APPROXIMATELY 20KTS DUE TO AIR PACK 2 OVHT ECAM MESSAGE. CORRECTIVE ACTION: PACK #2 PLACED ON MEL DEFERRAL. OK TO CONTINUE. (LP: 0436105) SUPPLEMENTAL INFO: FAULTS COMP TEMP SENSOR 32HH. R/R'D SENSOR 32HH PER A320 AMM 21- 61. RIGHT PACK WOSDR DALA2024070506796Regulator Valve · inoperative(LOG 5885652) ON TAXI-OUT, AFT FAS OBSERVED A ROTTEN EGG ODOR IN THE BACK OF THE CABIN AND GALLEY. RETURNED TO GATE. RAN ENGS WITH ONSIDE PACK SEPERATELY REF B737 AMM 71-00 AND WITH APU INDIVIDUALLY NO ODOR NOTED THROUGHOUT CABIN. NOTICED TRIM AIR VALVE HAVE ASDR CALA2024070900178Anti-Ice Valve · faultedREPLACED LT PACK ANTI-ICE VALVE IAW AMM 21-61-41 PB.401, DUE TO PACK OUTPUT TEMP INDICATION ALWAYS SHOWING BELOW FREEZING. REMOVED AND REPLACED LH PAC ANTI-ICE VALVE REF AMM 21-61-41-400-001-A. PURGED THE REMOVED SENSE LINES, ACCOMPLISHED PACK OPS TEST IAW SDR CALA2024062100052Controller · inoperativeAIRCRAFT IS HOT. CANNOT BE COOLED ON GND OR AIR UNTIL REACHING CRUISE. BITE TEST CABIN TEMP CONTROL, CTC HAS NO POWER TO BIT TEST, REST SYS, NO HELP. R & R CABIN TEMP CONTROLLER PER AMM 21-61-01 OPS CHKD GOOD. PERFORMED TEST, BOTH PACKS & SELECTING CABIN TEMSDR DALA2024061706157Controller · faultedSHIP 5812 -DIV/DE- UNABLE TO CONTROL AND WARM CABIN TEMPERATURE. CORRECTIVE ACTION: RESET LT/RT AUTO TEMP CONTROLLER C/BS AND LT/RT STANDBY CONTROLLER C/BS. SYSTEM TESTS GOOD.SDR NACA2024060900001Modulating Valve · stuckFLIGHT DECK TRIM MODULATING VALVE STUCK IN CLOSED POSITION. REMOVED AND REPLACED FLIGHT DECK TRIM AIR MODULATING VALVE PER AMM 21-61-07 OPS CHECK GOOD.SDR NACA2024060800003Regulator · failedAIR CONDITIONING IS ALMOST UNCONTROLLABLE ON BOTH PACKS IN AUTO AND MANUAL MODE. WHEN ON APU AIR, IT COVERS THE WHOLE COCKPIT WITH A LOT OF CONDENSATION. REMOVED AND REPLACED TRIM AIR PRESSURE REGULATOR AND SHUTOFF VALVE. PART INFORMATION MISSING.SDR NACA2024052900001Modulating Valve · failedMAIN DECK CARGO WOULD NOT COOL ADEQUATELY IN FLIGHT, FLIGHT DECK WOULD NOT HEAT, FLIGHT DECK AIR INDICATED FULL WARM. REMOVED AND REPLACED TRIM MODULATING VALVE IAW AMM 21-61-07 OPS CHECK NORMAL. NO TRAX INFORMATION, UNIT HAS ALREADY BEEN EXCHANGED OUT.SDR 2024FA0000390Sensor · faultyA BURNING RUBBER ODOR FILLED CABIN WITH THE ENVIRONMENTAL CONTROL SYSTEM IN THE AUTO MODE DURING CLIMB AFTER TAKEOFF.SDR YENA2024052800786Sensor · failedFLT#1408, CDG-JFK. (ETOPS) 'AIR PACK 2 REGULATOR FAULT; REMOVED AND REPLACED P2 COMP TEMP SENSOR (32HH) IAW AMM 21-61-11.OPS CHECK OK.'SDR YENA2024052800783Valve · faultedFLT#2288, JFK-AMS. (ETOPS) 'ON TAXI OUT COND TRIM AIR SYS FAULT COCKPIT TRIM AIR VALVE ( HOT AIR PRESS REGUL VLV - N703 AND UP, OPEN POSITION; REMOVED AND REPLACED TRIM AIR VALVE 11HK IAW AMM 21-63-51.OPS CHECK GOOD. THIS CLEARS MDDR MX-4 UPDATED. PLACARD REMSDR AALA202405242685Modulating Valve · inoperativeAIRCRAFT WAS GROUNDED: AFT CABIN TEMP CONTROLLER WILL NOT CONTROL CABIN TEMPERATURE IN AUTO. TEMPERATURE GOES FULL HOT WITH A SMELL OF BURNING PLASTIC IN FLIGHT DECK AND CABIN. REMOVED AND REPLACED AFT CABIN ZONE TRIM AIR MODULATING VALVE (AALA202405232685), SDR AALA202405247575Sensor · inoperativeAIRCRAFT WAS GROUNDED: AFT CABIN TEMP CONTROLLER WILL NOT CONTROL CABIN TEMPERATURE IN AUTO. TEMPERATURE GOES FULL HOT WITH A SMELL OF BURNING PLASTIC IN FLIGHT DECK AND CABIN. REMOVED AND REPLACED AFT CABIN ZONE TRIM AIR MODULATING VALVE ((AALA202405232685))SDR AALA202405232685Controller · malfunctionedAIRCRAFT WAS GROUNDED: AFT CABIN TEMP CONTROLLER WILL NOT CONTROL CABIN TEMPERATURE IN AUTO. TEMPERATURE GOES FULL HOT WITH A SMELL OF BURNING PLASTIC IN FLIGHT DECK AND CABIN. **SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).SDR AALA202405242924Valve · inoperativeAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS NOT DECLARED DUE TO: ZONE E TEMPERATURE INCREASED AIR CONDITION RESET FAILED ADDITIONALLY MULTIPLE SMOKE ALARMS SOUNDED AND SMELLED SMOKED IN FIRST CLASS CABINS; AIRCRAFT AIR INTERRUPTED BACK TO AND LANDED SAFELY AT BOS.SDR CALA2024052001504Sensor · faultedCOCKPIT AND CABIN UNCONTROLABLE 100DEG TO 16 DEG LOCKED FOR POSITIVE FIX TOOK RESISTANCE VALUES FOR TS198, TS200 AND TS01, ALL VALUES T/S IAW 757 FIM 21-51 FT 803 COMPLETED UPTO AND INCLUDING BLOCK COMPARABLE TO RIGHT SENSORS. SINCE LEFT PACK CONTROLLER STILL SDR SCNA2024052000242Controller · failedUNABLE TO CONTROL FLIGHT DECK TEMP. EXESSIVE HEAT. FOLLOWED QRH PROCEDURE TURNED OFF TRIM AIR SWITCH STILL UNCONTROLLABLE THEN TURNED OFF L- PACK PER QRH A/C TEMP WENT FULL COLD AND UNABLE TO CONTROL. HAD TO DESCEND TO WORK UP. REMOVED AND REPLACED ZONE TEMPESDR DXTA2024051311737A/C Pack · faultedAIR CONDITIONING CABIN TEMP GOES TO FULL HOT WHEN IN NORM & STBY MODES AND IS NOT CONTROLLABLE FROM THE GALLEY CONTROL PANEL. ACRID SMOKE ODOR LIKE BURNING ELECT INSULATION BY CREW.SDR HALA20240311063Selector · failedETOPS-FORWARD TRIM AIR VALVE NOT RESPONDING APPROPIATELY TO SWITCH POSITION. TEMP IN CABIN HOT WITH FULL COLD SET. PREVIOUSLY WRITTEN UP, NO CHANGE. REMOVED AND REPLACED TEMPERATURE SELECTOR PER AMM 21-63-11-000-001-A (21315 3/8/24. PENDING OPS CHECK. PERFORMESDR UIEA2024062700571Modulating Valve · faultedDIVERSION: FLIGHT DECK AND UPPER DECK AREA TEMPERATURE UNCONTROLLABLE.(<P>R/R FLT DECK ZONE TRIM MOD VLV AND ZONE TEMP CONTROL MOD PER AMM 21-61-10/401 AND 21-61-01/401. OPS CHK GOOD. </P>)SDR ABXA20240216324Warning Message · illuminatedDURING TAXI FWD CABIN TEMP EICAS MSG FWD CABIN LIGHT INOP ILUMINATED AC RETURNED TO GATE AND GROUNDED BY MAINTENANCE. MAINTENANCE DEFERRED FWD CABIN TEMP IAW MEL ABX-21-61-1-2.RETURNED TO SERVICE AND AC DEPARTED .SDR YENA2024020500226Controller · failedFLT#2223, (ETOPS). 'OUTBD CREW REPORTS CLASS II MX TEMP CTL 1 MSG ( CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY 4) FAULT(S) INDICATED BY TEMP CTL 1 (2) ). REMOVED AND REPLACED AIR CONDITIONING SYSTEM CONTROLLER #1 (ACSSDR ABXA2024012717Sensor · malfunctionedL PACK TEMP SHOWS INOP DURING TAXI AC RETURENED TO GATE AND MAINTENANCE GROUNDED AC .AND DEFERRED PACK FOR DEPARTURE IAW MEL ABX-21-51-3-1 AND RETURNED AC TO SERVICE.AC DEPARTED T/S SYSTEM FOUND BAD COMPRESSER OUTLET TEMP SENSOR FOR LH PACK R/R TEMP SENSOR WISDR CALA2024012300205Controller · faultedCONT CAB TEMP 40-65C IN CLIMB. T/S AND FOUND LT PACK TEMP SENSOR CONNECTOR LOOSE AND FAULTY, CAUSING PACK TCV TO PARTIALLY OPEN. REQ'S LT PACK TEMP SENSOR AND CONNECTOR REPLACEMENT. REPLACED TEMP SENSOR (T472) PER AMM 21-51-52/401. REQUIRES LEAK AND OPS CHECK.SDR ABXA2024012300115Sensor · faultedAFT CABIN TEMP EICAS MSG DURING TAXI .AC BTB MAINTENCE ENTERED AC AND DEFERRED SYSTEM IAW ABX MEL 21-61-1-2. RETURNED AC TO SERVICE AND AC DEPARTED. AC WAS REPAIRED IN PHX REPLACED MAIN CARGO AFT CABIN ZONE TEMP SENSOR IAW AMM 21-61-08. OPS CHECK TESTS GOOSDR ABXA20240116410Modulating Valve · malfunctioned"AFT CABIN TEMP EICAS MESSAGE CAME ON AT ENGINE START #2 DURING TAXI OUT AC RETURNED TO SERVICE AND MAINTENANCE GROUNDED AC.AND DEFERRED THE AFT CABIN TEMP MESSAGE IAW ABX MEL-21-61-1-2. AND RETURNED AC TO SERVICE FOR DEPARTURE .AFTER TROUBLE SHOOTING AT NEXTSDR ABXA20240108603Modulating Valve · malfunctionedDURING TAXI FWD CABIN TEMP EICAS PLUS FWD CABIN INOP LIGHT ,A/C RETURNED TO GATE AND MAINTENANCE GROUNDED A/C.DEFERRED SYSTEM FOR DEPARTURE IAW MEL ABX-21-61-1-2 TROUBLE SHOT AT NEXT BASE AND REMOVED AND REPLACED FWD CABIN TRIM AIR MODULATING VALVE IAW B AMM2SDR YENA2023122801656Control Valve · failedFLT#33, BOS-SFO. (ETOPS) 'CLASS TEMP CTL 2 MSG ( CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY 4) FAULT(S) INDICATED BY TEMP CTL 1 (2) ); REMOVED AND REPLACED # 2 FLOW CONTROL-VALVE ASSY IAW AMM 21-51-51-000-001-A. OPS CHECSDR HALA20231208265Unknown · unknownATB - ZONES 3,4,&5 UNCONTROLLABLE, SET AT MIN. TEMP WERE AT 80* AT LOWEST. FOUND PACK 1 AND 2 WATER EXCHANGER LINES DISCONNEDTED-CLAMPS MISSING. REPLACES BOTH LINES. CLEANED CABIN TEMP SENSORS. OPS CHECK TEMP CTRL AMM 21-63-00 -- ALL TEST PASS -- NO DEFECTSSDR DALA2023120509961Unknown · unknownSHIP 3037 -ATO- AT THROTTLE UP DUE TO COND HOT AIR FAULT. TRIM AIR PRSOV WAS ALREADY ON MEL. CORRECTIVE ACTION: RETURNED TO GATE FOR VALVE LOCK-OUT. REMAINED ON MEL. THEN R/R CONTROLLER AND TAPRV. OK FOR SERVICE. (5560916)SDR DALA2023120409928Unknown · unknownSHIP 3037 REJECTED TAKEOFF DUE TO "COND TRIM AIR SYSTEM FAULT" UPON INITIAL APPLICATION OF TAKEOFF POWER. CORRECTIVE ACTION: MOVED TO MEL. CONTINUE IN SERVICE. (5560916)SDR I5PA2023112975704Valve · faultyFLT NO.: N/A (MX FINDING). ESI - FLIGHT DECK TEMP CONTROL INOP. REPLACED LH PACK LOW LIMIT VALVE.SDR YENA2023112401455Unknown · unknownFLT#44, LGW-JFK. (ETOPS) 'COCKPIT AIR TEMPERATURE VERY DIFFICULT TO CONTROL CONSTANT VARIATION OF AIR TEMP BETWEEN 48F AND 108F (FROM DUCT); FOUND COCKPIT AIR TEMPERATURE SENSOR COVERED. REMOVED OBSTRUCTION FROM TEMP SENSOR A/C OK TO CONT FOR SVC.'SDR ASAA2023111246157Unknown · unknownZONE TEMP DID NOT RESET ON MASTER CAUTION SEVERAL TIMES DURING FLT. TEMP VLIMBED UNLESS CONTROL CABIN SET AF FULL COLD STAYED AT <20DEG MOST OF FLIGHT. GROUNDED - YES. VERIFIED FAULT, REF. L/P #60756322. ACCOMP. PACK ZONE BITE TEST, BOTH CONT. PASS VERIFIY TESSDR DALA2023111409371Unknown · unknownSHIP 3936 -ATB/FUMES- RETURNED TO ATL DUE TO BURNING ODOR IN COCKPIT AFTER TAKEOFF. CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. CORRECTIVE ACTION: #2 ZONE TEMP CONTROLLER FAULTS COCKPIT TRIM AIR VALVE. REPLACED SAME AND RECIRCULATION FILTERS. OPS CHECKS GOOD.SDR ASAA2023111246106Unknown · unknownCONT CABIN LIGHT ZONE TEMP ON RECALL, RESETS WITH MASTER CAUTION RESET. GROUNDED - YES. VERIFIED FAULT, ACCOMP PACK /ZONE TEMP CONT. BITE CONT #2 SHOWS TRIM VALVE FLT DECK FAULT. CONT #1 NO FAULTS. ACCOMP RESET ON #2. ACCOMP BITE VERIFY TEST ON BOTH CONT. BOTHSDR ASAA2023111146109Unknown · unknownCONT CAB ZONE TEMP ILLUMINATED. EXTINGUISHES ON MASTER CAUTION RESET. GROUNDED - YES. INTERROGATED PACK ZONE TEMP CONTROLLER FOUND TRIM VALVE FAULT. FAULT CLEARED AFTER TEST PER B737-900 FIM 21-62 TASK 801.SDR ASAA2023111146105Unknown · unknownZONE TEMP CONT CAB LIGHT ILLUMINATED ON RECALL. GROUNDED - YES. PERFORMED BITE TEST ON BOTH PACK ZONE TEMP CONTROLLERS REF FIM 21-62TASK 801.FOUND FAULT ON FLT DECK TRIM VALVE ON ZONE TEMP CONTROL #2.FAULTRESETS AND CLEARS.NO HISTORY 60 DAYS.SDR ASAA2023110846073Modulating Valve · faultyCONT CAB ZONE TEMP LIGHT ILLUMINATED UPON RECALL IT DOES RE-SET. GROUNDED - YES. (RESOLVED ON W/O: 1976139 TASKCARD: N/R-00004 ) CONFIRMED FAULT, #2 PACK/ZONE TEMP CONTROLLER SHOWS HARD FAIL "FLIGHT DECK TCV" FAULT. REMOVED & REPLACED V143 TCV REF AMM 21-61-21SDR ASAA2023110646037Unknown · unknownCONT CAB ZONE TEMP LIGHT ILLUMINATES ON RECALL EXTINGUISHES ON RESET. GROUNDED - YES. CABIN TEMPERATURE CONTROLLER BITE TEST PROCEDURE ACCOMPLISHED PER AMM 21-61- TASK 854 LEFT ZONE CONTROLLER CLEARED RED MSG. OPS GOOD.SDR ASAA2023110546008Unknown · unknownZONE TEMP CAUTION ILLUMINATED ON MASTER RECALL CHECK. EXTINGUISHED UPON MASTER CAUTION RESET. GROUNDED - YES. (RESOLVED ON W/O: 1976284 TASKCARD: N/R-00001 ) PERFORMED BITE PROCEDURE NO DEFECTS NOTED AT THIS TIME PER AMM 21-62 TASK 801 THIS REMOVES MEL 21-21G SDR ASAA2023103045913Module · malfunctionedFLIGHT DECK "ZONE TEMP" LT FALLS OUT ON DEPRESS. LH LIGHT. GROUNDED - YES. FOUND MULTIPLE "ZONE TEMP" LIGHT ASSEMBLIES LOOSE. REMOVED AND REPLACED TEMP CONTROL MODULE. OPS NORMAL. REF AMM 21-61-15.SDR ASAA2023102945880Unknown · unknownFLIGHT DECK ZONE TEMP CONTROLLER ILLUMINATED ON RECALL. GROUNDED - YES. (RESOLVED ON W/O: 1975109 TASKCARD: N/R-00003 ) PERFORMED ZONE PACK CONTROLLER BITE REF AMM 21-61-00. NO FAULTS FOUND, NO HISTORY. THI CLEARS MEL 21-21G. C/N 29023563 REMOVED. NO CONFIG CHSDR ASAA2023102945914Unknown · unknownZONE TEMP LIGHT ILLUMINATED ON RECALL AND EXTINGUISED WHEN RESET. GROUNDED - YES. PERFORMED PACK/ZONE TEMPERATURE CONTROLLER BITE TEST IAW AMM 21-61-00-700-806-002. LH & RH OPS CHECK GOOD.
Back to JASC 2160